| Product Introduction |
Using Sumitiomo's 4K closed-loop refrigeration system, there is no need to consume liquid helium or liquid nitrogen. The CRX-VF low-temperature vacuum probe station can provide a maximum superconducting magnetic field of 22.5KOe (2.25T) *, with a temperature range of 10K-500K. Each low-temperature sample level is equipped with a thermometer and heater, which can provide fast thermal response, quickly return to room temperature, and facilitate sample replacement. The thermal radiation screen greatly reduces blackbody radiation and improves cooling efficiency.
The system has been carefully designed to reduce vibration, using various damping devices to prevent mechanical vibrations from affecting the measurement performance. Within the full temperature range, the vibration of the sample is less than 1um (X, Y, Z axis).
The Lake Shore CRX-VF low-temperature vacuum probe station in the United States can install up to 6 micro adjustable probe arms, and the probes on each probe arm can be positioned in the 3D direction. The microwave probe can rotate ± 5 ° to better match the sample with the probe. DC probe has low noise, low leakage current, and good thermal contact. The RF probe frequency is configured to 67GHz, and the light can be incident through a window or imported through a fiber optic cable. Specialized probes are classified into various types based on size and material, reducing thermal mass and optimizing electrical contact with the device. Each probe conducts heat directly with the cold head, reducing the heat transfer from the probe to the sample.
| Product Features |
2.25T vertical superconducting magnetic field
●Adopting a closed-loop refrigeration mechanism for cooling, without the need to consume liquid nitrogen or helium, with a basic system temperature range of 10K to 350K
●High temperature option temperature range: 20K to 500K
●The probe arms are heat sunk on the radiation shielding screen and sample stage, with a minimum temperature of 25K
●Install temperature sensors on the probe arm for temperature monitoring
●Temperature control stability: ± 50mK
●Low vibration design: in sample stage<1 μ m (X, Y, Z axis)
●Measure DC to 67GHz
●Various sample racks are suitable for low-noise, high-frequency, and high impedance measurements
●Maximum test sample size 51mm (2in) diameter
●Up to 6 probe arms can be used