Fast and accurate analysis, automated operation;
Precision gas calibration;
COInfrared detector with high resolution and reproducibilityNTheHThermal conductivity pool detector;
Using the same instrument for both melt extraction and thermal extraction;
Adjustable hot extraction analysis time;
Free choice of temperature * up to 3000 °Cabove;
Optical thermometer temperature measurement and control;
All detectors automatically reset to zero/Automatic level control(ALC);
Automatic optimization selection range for data evaluation;
Automatic cleaning of furnace and automatic injection of crucible (optional);
External computer for operation and control;
Sample information preservation;
All sample data can be traced and queried;
passFTPOr local area network for data transmission;
ON,HAnalyze and easily switch.
Brooke oxygen nitrogen hydrogen analyzer G8 GALILEO measurement range: (The measurement range can be calibrated and expanded according to the actual needs of the user))
H:0.01-1000ppm
O:0.01-5%
N:0.01ppm-3%
Diffuse hydrogen:0.05 - 1000 ml/100 g
Analysis time:
Oxygen, nitrogen, and hydrogen: approximately50s
Related to the material type and weight of the sample
power supply:
Analyzer:400V,7KVA
Peripheral devices:230V,800VA
reproducibilityOxygen, nitrogen, hydrogen:+/-0.025~0.05ppmor+/-1%relative
Specifically related to the type and weight of the sample material
carrier gas:
N2TheArpurity99.999%
Hepurity99.996%
pressure2bar
compressed air: Dry,5bar
cooling waterApproximately:4l/min
Instrument size:700 x 830x 600 mm (W x D x H)
It is easy to switch from ON analysis mode to H analysis mode through software methods
The mutual switching time between N mode and H mode only takes a few minutes
One instrument can simultaneously achieve melt extraction and thermal extraction (for diffusion hydrogen detection, an external infrared heating furnace can be optionally selected)
Can be configured with specific elements as a single element analyzer
Non contact optical temperature measurement system can detect the temperature of graphite crucible in real time
The pulse furnace has three parameter setting modes: temperature, power, and current control
The automatic sampler realizes automatic sample loading, with a 10mm injection channel to ensure safe injection of slice, block, and chip samples
The pulse furnace area has a safety protection system that the operator cannot access during analysis mode
There is an automatic monitoring system for voltage, airflow, and cooling water flow, and an independently set safety knob is used to achieve overheating protection.
Self diagnostic system is used to achieve instrument fault detection
The complete standby mode can save the consumption of carrier gas and cooling water
Bruker's universal software can easily save and retrieve analysis methods and applications, as well as set and modify parameters. Analysis data can be transmitted through FTP or local area network.
Internal gas calibration units with 10 different volumes
Automatic cleaning device
Automatic crucible switching system
The Brooke oxygen nitrogen hydrogen analyzer G8 GALILEO is equipped with an external infrared heating furnace for detecting diffused hydrogen.