9210 silicon and phosphorus spectrophotometer

NegotiableUpdate on 11/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Z-09210=A=0300 9210 silicon and phosphorus meters are used in conjunction with 9210/9211 silicon and phosphorus meters.

Product Details

Z09210=A=0302

9210 silicon and phosphorus spectrophotometer


9210 silicon meter photometer

9211 phosphorus meter photometer

9210 silicon and phosphorus spectrophotometerUsed in conjunction with 9210/9211 silicon and phosphorus meters.

Testing steps for 9210 silicon meter photometer

-Enter the menu MAIN/MAINTENANCE/THE PUMPS/DAIN ON and drain the water from the measuring tank

-Enter the menu MAIN/MAINTENANCE/VALVE/VALVE 7 on to fill the measuring tank with water, close valve 7VALVE 7 off

-Open solenoid valve 1 VALVE 1 ON. Wait until the overflow cup is filled with water - enter the photometer detection menu MAIN/MAINTENANCE/HOTOMETER TEST

-When entering this menu, the sample water valve automatically opens and the sample water enters the measuring tank

-After the water in the overflow cup enters the measuring tank, press MES: At this time, the voltage value should be stable at 3500+/-20 mV

-If the voltage value is stable at this time but not 3500+/-20 mV

-Click BLACK: Its value should be 0.008+/-0.002

-Press REF: The instrument will automatically adjust the LED voltage and provide a reference voltage of 3500 mV. At this time, the LED voltage should be between 3500 and 7000

-If the LED voltage is not between 3500 and 7000 We need to clean the measuring tank.

-If the voltage value is unstable, the measuring slot should also be cleaned.

-If the voltage value stabilizes at 3500+/-20mV at this time

-Enter the menu MAIN/MAINTENANCE/THE PUMPS/PUMP 1 on and add 5 drops of R1.

-Return to the photometric detection menu Main/MAINTENANCE/HOTOMETER TEST

-Press MES and wait for 2-3 minutes.

-If the voltage value is unstable, it indicates that sodium molybdate has reacted with some impurities in the measuring tank. Therefore, the measuring tank should also be cleaned.

Spare parts for 9210 silicate/phosphate analyzer

serial number

name

Order Number

1

interface board

09200=A=5000

2

9210 silicon meter CPU board with display

09200=A=1000

3

9211 phosphate meter CPU board with display

09200=A=1011

4

power strip

09200=A=2000

5

RS 485, icult-striving completely civilized Modbus )

09125=A=0485/2485

6

92XX internal bus communication board

09200=A=5500

7

2-meter internal connecting cable/4m/7m

370=302=034/304/307

8

921X measuring board (0~1000ppb SiO2/0~5ppm-PO4)

0921X=A=1500

9

9210 silicon meter measuring board (0-5000ppb SiO2)

09210=A=1510

10

9211 Phosphorus Meter Measurement Board (0~50ppm-PO4)

09210=A=1520

11

Pipe 4 × 6 (domestically formulated)

12

Sample water solenoid valve, NPS0,8(0,2~6bar)

689=118=008

13

O-ring (flow rate adjustment screw), 4 × 1mm

14

Sample water flow rate adjustment screw

09210=A=0105

15

Sample water level detector

09210=A=0250

16

O-ring (liquid level detector), 38 × 2mm

17

Sample water solenoid valve (overflow container)

689=118=024

18

921X connection plate (mixer/heater)

09210=A=1234

19

921X mixer

09210=A=0400

20

Magnetic stirring rod

226=003=013

21

heating element

09097=C=0560

22

Pt100 temperature probe

23

921X optical cable

09210=A=0500

24

921X optical mirror

09210=C=0340

25

921X mirror spacer

09210=C=0330

26

O-ring (optical mirror), 22 × 1mm

27

Square cover (photometer cell)

09210=C=0310

28

Reagent tube, 1,6 × 3,2mm

590=050=060

29

Insert the reagent tube, 0.8 × 1.6mm

30

Reagent pump

695=114=001

31

Calibration/flushing pump

695=004=004

32

921X2 liter reagent tank

495=020=001

33

921X reagent tube countersunk head

09210=A=0600

34

9210 silicon surface chemical reagent (excluding sulfuric acid)

09210=C=7000

35

9211 Phosphorus Surface Chemical Reagent (0-5ppm PO4, without sulfuric acid)

09211=C=7000

36

9211 Phosphorus Surface Chemical Reagent (0-50ppmPO4, without sulfuric acid)

09211=C=7001

37

9210 silicon surface agent (annual dosage)

09210=A=0507