Welcome Customer !

Membership

Help

Shanghai Botuo Instrument Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Shanghai Botuo Instrument Co., Ltd

  • E-mail

    gaoyongli@shboqu.com

  • Phone

    18017947738

  • Address

    118 Xiuyan Road, Pudong, Shanghai

Contact Now

Botuo Instrument Ion Meter Online Analyzer - Fluoride/Calcium/Chloride Ion Meter Concentration Meter PFG-3085

NegotiableUpdate on 02/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Botuo Instrument Ion Meter Online Analyzer - Fluoride/Calcium/Chloride Ion Meter Concentration Meter PFG-3085 Botuo Instrument Ion Meter Online Analyzer - Fluoride/Calcium/Chloride Ion Meter Concentration Meter PFG-3085 Botuo Instrument Ion Meter Online Analyzer - Fluoride/Calcium/Chloride Ion Meter Concentration Meter PFG-3085 Type Online Fluoride Ion Meter Instrument Used for Industrial Ion and Temperature Measurement
Product Details
Botuo Instrument Ion Meter Online Analyzer - Fluoride/Calcium/Chloride Ion Meter Concentration Meter PFG-3085
Botuo Instrument Ion Meter Online Analyzer - Fluoride/Calcium/Chloride Ion Meter Concentration Meter PFG-3085
Botuo Instrument Ion Meter Online Analyzer - Fluoride/Calcium/Chloride Ion Meter Concentration Meter PFG-3085


PFG-3085Type online fluoride ion meter


Instrument usage

Instruments used in industryionAnd temperature measurement,aswastewater,Environmental monitoring, etc
The instrument can be installed on the panel,Wall-mounted installation,Pipeline installation
Instrument provided2Circuit current output,*The heavy load is500Ω
Instrument provided3Relay for road control,The relay can withstand a high voltage and current of5A/250VACor5A/30VDC


Product ContentWith warranty

144series product packaging,include1Taiwan Instruments, oneThis manual, fourBracket (screw),fixedblock,Fixed rod


Specifications
function Fluoride ion meter
measurement range 0.00 to 20000ppm
Measurement resolution 0.01(Less than)1ppm, zero point one(Less than)10ppm,other1ppm
Measurement accuracy ±0.01ppm,±0.1ppm,±1ppm
Voltage input range 0.0-1000.0mV
Temperature compensation method Pt 1000/NTC10K
Temperature measurement range -10.0 to +130.0
Temperature compensation range -10.0 to +130.0
Temperature resolution 0.1
Temperature accuracy ±0.2
Working environment temperature 0 to +70
Storage environment temperature -20 to +70
input impedance >1012Ω
display Large backlit dot matrixLCD
ioncurrent output1 Isolation type4to20mAoutput,*Large load500Ω
Temperature current output2 Isolation type4to20mAoutput,*Large load500Ω
Accuracy of current output ±0.05mA
RS485 Mod bus RTUStandard agreement
Communication speed 9600/19200/38400
Relay contact capacity 5A/250VAC,5A/30VDC
Cleaning settings ON1to1000In secondsOFF0.1to1000.0hour
A multifunctional relay wash/Periodic alarm/Error alarm
Relay delay action 0-120second
Data recording 50Wan Bi
Language Selection English/Traditional Chinese/Simplified Chinese
Protection level IP65
power supply 90to260VAC,power consumption<5tile
Installation method Panel installation/Wall-mounted installation/Pipeline installation
weight 144series0.85Kg, ninety-sixseries0.55Kg
function pH ORP
measurement range -2.00 to+16.00 pH -2000mVto+2000mV
Measurement resolution 0.01pH 1mV
Measurement accuracy ±0.01pH ±1mV
Temperature compensation method Pt 1000/NTC10K