Baolun brand BL-6190 precision rotorless vulcanizing instrument, computerized rubber vulcanizing instrument, precision micro rotor vulcanizing instrument, torque rheometer

NegotiableUpdate on 03/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Overview: This machine is designed and manufactured in accordance with ASTM-D2084 and GB/T16584 standards. It measures the properties of rubber mixture as time changes at a certain temperature by synchronizing the rotor swing frequency. This property change can be seen from the torque time curve on the recorder, and can be widely used as a reference for quality in basic or development research and production lines
Product Details

overview

This machine is designed in accordance with ASTM-D2084、 GB/T16584The standard is designed and manufactured to measure the property changes of rubber mixture over time at a certain temperature by synchronizing the rotor swing frequency. This property change can be seen from the torque time curve on the recorder, and can be widely used as a reference for basic or development research and production line quality.Incoming inspection and formula improvement are indispensable testing equipment in the rubber industry!

performance parameter

Temperature control range

Room temperature -200 ℃

temperature fluctuation range

±0.15℃

Torque resolution

1/500000

Torque accuracy

0.3%

Torque unit

N.m、N.cm、N.inch、kN.m、kN.cm、kN.inch、kg.m、kg.cm、kg.inch、lp.m、lp.cm、lp.inch、g.m、g.cm、g.inch

Temperature display resolution

0.01℃

Temperature recovery time after mold closure

< 1.5min

temperature unit

C (Celsius), F (Fahrenheit), K (Kelvin)

acquisition rate

200 times/s

Supporting languages

English, Simplified Chinese, Traditional Chinese.

Using standards

GB/T 16584、ASTM D5289、ISO 6502

Calculation Parameters

ts1、ts2、t10、t30、t50、t70、t90、Vc1、Vc2

software interface

USB2.0

print contents

Date, time, temperature, vulcanization curve, temperature curve ML、MH、ts1、ts2、t10、t50、t90、Vc1、Vc2

Test standards

Compliant with ASTM D 5289, ISO6502

Frequency

100 cycles per minute (1.67Hz)

Oscillation amplitude

Standard configuration: ± 1 degree ± 0.03 degrees

[Optional] ± 0.5 degrees ± 0.03 degrees, ± 3 degrees ± 0.03 degrees

Variable temperature time

170 ℃ → 190 ℃ within 55 seconds at ± 0.3 ℃

190 ℃ → 170 ℃, reaching and within ± 0.3 ℃ within 1 minute and 40 seconds

Temperature recovery time after film lamination

The temperature compensation returns to the set temperature of 170 ℃ (with an error within ± 0.3 ℃) within 30 ± 3 seconds

heating rate

Room temperature → 170 ℃, reached within 2 minutes and 40 seconds, and remained at ± 0.3 ℃

power supply

Compressed air source

220VAC±10%, 50±3Hz;

Minimum 65psi (4.5kg/cm2)

size

L65cm x W59cmx H148cm

weight

Gross weight: 300kg, Net weight: 250kg

JCV