The NexION 350 ICP-MS is designed to improve the efficiency of elemental analysis laboratories, particularly providing the most accurate characterization tool for the field of nanoparticle analysis, with maximum sample flux, minimum downtime, and optimal instrument design. The NexION 350 features extraordinary three cones and three
Maximum sample flux, minimum downtime, optimal instrument design
The NexION 350 ICP-MS is designed to improve the efficiency of elemental analysis laboratories, particularly providing the most accurate characterization tool for the field of nanoparticle analysis. The NexION 350 optimizes instrument design through extraordinary triple cone, triple quadrupole, and three working modes innovative technology, reducing background and interference, optimizing signal stability, thereby maximizing sample flux and minimizing downtime. The combination of these functions can enable laboratory professionals to run more samples per unit time, providing the strongest instrument utilization efficiency, optimizing instrument workflow, and making you and your laboratory more efficient. The NexION 350 can collect 100000 data points per second, which is more than 10 times faster than any other ICP-MS on the market. This collection rate is ideal for applications that require fast instantaneous data collection and analysis, such as nanoparticle characterization, morphology analysis, and laser ablation, ensuring that critical information is not lost. The NexION 350 specialized nano application module - Syngistix, provides unprecedented levels of nano detection and characterization. By implementing various functions with NexION 350, professionals in rapidly developing nanomaterial science laboratories can significantly improve the experimental process, such as obtaining particle composition analysis and concentration while also obtaining particle size distribution information. These results can all be obtained directly in a single run, in less than a minute, without the need for heavy manual calculations.
long-term stability
PerkinElmer's design philosophy emphasizes long-term stability, not only the stability achieved during instrument acceptance for 2 or 4 hours, but also the stability of actual samples (high salt content, or large amounts of organic matter), as well as the stability of the instrument after 15 or even 20 years of use.
Unparalleled stability creates extraordinary productivity
NexION ICP-MS utilizes a series of technological innovations to reduce background and interference, optimize signal stability, reduce maintenance requirements and downtime, and achieve better results.
The three cone interface produces the industry's most compact focused ion beam and prevents sample deposition on internal components
Four stage rod ion deflector guides positively charged ions
90 degree deflection to the universal pool and filtering of neutral particles
Maintenance free ion lens
Path design that brings more accurate results
The unique ion pathway of NexION 350 ICP-MS provides the cleanest and most stable environment, providing the instrument with more accurate and stable test results. From powerful sample introduction systems to industry-leading detectors, each component is carefully designed for easier use, optimal performance, and optimal laboratory efficiency.
Triple cone interface
In addition to the typical sampling cone and truncation cone found in other systems, the NexION 350 ICP-MS also features a unique super truncation cone for obtaining the most tightly focused ion beam. The unique three cone interface reduces the pressure between them, ensuring smaller ion dispersion and preventing sample deposition on the inner wall. No need to adjust the voltage, all three cones are outside the vacuum zone, so they can be quickly and easily disassembled, cleaned and replaced for easier maintenance, while reducing downtime. The unique three cone interface ensures sensitivity and stability. Compared to other instrument systems, the maintenance of this instrument is faster and simpler.
Quadrupole Ion Deflector
As the first of the three four stage rods in the NexION 350 ICP-MS, the four stage rod ion deflector forms a powerful supplement to the three cone interface, enhancing stability and eliminating drift. It has a groundbreaking filtering function that deflects the ion beam 90 degrees before entering the patented universal pool and four stage rod, providing unparalleled stability, reducing background and interference, and obtaining the most accurate results. The four stage rod ion deflector is unique among similar filters, allowing you to achieve optimal analysis conditions for each element in one analysis by automatically adjusting the mass bandwidth during ion flight.
Align the path of the four stage rod ion deflector closely with the ion beam leaving the three cone interface. This ensures that ions and neutral particles never come into contact with the surface of the component, ensuring cleanliness and providing additional signal stability, even when operating the most complex substrates continuously. The efficient focusing of the three cone ion beam and the fully aligned design with the four stage rod ion deflector completely eliminate the necessary extraction lens, reduce maintenance requirements, and prevent high background equivalent concentration (BEC), resulting in a more stable and consistent analysis environment.
This instrument can effectively eliminate non ionized substances and is the only ICP-MS that can provide maximum instrument operating time and quick investment recovery without the need for cleaning or replacing the tank.