The pressure calibrator isThe company is engaged in the production and development of new testing instruments, ,Portable pressure calibratorNot only does it solve the calibration of standard pressure, but it also better meets the comprehensive testing needs on site.
Pressure calibratorThe basic accuracy is divided into two types: 0.1% and 0.05%. It is an ideal high-end tool gauge for laboratories, factories, and colleges, and can be used as a standard gauge for medium precision pressure testing. It is an ideal pressure instrument for pressure gauges, pressure gauges, pressure transmitters, pressure switches, and other pressure instrumentsCalibration instrument.
|
● Characteristics
|
|
1. Type pressure transmitter calibratorIt is a portable instrument that can be used for both AC and DC. It can measure pressure and current, and display them on an LCD screen. It also has a 24VDC output. in additionPortable pressure calibratorA pressure hand pump is installed on the front panel, making it an ideal choiceOn site verification instrument.
|
|
2. High performance microprocessors continuously correct the zero and linearity of instruments, ensuring good repeatability and stability of zero and accuracy over a long period of time, and high measurement accuracy.
|
|
3CalibratorEquipped with an over range alarm function, when the applied pressure exceeds the rated full range+2500 words, the instrument will display OVER RANGE! P and the built-in buzzer will intermittently sound to indicate that the pressure (current) exceeds the full range. The pressurization should be stopped and some of the pressure should be removed to keep it within the specified range to avoid damaging the pressure sensor.
|
|
4. When the current measured by the calibrator exceeds 22mA, the instrument will display OVER RANGE! And the built-in buzzer will intermittently sound to indicate that the measured current exceeds the range.
|
|
5CalibratorThe software has rich content, simple and clear operation.
|
|
6. Adopting a thin film panel and imported light touch opening, the style is novel and the button life is long.
|
|
7. LCD backlight, pressure and current display, intuitive, clear, compact and reasonable structure. The pressure calibrator is small in size, light in weight, and easy to carry.
|
|
8CalibratorInstall a manual pressure generator on the front panel, with a pressure range of -90KPa to 1.6MPa, and equipped with fine adjustment and release valves. The manual vacuum rate reaches 95%, which is at the world's advanced level. The pressure source components have been finely ground and have good air tightness, meeting the IP54 sealing standard.
|
|
9. It can be directly operated on the panel to calibrate the full range.
|
|
10. Metal shell, strong anti-interference ability, firm and stamping resistant.
|
|
11. Volumetric fine-tuning makes it easy to achieve calibration point pressure.
|
|
● Technical indicators
|
|
Pressure range: -95KPa to 60MPa
|
|
Resolution: Pressure: Min 1Pa
|
|
Current: Min 1uA
|
|
Current measurement range: 0-22mA
|
|
DC output: 24VDC
|
|
Accuracy: Pressure: 0.1% F · S 0.05% F
|
|
Current: 0.05% ± 1d
|
|
Relative humidity: ≤ 80% RH
|
|
Overload capacity: 1.2-1.5 times the upper range limit
|
|
Dimensions: 300 × 150 × 110mm
|
|
Weight: 2.5Kg
|
|
Built in battery: can work for 15 hours on a single charge
model selection
|
|
|
resolution
|
negative pressure
|
accuracy
|
accuracy
|
stability
(One year)
|
hand pump
|
|
|
10KPa
|
1Pa
|
-
|
0.10%
|
0.075%
|
±0.1%F·S
|
built-in
|
|
|
16KPa
|
1Pa
|
-
|
0.10%
|
0.075%
|
±0.1%F·S
|
built-in
|
|
|
20KPa
|
1Pa
|
-
|
0.10%
|
0.075%
|
±0.1%F·S
|
built-in
|
|
|
25KPa
|
1Pa
|
-
|
0.10%
|
0.05%
|
±0.075%F·S
|
built-in
|
|
|
40KPa
|
1Pa
|
-
|
0.10%
|
0.05%
|
±0.075%F·S
|
built-in
|
|
|
60KPa
|
1Pa
|
-
|
0.10%
|
0.05%
|
±0.075%F·S
|
built-in
|
|
|
100KPa
|
10Pa
|
-
|
0.10%
|
0.075%
|
±0.075%F·S
|
built-in
|
|
|
160KPa
|
10Pa
|
-
|
0.10%
|
0.05%
|
±0.075%F·S
|
built-in
|
|
|
200KPa
|
10Pa
|
-
|
0.10%
|
0.05%
|
±0.075%F·S
|
built-in
|
|
|
240KPa
|
10Pa
|
-
|
0.10%
|
0.05%
|
±0.075%F·S
|
built-in
|
|
|
100KPa
|
10Pa
|
-95KPa
|
0.10%
|
0.075%
|
±0.075%F·S
|
built-in
|
|
|
160KPa
|
10Pa
|
-95KPa
|
0.10%
|
0.05%
|
±0.075%F·S
|
built-in
|
|
|
200KPa
|
10Pa
|
-95KPa
|
0.10%
|
0.05%
|
±0.075%F·S
|
built-in
|
|
|
240KPa
|
10Pa
|
-95KPa
|
0.10%
|
0.05%
|
±0.075%F·S
|
built-in
|
|
|
0.4MPa
|
10Pa
|
-
|
0.10%
|
0.05%
|
±0.075%F·S
|
built-in
|
|
|
0.6MPa
|
10Pa
|
-
|
0.10%
|
0.05%
|
±0.075%F·S
|
built-in
|
|
|
1MPa
|
100Pa
|
-
|
0.10%
|
0.075%
|
±0.075%F·S
|
built-in
|
|
ZP-YBS-WY
|
1.6MPa
|
100Pa
|
-
|
0.10%
|
0.05%
|
±0.075%F·S
|
built-in
|
|
|
2.0MPa
|
100Pa
|
-
|
0.10%
|
0.05%
|
±0.075%F·S
|
built-in
|
|
|
2.5MPa
|
100Pa
|
-
|
0.10%
|
0.05%
|
±0.075%F·S
|
built-in
|
|
|
4.0MPa
|
100Pa
|
-
|
0.10%
|
0.05%
|
±0.075%F·S
|
built-in
|
|
|
6.0MPa
|
100Pa
|
-
|
0.10%
|
0.05%
|
±0.075%F·S
|
built-in
|
|
|
10.0MPa
|
1KPa
|
-
|
0.10%
|
0.075%
|
±0.075%F·S
|
built-in
|
|
|
16.0MPa
|
1KPa
|
-
|
0.10%
|
0.05%
|
±0.075%F·S
|
built-in
|
|
|
20MPa
|
1KPa
|
-
|
0.10%
|
0.05%
|
±0.075%F·S
|
External
|
|
|
25MPa
|
1KPa
|
-
|
0.10%
|
0.05%
|
±0.075%F·S
|
External
|
|
|
40MPa
|
1KPa
|
-
|
0.10%
|
0.05%
|
±0.075%F·S
|
External
|
|
|
60MPa
|
1KPa
|
-
|
0.10%
|
0.05%
|
±0.075%F·S
|
External
|
|
|
100MPa
|
10KPa
|
-
|
0.10%
|
0.05%
|
±0.075%F·S
|
External
|
|
|
160MPa
|
10KPa
|
-
|
0.10%
|
0.05%
|
±0.075%F·S
|
External
|
|
|
200MPa
|
10KPa
|
-
|
0.10%
|
0.05%
|
±0.075%F·S
|
|