1DC resistance testerKey Features:
◆The whole machine is composed ofhigh-speedSingle chip microcontroller control, automaticHigh degree of transformation,Easy to operate.
◆The instrument adopts a new power supply technology with a wide measurement range.
◆guaranteeThe protection function is complete and can reliably protect against the impact of back electromotive force on the instrument,More reliable performance.
◆Fast response speed,The instrument measurement data is stable,instrumentDuring the testing processAuto Refreshdata.
◆Intelligent power management technology,The instrument always operates at its minimum power state,Effectively reduce internal heating of the instrumentSave energy.
The instrument is equipped with a non power-off clock inside.
The instrument has an internal non power down memory that can store data.
IIDC resistance testerRated parameters:
Measurement range:
| current range | measurement range |
| <5mA | 30Ω-50KΩ |
| 100mA | 500mΩ-80Ω |
| 300mA | 100mΩ-25Ω |
| 1A | 50mΩ-8Ω |
| 5A | 1mΩ-0.4Ω |
| 10A | 0.5 mΩ-200 mΩ |
◆Output current: automatic10AThe5AThe1AThe300mAThe100mAThe<5mA
◆ Resolution:0.1μ Omega
◆Accuracy: 0.2%
◆ Open voltage: 5A, 10A gear: 2.5V; Other gear: battery voltage;
Output power: 25W
Working temperature: 0~40 ℃
◆ Working humidity:<90% RH, no condensation
◆ Dimensions: Length 230mm X Width 155mm X Height 60mm
Weight: 1.2kg
IIINotes:
◆Connect the test clip. After connecting the test clip to the lead out end, twist the test clip a few times with force to cut through the oxide film to ensure a good connection.
If the contact end is exposed to air for a long time, the surface will be covered with an oxide film, which may cause unstable or inaccurate measurement results.
◆Before disconnecting, be sure to wait for the instrument to reset and there to be no current output. After the discharge is complete, turn off the power before disconnecting.
◆When selecting the current, refer to the range in the technical specifications column and do not use it beyond or below the range.
4Configuration List:
| item name | quantity |
| DC resistance testerhost | 1 unit |
| 10A type test line | 1 set |
| Charger DC12.6V2A | 1 piece |
| Standard resistance | 1 piece |
| protect the backpack | 1 piece |
| Instruction Manual | 1 book |
| Certificate of Conformity | 1 copy |
| Factory Inspection Form | 1 copy |