Welcome Customer !

Membership

Help

Dalian Yiste Technology Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Dalian Yiste Technology Co., Ltd

  • E-mail

    1534513049@qq.com

  • Phone

    15566891672

  • Address

    No. 38, West Section of Century Road, Pulandian District, Dalian City, Liaoning Province

Contact Now

Circulating residual chlorine analyzer

NegotiableUpdate on 01/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The YST909B-CH980 device, as the core equipment for continuous monitoring of residual chlorine content in water bodies, has become a monitoring tool in the field of water treatment due to its real-time and stability advantages. This device is also a representative model of our circulating residual chlorine analyzer, with a market guidance price of 5500.0 yuan. Due to different parameter configurations, the actual transaction price may vary. This article will comprehensively analyze the functions, advantages, and application value of the YST909B-CH980 device from the core dimension of the product.
Product Details

Dalian Yister YST909B-CH980 Equipment: Principle, Application, and Development Overview Analysis

Residual chlorine is a key indicator after water disinfection, which directly affects water quality safety and usage effectiveness. The YST909B-CH980 equipment launched by Dalian Yister, as the core equipment for continuous monitoring of residual chlorine content in water bodies, has become a monitoring tool in the field of water treatment due to its real-time and stability advantages. This equipment is also under our umbrellaCirculating residual chlorine analyzerThe representative model has a market guidance price of 5500.0 yuan, and the actual transaction price may vary due to different parameter configurations. This article will comprehensively analyze the functions, advantages, and application value of the YST909B-CH980 device from the core dimension of the product.

1、 Product Introduction: What is YST909B-CH980 Equipment

YST909B-CH980 equipment passedContinuous collection of water samplesReal time detection of residual chlorine (including free residual chlorine and compound residual chlorine) concentration in water using electrochemical or optical principles. Its core feature is the "circulation type" design, which means that the water sample continuously flows through the detection unit at a set flow rate, without the need for manual sampling, and can achieve 24-hour uninterrupted monitoring. The data is directly output through the display screen or transmission system, providing real-time data support for water quality control.
Compared with offline detection methods such as laboratory titration, the YST909B-CH980 equipment does not require manual intervention and can avoid errors in the sampling process. It is more suitable for scenarios that require long-term and dynamic monitoring of residual chlorine changes,Circulating residual chlorine analyzerThe role of YST909B-CH980 is particularly crucial, and our equipment is developed and designed based on this requirement.

2、 Advantages and Characteristics: Why Choose YST909B-CH980 Equipment

The core advantages of the YST909B-CH980 equipment revolve around "efficiency, stability, and ease of use", which can be divided into the following four points:
  1. Real time monitoring, rapid responseContinuous circulation detection of water samples, with fast data update frequency (usually seconds or minutes), can timely capture fluctuations in residual chlorine concentration and avoid water quality risks caused by lag.

  1. Low operation and maintenance costs, easy to operateThe device comes with an automatic cleaning function, reducing the frequency of manual disassembly and cleaning; The interface is for visual operation, and parameter settings and daily maintenance can be completed without professional skills.

  1. Strong environmental adaptabilityIt can adapt to different water temperatures (0-50 ℃) and water pressure conditions (0.1-0.6MPa), and has anti-interference design, which can operate stably in turbid water and scenarios containing trace impurities.

  1. Data traceability for easy integrationSupport data storage (local or cloud), can export historical curves; Simultaneously equipped with standard signal output (4-20mA analog signal, RS485 digital signal), it can be connected to the central control system of the water plant and the smart water management platform to achieve integrated management and control.

3、 Technical parameters: Core performance indicators of YST909B-CH980 equipment

The following are the core parameter configurations of the YST909B-CH980 equipment, and different parameter combinations will affect the equipment price:
parameter category
Specification Range
measurement range
0-5mg/L, 0-10mg/L (customizable)
Water sample conditions
Temperature: 0-50 ℃; Pressure: 0.1-0.6MPa
Water sample flow rate
100-500mL/min (adjustable)
output method
4-20mA analog signal, RS485 digital signal
Power supply requirements
AC 220V±10% 50/60Hz
Installation method
Wall mounted, pipeline mounted, and disc mounted
Protection level
IP65 (indoor), IP67 (outdoor optional)

4、 Selection criteria: How to match YST909B-CH980 equipment with its own needs

Selection needs to be combined withApplication scenarios, water quality conditions, and system integration requirementsThe three core factors can be referred to in the following four points:
  1. Select adaptability based on water quality complexityIf the water body is turbid (such as effluent from sewage treatment plants or river water), the customized YST909B-CH980 model with pre-treatment unit (such as filtration device) can be selected; If it is a clean water body (such as a water plant or water purification plant), the basic configuration of YST909B-CH980 can meet the demand.

  1. Select response speed based on monitoring frequencyFor scenarios such as thermal heating and hospital wastewater that are sensitive to residual chlorine fluctuations, the YST909B-CH980 model with a data update frequency of ≥ 1 time/minute can be selected; For scenarios with small fluctuations such as municipal pipeline networks, conventional response speed configurations can be selected.

  1. Select output interface based on system integration requirementsIf you need to connect to the smart water platform, you can confirm whether the YST909B-CH980 model supports the required communication protocol (such as Modbus); If viewed locally only, the basic 4-20mA signal output configuration is sufficient.

  1. Choose protection and installation methods based on the installation environmentOutdoor installation (such as river monitoring points) can choose the YST909B-CH980 model with IP67 protection level; Pipeline type is preferred for installation next to pipelines, while disc type can be selected for the central control room.

5、 Application industry: YST909B-CH980 equipment covers multiple fields of water treatment scenarios

The application of YST909B-CH980 equipment runs through the entire chain of "water supply water drainage", especially playing a core role in the following 10 industries:
  • waterworksMonitor the residual chlorine concentration in the factory water to ensure that there is still disinfection ability during pipeline transportation and prevent secondary pollution.

  • Water purification plantReal time control of residual chlorine in terminal water for direct drinking water and bottled water production, balancing disinfection effectiveness and taste.

  • sewage treatment plantMonitor the residual chlorine in the effluent of disinfection units (such as ultraviolet and chlorine disinfection) to ensure compliance with discharge standards and avoid affecting the receiving water body.

  • Municipal water supply networkInstall intermediate pump stations and end water intake points in the pipeline network, monitor the decay of residual chlorine, and adjust the disinfection strategy of the pipeline network in a timely manner.

  • Environmentally Friendly Water TreatmentUsed for centralized sewage treatment stations in industrial parks to monitor residual chlorine in external drainage, in compliance with environmental discharge standards.

  • Thermal heatingDetect residual chlorine in heating circulating water to prevent corrosion of the inner wall of the pipeline, the growth of microorganisms, and extend the service life of the pipeline network.

  • Hospital wastewater treatmentHospital wastewater contains a high amount of bacteria, and residual chlorine monitoring is necessary to ensure disinfection effectiveness and prevent the spread of bacteria.

  • Chemical wastewater treatmentPart of the chemical wastewater needs to be disinfected with chlorine before discharge, and the equipment can control the residual chlorine concentration to prevent excessive chlorine from interfering with subsequent treatment units.

  • River water quality monitoringInstalled at the mouth of river channels and around drinking water sources to monitor residual chlorine input from external sources and assess its impact on river ecology.

  • Smart rural water managementReal time monitoring of residual chlorine in peripheral water for rural centralized water supply projects to ensure the safety of drinking water for rural residents.

6、 Technology Trend: Future Development Direction of YST909B-CH980 Equipment

With the upgrading of the water treatment industry towards "intelligence and integration", our Dalian Yister presents three major directions for the technological development plan of the YST909B-CH980 equipment:
  1. Intelligent upgradeIntegrated AI algorithms can automatically identify abnormal data (such as sudden rise and fall of residual chlorine) and trigger warnings; Support remote control (such as remote calibration and parameter adjustment) to reduce on-site operation and maintenance workload.

  1. Multi parameter integrationFrom single residual chlorine detection to multi parameter synchronous monitoring of residual chlorine+pH+turbidity+temperature, multiple water quality indicators can be obtained in one sampling, reducing equipment installation costs.

  1. Low energy consumption and environmental protectionAdopting low-power chips and energy-saving design, compatible with solar power supply (suitable for outdoor river monitoring); Upgrade consumables (such as reagents and electrodes) to environmentally friendly ones to reduce the impact of waste on the environment.

7、 User evaluation: Feedback from customers in various industries on the YST909B-CH980 equipment

The following evaluation is based on real usage scenarios of customers in various industries:
  • Sewage treatment plant customersPreviously, manual detection of residual chlorine required running three times a day. Now, the YST909B-CH980 equipment from Dalian Yister has been installed, and the data is transmitted in real-time to the central control, saving a lot of manpower and enabling timely detection of insufficient disinfectant dosage. ”

  • Hospital wastewater treatment clientsThe disinfection requirements for hospital wastewater are strict. The YST909B-CH980 equipment is monitored 24 hours a day. Once the residual chlorine does not meet the standard, an alarm will be triggered, so there is no need to worry about data being unqualified during environmental inspections. ”

  • Municipal pipeline network customersThe residual chlorine at the end of the pipeline network is prone to decay. After installing the YST909B-CH980 equipment, it can accurately determine which area needs chlorine replenishment, which is more scientific than adjusting based on experience before. ”

  • Thermal heating customersPoor control of residual chlorine in circulating water can corrode pipelines. After using the YST909B-CH980 equipment, the residual chlorine stabilized within a reasonable range and the number of pipeline repairs was significantly reduced. ”

8、 Application case: Actual scene landing effect of YST909B-CH980 equipment

Case 1: Monitoring of residual chlorine in municipal pipeline network

  • industryMunicipal water supply network

  • demandThe municipal pipeline network in a certain city has a wide coverage area, and end users (such as suburban communities) often experience insufficient residual chlorine. It is necessary to accurately locate low residual chlorine areas.

  • SolutionA total of 12 Dalian Yister YST909B-CH980 equipment were installed at the pumping station in the middle of the pipeline network and the water inlet of suburban communities, and the data was transmitted in real-time to the central control platform of the Municipal Water Group.

  • effectThrough data analysis, three pipeline sections with severe residual chlorine decay were identified, and targeted chlorine replenishment points were added. The compliance rate of residual chlorine in the end water increased from 85% to 99%.

Case 2: Hospital wastewater disinfection monitoring

  • industryHospital wastewater treatment

  • demandThe wastewater treatment station of a tertiary hospital adopts sodium hypochlorite disinfection, and it is necessary to ensure that the residual chlorine in the discharged water meets the "Discharge Standards for Water Pollutants in Medical Institutions" (GB 18466-2005).

  • SolutionInstall Dalian Yister YST909B-CH980 equipment at the outlet of the disinfection unit, and set the alarm threshold (alarm when it is below 0.5mg/L or above 1.0mg/L).

  • effectThe equipment has been running for 1 year without exceeding or failing to meet residual chlorine standards. It has passed environmental testing multiple times and reduced the waste of sodium hypochlorite.

Case 3: River estuary monitoring

  • industryRiver water quality monitoring

  • demandThere are three industrial park sewage treatment plants around a certain river channel, and it is necessary to monitor whether the residual chlorine in the treated water has an impact on the river ecology.

  • SolutionInstall one Dalian Yister YST909B-CH980 equipment at each of the three sewage treatment plant inlet ports, and synchronize the data to the local environmental protection bureau monitoring platform.

  • effectDiscovered occasional excessive discharge of residual chlorine (>0.2mg/L) from one factory, promptly urged rectification to avoid toxic effects on river fish and shrimp.

Part of the content is generated by AI and is for reference only. Please contact our sales personnel if needed.
Similar Product Recommend