Detection principle of BA-50RDY fully automatic video melting point meter
The BA-50RDY fully automatic video melting point analyzer uses a capillary tube specified in the pharmacopoeia as the sample tube. The filled sample tube is inserted into the heating furnace and photographed with a high pixel camera. The TFT color screen intuitively displays the melting process of the sample. The digital imaging detection sensor automatically detects the temperature of the sample during melting.
The BA-50RDY fully automatic video melting point meter combines high-precision temperature control technology and photography technology, not only providing users with accurate, stable, and reliable test results, but also bringing users an efficient and convenient testing experience. High definition videos provide a convenient and clear view of the entire process of sample melting, with automatic detection and real-time graphical display, making it easy for users to accurately measure the melting point and dissolution distance of the sample. Fully automatic melting point meters are widely used in the chemical industry and pharmaceutical research, and are essential instruments for drugs, fragrances, dyes, and other organic crystalline substances.
Instrument features:
1. Four samples can be measured simultaneously.
2. High definition recording function, convenient for observation and review.
3. From room temperature to 400 ℃, a wide temperature range.
4. The heating rate can be infinitely adjusted at 0.1 ℃/Min-20 ℃/Min.
5. High definition color large screen enlarged window.
6. Compliant with pharmacopoeia testing methods, including the European Pharmacopoeia, the United States Pharmacopoeia, and the Chinese Pharmacopoeia.
7. Can connect to a printer to achieve real-time printing of data and printing of historical data.

Precautions for using melting point meter
Melting point determination is a fundamental means of identifying the nature of substances and is also one of the important methods for purity determination. Therefore, melting point measuring instruments play an important role in the chemical industry and pharmaceutical research, and are essential instruments for the production of drugs, fragrances, dyes, and other organic crystalline substances. The issues it pays attention to can improve the service life of the instrument.
1. The sample must be baked as required, crushed in a dry and clean grinding body, and filled firmly by tapping the capillary tube with free fall. The filling height should be consistent, and the specific requirements should comply with the pharmacopoeia regulations.
2. When inserting and removing capillaries, care must be taken to avoid breakage.
3. Different linear heating rates result in inconsistent greenhouse results, requiring the specification of certain standards.
4. Fill the tested sample with five capillary tubes at once, and take the average of the three readings in the middle as the measurement result to eliminate accidental errors caused by capillary tube and sample preparation filling.
Before inserting the capillary tube into the instrument, use a soft cloth to remove any external contaminants to prevent the oil bath from getting dirty.
If it is necessary to replace the oil bath tube, please follow the method described in the preparation work before use.