After establishing the standard curve inside the instrument, the testing of the sample can be carried out.
XY-FCtypeCopper alloy composition analyzer parameters:
1Wavelength range: 400-750mm
2Range of absorbance: 0-2A
3Concentration range: 0.000-99.99% Automatic shift display
4Reproducibility: better than 0.003A (at 0.5A)
5Key form: Touch film keyboard with 32 keys and audio prompts
6Display method: 5-digit LED digital display (1-digit indicator, 4-digit significant decimal point automatically switches) Three channels display 3 × 5 digits respectively
7Data storage: EPROM, power-off data can be saved for 10 years
8Power supply: AC 220V ± 10% 50Hz ± 5%
9. Power consumption: ≤ 50W
10Dimensions: (580 × 280 × 230) mm
11Weight: 15kg
Test steps:Price of copper alloy composition analyzer
(1) After the power supply of the internal standard curve is turned on, the curves used in each channel are all curve 1. If you want to use another standard curve, follow the curve (the displayed curve is for channel *, and the channel value is the curve number. After selecting channel *, jump to the second channel, select the corresponding curve number, and press exit to execute).Price of copper alloy composition analyzer
(2) After the self calibration zero and full power are turned on and stabilized for 10-15 minutes, a self calibration zero and full must be performed to ensure the accuracy of the test. (The method of adjusting the full degree is to press the full degree knob on the touch switch when the three colorimetric cups are filled with distilled water, while zeroing is usually done automatically by the instrument. The manual zeroing method is to press the TAC value knob on the panel. When U is displayed in front of the digital tube, press the zeroing knob on the back of the instrument.)
(3) The reading and printing of the sample: After injecting the sample solution into the colorimetric cup, wait for the solution to be relatively stable and no bubbles to escape before reading. The symbol bit of this channel displays "C", and the values displayed on the other digital tubes are the percentage concentration values of the measured element content of the sample. If printing is required, simply press' print n '(n=1-3, channel number) to print out the data for the corresponding channel.