PH20 electrode
PH20Type chart:
Model code |
Suffix Code |
option |
description |
||||
PH20 |
four-in-onePHelectrode |
||||||
material |
-F |
PVDF |
|||||
diaphragm |
-G |
Dome shaped |
|||||
cable length |
-02 |
2rice |
|||||
-05 |
5rice |
||||||
-10 |
10rice |
||||||
-20 |
20rice |
||||||
-30 |
30rice |
||||||
temperature element |
-T1 |
Pt100 |
|||||
-N-A |
Constant item -N-A |
||||||
option |
/SN3 |
stainless steel3/4 NPTConnector(316L) |
|||||
/SR3 |
stainless steel3/4NPTConnector(316L) |
||||||
/Fn4 |
PVDF 1 NPTjoint |
||||||
/FN4 |
PCDF 1 Rjoint |
||||||
/PH8 |
PH8Compliant with electrode fixing connector (only applicable for this item) |
||||||
/SF4 |
FF40,FS40andFD40Fixed component joint |
||||||
/HCNF |
HasloyNickel alloy cleaning system |
||||||
pH/ORPAnd temperature sensorsPH20andFU20type
Scope of work:
PH:2~12
Conductivity:>50uS/cm
temperature-10~100Degree(14-212℉)
Stress0-10bar(0~142PSIG)
Storage temperature:-30~50℃(-22~122℉)
feature
1. Simultaneous measurementpHandORP.
2. OverallPt1000temperature element,Improved accuracy.
3. Dual liquid junction and long diffusion path of reference electrode,More resistant to pollution.
4. Large capacity polymer electrolyte and porousPTFE(Polytetrafluoroethylene)diaphragm,Extended service life.
5. Needle shaped solid platinum solution grounding and/Or redox measurement.
6. Highly inclusive design,Make maintenance simple.
7. Directly inserted into the pipeline,Submerged or offline installation.
8. Calibration certificates issued with each sensor.
spare parts Instructions
PH20 | |
K1547QA |
/SN3stainless steel3/4NPTjoint |
K1547QB |
/SR3stainless steel3/4NPTjoint |
K1547PC |
/FN4 PVDF 1 NPTjoint |
K1547PD |
/FR4 PVDF 1 Rjoint |
K1547PE |
For composite electrodesPH8 PVDFjoint |
K1511DP |
Viton 21.9*2.62(2pcsof5deputy) |
K1511DQ |
EPDM 21.9*2.62(2pcsof5deputy) |
K1511QF |
FF40,FS40andFD40Fixed components/SF4stainless steel connector |
FU20orPH20The cleaning system |
|
K1547PJ |
*HasloyNickel alloy cleaning system(HCNF) |
K1547PF |
Nozzle and installation device(HCNF) |
K1547PH |
Nylon tubing for chemical cleaning systems(10Meter and installation kit |
detection device | |
QT20 |
PH/ORPInput simulator with transport box and cable |
connected device | |
BA10 |
PHConnection box for external cables |
WF 10-XXX-F |
With terminalPHSignal cable. The length of the entire cable |
Technical Specification-PH20
Measuring principle:pHGlass electrode and silver chloride reference system. Platinum electrode andPt1000temperature sensor
Composition materials
housing:PVDF(Polyvinylidene fluoride)
ground terminal:Solid silver
O-Circle shape:Viton
Reference liquid structure:porousPTFE(Polytetrafluoroethylene)
cable:4Core grade coaxial cable.
Functional Description(25℃time)
Isothermal point:pH7
Reference system:Containing satietyKCLofAg/AgCL
Glass impedance:200MΩ
Liquid junction resistance:1~10kΩ
temperature element:IEC 751 Pt1000
Asymmetric potential:≤15Mv
Slope:96%(Theoretical value)
note:The temperature sensor is built-inPH20Chinese,Provide indications and temperature compensation.The sealed container was not pressurized according to the factory's temperature control requirements Standard testing of force vessels.
Dynamic specification(25℃)
pHResponse time of stages(7~4):<10Reached in seconds90%
Response time during temperature stage(10℃):<3Score reached90%
stabilization time(0.02pH/10S):50uS/cm
note:Technical specifications should not be considered in isolation.For example, measuring at room temperature,pHThe scope can be expanded to0~14pH.
The unstable trend of the standard electrode shows the cumulative contamination of the reference electrode.The curve indicates that traditional electrodes have0.1~0.4pHThe error between them,ButTempressThe reading is very stable.
Example of selection:
PH20-F-G-02-T1-N-A,PH20-F-G-05-T1-N-A,PH20-F-G-10-T1-N-A,PH20-F-G-20-T1-N-A,PH20-F-G-30-T1-N-A,PH20-F-G-02-T1-N-A/SN3,PH20-F-G-02-T1-N-A/SR3,PH20-F-G-02-T1-N-A/FN4,PH20-F-G-02-T1-N-A/SN3,