Welcome Customer !

Membership

Help

Ankerlent Instrument (Jiangsu) Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Ankerlent Instrument (Jiangsu) Co., Ltd

  • E-mail

    akltyq@163.com

  • Phone

    13347962896

  • Address

    No. 286 Tongtai Avenue, Jinhu County, Jiangsu Province

Contact Now

AKLT-PG-D Explosion proof Electric Contact Pressure Gauge

NegotiableUpdate on 01/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
1、 Overview: The explosion-proof shell of the explosion-proof electric contact pressure gauge has good explosion-proof performance. Therefore, the explosion-proof electric contact pressure gauge can withstand the explosive pressure generated by the explosive gas mixture inside the shell in the event of an explosion due to the influence of sparks or arcs during normal operation, and can effectively prevent the heat energy generated from this from propagating smoothly outward. It can only slowly diffuse outward along the small gaps of the explosion-proof joint surface inside the shell
Product Details

1、 Overview:
The explosion-proof shell of the explosion-proof electric contact pressure gauge has good explosion-proof performance. Therefore, the explosion-proof electric contact pressure gauge can withstand the explosive pressure generated by the explosive gas mixture inside the shell in the event of an explosion due to the influence of sparks or arcs during normal operation, and can effectively prevent the heat energy generated from this from propagating smoothly outward. It can only slowly diffuse outward along the small gaps in the explosion-proof joint surface inside the shell. At this point, the instantaneous temperature transmitted to the outside of the shell has dropped below the ignition temperature of the explosive gas mixture, so it will not cause detonation.
The working principle of explosion-proof electric contact pressure gauge is based on the detection element(Spring tube in measurement system)The elastic deformation of the electrical contact group is driven by mechanical transmission to produce corresponding actions of the contacts in the electrical contact group(Close or open)To enable the circuit in the voltage control system to be connected or disconnected, thereby achieving the purpose of automatic control alarm and on-site indication.
The explosion-proof category of the explosion-proof electric contact pressure gauge is Class II explosion-proof type B level T4 group, with the symbol Exd Ⅱ BT4.
Explosion proof electric contact pressure gauges are suitable for measuring the pressure of non crystalline, non solidified explosive mixtures or various non explosive media in places with explosive hazards.



2、 Structural principle:
The explosion-proof electric contact pressure gauge consists of an explosion-proof shell, a measuring system, an electric contact group, a regulating device, and an outlet box.



3、 Main technical indicators:
Accuracy level: 1.5
Scale range: 0-0.16; 0~0.25; 0~0.4; 0~0.6; 0~1; 0~1.6; 0~2.5; 0~4; 0~6; 0~10; 0~16; 0~25; 0~40; 0~60; -0.1~0.06; -0.1~0.15; -0.1~0.3; -0.1~0.5; -0.1~0.9; -0.1~1.5; -0.1~2.4MPa
Control mode: upper and lower limit slow contact switch
Maximum operating voltage: DC 220V or AC 380V;
Contact power: 10VA
Working position: Vertical installation
Environmental conditions for use: -10~50 ℃, relative humidity not exceeding 80%, and explosive mixtures should belong to Class IIB T4 or below. The working vibration and rapid pulsation of the measured medium should not affect the reliable operation of the instrument contacts.
Temperature effect: The displayed value should not exceed 0.4%/10 ℃, and the set point should not exceed 0.6%/10 ℃ (with a temperature deviation of 20 ± 5 ℃).
Insulation strength: 50Hz sine AC 2000V for one minute
Weight: 6kg



4、 Explosion proof joint surface type and its basic parameter technical data:

Instrument name Measurement range Accuracy level Contact parameters Instrument weight (Kg)
¢100 ¢150
Explosion proof electric contact pressure gauge 0 ~ 60 Mpa 1.5% Rated voltage AC380V DC220V Rated current 1A Contact power 10VA 2.1 3.2
Explosion proof electric contact vacuum gauge -0.1~ 0 Mpa
Explosion proof electric contact pressure vacuum gauge -0.1~ 2.4Mpa 2 3.1
Magnetic assisted explosion-proof electric contact pressure gauge 0 ~ 60 Mpa -0.1~ 0 Mpa -0.1~ 2.4Mpa Contact power 30VA 2.1 3.2
Explosion proof membrane box electrical contact pressure gauge 0~10~60Kpa 2.5% Contact power 10 volt ampere 2 3.1
Digital explosion-proof electrical contact pressure gauge 0~10~600Kpa0~100Mpa -0.1~ 0 Mpa -0.1~2.4Mpa 0.5% 0.25% Contact power 5A (AC250V) 1.75


Shell volumeV(L)

0.5

Joint surface type

plane

cylinder(Movable part)

Minimum effective length of explosion-proof joint surfaceLmm

15

The minimum effective length from the edge of the screw through-hole to the explosion-proof joint surfaceL1

8

The maximum gap or diameter difference of the explosion-proof joint surfaceWmm

0.15

Surface roughness of explosion-proof joint surfaceRa

3.2

1.6

Note: An example of the effective length and gap width of the explosion-proof joint surface can be found in the schematic diagram of the explosion-proof shell structure.



5、 Explosion proof shell and pressure system components and materials:

Part name

Material grade or name

Part name

Material grade or name

Drive shell cover
outlet box

ZL102
(perhapsZL-102ZL-101)

Thin gasket

L3

joint

20

shaft sleeve

QAJ9-2

Bourdon Tube

3J53

Observation window

organic glass

Note: The material of the observation window of the explosion-proof electric contact pressure gauge shall have an impact resistance strength of not less than4JOnce the observation window is damaged, it cannot be used.

Similar Product Recommend