Shenzhen Fiteli Technology Co., Ltd. is an agent and general agent in China for the rapid detection of coliforms, fecal coliforms, Escherichia coli, and Escherichia coli. The global high-quality rapid detection instrument for coliforms, fecal coliforms, Escherichia coli, and Escherichia coli was jointly developed by the Institute of Physics at the University of Rome, the Italian Institute of Nuclear Physics (INFN), and the Institute of Biology at the Third University of Rome. It can completely replace the high-tech crystallization of traditional microbiology laboratories.
Product Details

Welcome to telephone consultation or online inquiry!
Coliform group, fecal coliform group, Escherichia coli and Escherichia coli rapid detection instrument
German RBG
RVLM

Measurement time: inversely proportional to bacterial content
Power supply: 220V
Dimensions: 300 * 200 * 100 (mm)
Weight: 2.5 (kg)

【 Main Features 】

*1.Quantitative detection of foodborne pathogenic bacteria and total bacterial count

*2.Can detect solid, liquid, surface, paste, and slurry samples

*3.Instrument detection principle: ensemble culture dish method, enzyme method (β)-Glucosidase analysis, * * method (antigen search), and gene method (gene search)

*4. 8Each detection position is independently operated to meet the needs of detecting different samples and microorganisms.Each detection bit is independent.

*5.To detect more samples, multiple machines can be connected to the same computer for use,

*6.Can automatically select and control the temperature of inspection items;

*7.Software applicableJAVAenvironment

*8.Can be connected to the internet, with2.0USBinterface

*9Simultaneous detection of three light waves (blue, green, red)

*10.Automatically generate quantitative analysis report after the detection is completed

*11.If the lid is folded during operation, the analysis will automatically stop, equipped with a light wave protection safety device.

*12.The sample does not require any pre-treatment process during detection, it can be directly thrown into the detection bottle

*13.Testing samples only requires1ml/1g

*14.Sensitivity up to detectable1Target microorganisms;

*15.High specificity99.999%

*16.Three simple operation steps, foolproof, no need for professional operators;

*17The instrument is portable and can be used for testing anytime, anywhere100%Quantitative analysis, and can be directly connected to a computer to generate quantitative analysis and testing reports.

*18Through authoritative certificationISO 161402003Certification of the Alternative Method for Microbiology of Food and Animal Feed,comply withISO/IEC 17025:2005Standard internal certification

[Scope of Detection]
Total number of live bacteria
coliform bacteria
Escherichia coli (including all pathogenic Escherichia coli O157, O111, O104, O145, etc.)
Enterobacteriaceae

Staphylococcus aureus
Pseudomonas aeruginosa
Salmonella
Listeria
Enterococcus(Streptococcus)
Reduction of sulfite Clostridium difficile
Clostridium difficile
**Class(For example: Aspergillus, etc)
yeast(For example: yeast)

[Scope of Application]
Hygiene control:

-Food(HACCP

-Kitchen, tools, surfaces(HACCP

-water quality

-(CDC)**Control, import and export inspection and quarantine

-Medicines and cosmetics

It is closely related to our lives, for example:

Coffee shops, restaurants

Water source testing, water treatment plant

Analysis laboratory andHACCPdiagnosis

Agricultural products and related processing companies

Pharmaceutical factories, pharmacies, cosmetics factories

Environmental monitoring agencies

水配送公司

Consumer protection groups, business management agencies

Indoor air conditioning regulation company

Combining the advantages of traditional inspection methods:

-Petri dish method

-Enzymatic method (β)-Glucosidase analysis

**Law (Antigen Search)

-Genetic method (gene search)

No pre-treatment is required for sample testing

-Liquid samples, solid samples, and surface samples do not require pre-treatment

qualitative and quantitative analysis

-Paired with testing machine:100%Quantitative analysis

-Visual interpretation: qualitative or semi quantitative analysis

Simple and convenient

-Three simple steps to obtain detection results

Quick inspection

-It is the speed of traditional inspection methods25times

high sensitivity

-Can detect1Target microorganisms (theoretical extremum)

high specificity

-High specificity99.999%(Theoretical extremum)

The testing bottle is the laboratory

-Microbial testing bottles are available at any time

-Testing personnel who have not received strict professional training can also conduct testing anytime and anywhere

Safely dispose of after use

-Handle the same as expired * *

Testing steps:

(Obtained in three simple steps)100%Quantitative testing results

**Step: Put in the sample

-Open the bottle cap and add11mlsterile water

-Put in liquid (solid)/Surface Sample0.1~1.0ml0.1~1.0g

-Tighten the bottle cap tightly

**Step: Shake the bottle until the solvent is fully dissolved or mixed

(Fully dissolve or mix as shown in the figure on the right)

-If an oscillator is used, it takes time20秒左右;

Or shake vigorously with your hands, it takes time2~3About minutes.

Step 3: Read the results at an appropriate time (please refer to the table on the right)

-useRVLMMicrobial detector:

-After fully dissolving and mixing, immediately put it into the detector
-get100%Quantitative analysis results

if notRVLMMicrobial detection equipment onlyRVLWhen testing bottles:

-After fully dissolving and mixing, incubate in a thermostat

(Incubate at an appropriate temperature for an appropriate period of time, please refer to the table below)

-Visual interpretation of qualitative or semi quantitative analysis results

Taking Escherichia coli as an example:

If the number of bacterial colonies is greater than108CFU/ml2The color turns yellow within an hour;

If the number of bacterial colonies is less than102CFU/ml14The color will not turn yellow within an hour;

If the colony does not exist:18After hours, the color still maintains its initial color

Or other intermediate colors (not turning yellow)

Aseptic treatment after use

-pressRVLAbove the cap of the microbial detection bottle

-Safely dispose of with peace of mind (treated the same as expired * *)








Product after-sales service

We have experienced technical engineers and professional management and marketing talents who can provide * suitable products and * professional services according to customer needs. Our service philosophy is: Fitly is dedicated to meeting your needs!
Coliform group, fecal coliform group, Escherichia coli and Escherichia coli rapid detection instrumentWorth it! Welcome to call for consultation!

【 Related Information 】
Microbial detection bottle
Yeast rapid detection bottle
Escherichia coli rapid detection bottle
Salmonella rapid detection bottle