CX-9000 direct reading spectrometer

NegotiableUpdate on 09/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Product Overview: 1. The manufacturing technology channel of the second-generation CCD/CMOS full spectrum spectrometer is not limited; 2. Upgrading multiple substrates is convenient, without the need to change or add hardware; 3. Excellent data stability, analyzing the same sample at different time periods can achieve good data consistency

Product Details

Product Overview

1. The manufacturing technology channel of the second-generation CCD/CMOS full spectrum spectrometer is not limited;
2. Upgrading multiple substrates is convenient, without the need to change or add hardware;
3. Excellent data stability, good data consistency can be obtained by analyzing the same sample at different time periods;
4. Small size, light weight, easy to move and install;
5. High integration, high reliability, and high stability;
6. High cost-effectiveness;




Main Features



1. Can determine various elements of various non-ferrous metals,Suitable for various metal substratesFor example: aluminum based, copper based, zinc based. Full spectrum technology covers the entire range of elemental analysis and allows for the selection of channel elements according to customer needs;
2Fast analysis speedMeasure the elemental composition of all channels within 20 seconds. By setting pre ignition time and markings for different analytical materials, the instrument can achieve optimal analysis results in a short amount of time;
3. The optical system adoptsConstant temperature light chamberThe arc flame generated during excitation is directly introduced into the light chamber through a lens, achieving direct optical path transmission, eliminating optical path loss, improving detection limit, accurate measurement results, good reproducibility, and long-term stability;
4. SpecialOptical chamber structure designSmall size and light weight;
5Automatic optical path calibrationThe optical system automatically performs spectral line scanning to ensure correct reception and eliminate tedious peak scanning work. The instrument automatically recognizes specific spectral lines, compares them with the original storage lines, determines the drift position, and finds the current pixel position of the analysis line for measurement;
6. Open electrode holder design, adjustable sample holder for easy accessAnalysis of samples of various shapes and sizes
7. The working curve adopts international standards, and a pre made working curve is used,Can be extended and expanded as neededEach curve is generated by exciting up to dozens of standard samples, and interference is automatically deducted;
8HEPS digital solid-state light sourceAdapt to various materials;
9. Copper fireworks table base,Improve heat dissipation and durability
10. Reasonable argon gas path design reduces the flushing time of argon gas during sample excitation, providing users with benefitsSave argon gasThe consumption of argon gas is less than half of that of a regular spectrometer;
11. Using tungsten material electrodes, the electrode has a longer service life and is designed withElectrode self blowing functionCleaning electrodes is easier;
12. High performance DSP and ARM processor, with high-speed data acquisition and control functions and automaticReal time monitoring of chamber temperature, vacuum degree, argon pressure, light source, excitation chamber, etcThe operational status of the module;
13. Ethernet connection is used between the computer,Good anti-interference performanceExternal computer upgrades are not related to instrument configuration, making the instrument more adaptable;
14All core components are imported with original packagingEnsuring the quality of the instrument.





parameter indicators




CX-9000 direct reading spectrometer
Flat field optical system
Automatic control constant temperature: 35 ℃± 0.5 ℃
200-500nm
350 mm
25.4mm
2160 l/mm
1.2 nm/mm
Multiple high-performance linear array CCDs
10pm/pixel
Argon flushing type
When activated, 3-5L/min; when in standby mode: no standby flow required
Tungsten material jet electrode technology
Click on the self blowing function
Thermal deformation self compensation design
Sample stage analysis gap: 4mm
HEPS solid-state light source
100-1000Hz
1-80A
Optimization design of discharge parameters
HEPS
High end ARM processor, high-speed data synchronization acquisition and processing
Ethernet data transmission based on DM9000A
220VAC/50Hz
700W during analysis, 40W in standby mode
10-30 ℃ (temperature variation within this temperature range is not greater than 5 ℃/h)
20-80%




Product Application



The CX-9000 full spectrum direct reading spectrometer is a product specifically designed for the analysis of non-ferrous metal materials, developed with European technology and internationally recognized advanced CCD/CMOS spectrometer technology.
This product is widely used inProduction process control, furnace testing, and central laboratory finished product inspection in metallurgy, casting, machinery, automobile manufacturing, aerospace, weapons, metal processing, and other fields.
The CX-9000 full spectrum direct reading spectrometer is an ideal choice for controlling product quality due to its small size, good stability, low detection limit, fast analysis speed, low operating cost, and easy operation and maintenance.