Vortex flowmeter selection table:

Type spectrum

explanation

HTLUG

 

Vortex flowmeter

detection

B

 

Piezoelectric sensor

method

E

 

Capacitive sensor

connection method

1

Only applicable to full tube type

Flange connection type

2

Only applicable to full tube type

Flange card type

3

Only applicable to insertion type

Easy insertion type

4

Only applicable to insertion type

Ball valve insertion type

measuring medium

2

 

liquid

3

gas

4

steam

Nominal Diameter

2

 

DN25

…

... Unit: mm

30

DN300

Usage environment

P

 

普通型

B

Explosion-proof type

output signal

1

pulse output

2

4-20mA current output, LCD display

3

RS-485 communication

4

Battery powered, without temperature or pressure compensation

5

Integrated temperature and pressure compensation, 4-20mA current output type

6

Integrated temperature and pressure compensation, battery powered type