XY-8000Carbon steel element analyzerWorking Principle:
The operation of the instrument is based on the basic principle of atomic emission spectroscopy analysis: when various elements that make up a substance are excited by a light source, they will emit characteristic spectra of each element. The intensity of spectral lines has a certain functional relationship with the content of elements. If the intensity values of each element's spectral lines are measured, the content of that element in the substance can be calculated.
XY-8000Carbon steel element analyzerTechnical Indicators:
1. Excitation light source
Supply voltage: 50Hz 200V ± 1%
Input power: 1.0Kva
Charging capacitor: Pre burned at 6 μ F and exposed at 1.5 μ F
Peak current: Pre burning 120A, exposure 30A
Main circuit peak voltage: 300VDC (using automatic peak voltage adjustment)
Ignition circuit: pulse amplitude+15kV
Auxiliary gap: tunnel diode is used
Discharge frequency: 400Hz (optional 150-500Hz)
Sample stage analysis gap: 4mm
2. Spectrometer
Analysis band range: 160-450mm
光 栅:曲率半径750mm
Engraving density: 2400 lines/mm
Engraving area: 30 * 50mm ²
Sparkling wavelength (first level): 300nm
Linear dispersion: 0.55nm/mm
Incident slit width: 20 μ m
Exit slit width: 50 μ m, 75 μ m
Allow maximum multi-channel: 31
Local constant temperature of spectrometer: 35 ℃± 0.5 ℃
3. Measurement and Control System
Measurement and control system: using a single board computer for measurement and control, and exchanging data with the upper computer
Measurement method: segmented integration
Integral capacitance: 0.047 μ F or 0.1 μ F
4. High voltage power supply for photomultiplier tube:
Stability: When there is a change in the load, the output change is less than 0.005%, and when there is a 20% change in the line, the output change is less than 0.003%;
High voltage regulation: varies from -550V to -1000V, divided into 8 levels of adjustment, with each level adjusted to 70V;
High voltage setting: Users can change it through computer software.
XY-8000Carbon steel element analyzerDetection range:
C:0.0025-4.0% Si:0.0008-5.0% Mn:0.001-23.0% P:0.001-2.0%
S:0.001-0.35% Cr:0.001-35.0% Ni:0.001-45.0% Mo: 0.001-10.0%
Pb:0.001-0.4% Bi:0.002-0.1% W:0.005-22.0% Ti:0.0005-3.0%
Al:0.001-9.0% Sn:0.001-3.0% Sb:0.002-0.2% As:0.001-0.1%
Mg:0.001-0.2% La:0.005-0.50% Co:0.001-2.5% Zn:0.003-0.05%
Nb:0.005-3.0% Cu:0.001-7.5% B:0.0005-0.1% Ce:0.002-0.1%