DC voltage monitoring device with multiple output circuit monitoring 485 communication

NegotiableUpdate on 12/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The AMC16Z-FD series DC voltage monitoring device launched by Ankerui is a multi outlet circuit monitoring 485 communication device. It is one of the AMC16Z series DC precision distribution monitoring devices, mainly used to monitor the full power parameters of the A+B dual DC outlet 16 branches.
Product Details

AMC16Z-FD is a type of DC precision distribution monitoring device in the AMC16Z series of Ankerui company,Mainly used to monitor the full power parameters of 16 branches of A+B dual DC output lines.It is mainly used to monitor the full power parameters of 16 branches of A+B dual DC output lines.

Its application scenarios mainly include the following aspects:


  • data centerThe data center needs to carefully monitor the power consumption of each branch of the server rack cabinet (PDU) to ensure balanced power supply and provide early warning. AMC16Z-FD can manage the power supply of data center servers and monitor real-time full power parameters such as current, voltage, and power of 24 branches of A+B dual DC output lines, helping data centers achieve sub item energy consumption analysis, timely detect abnormal loads, optimize power consumption structure and operation strategies.

  • New energy factoryIn new energy factories, real-time energy flow monitoring is required between photovoltaic, energy storage, and DC loads to achieve energy efficiency management. AMC16Z-FD can monitor the DC power supply system in new energy factories, and provide data support for energy efficiency management by real-time collection of current and other parameters of each branch, helping factories optimize energy allocation and improve energy utilization efficiency.

  • rail transitThe rail transit system is highly dependent on electricity, and AMC16Z-FD can be used to monitor the current of the air conditioning distribution circuit inside the rail transit train carriage. For example, installing this device on the top of each carriage can monitor the remaining current of the 4-channel air conditioning incoming distribution circuit and the 8-channel air conditioning load current. By monitoring these electrical parameters in real time, the operating status of the air conditioning can be determined, potential faults can be detected, and the normal operation of the air conditioning system can be ensured, providing passengers with a comfortable riding environment.

  • communication base stationThe equipment of communication base stations has a strong dependence on power, and using AMC16Z-FD can improve the safety of the equipment and reduce the risk of downtime caused by power problems. This device can monitor the current and other parameters of the DC power supply system of communication base stations in real time, detect power abnormalities in a timely manner, and ensure the stable operation of base station equipment.

  • Large scale industrial productionIn some large industrial sites, the safety of electrical equipment directly affects the production process. AMC16Z-FD can monitor the DC power supply system in industrial production, real-time grasp the current situation of each branch, provide guarantees for the stable operation of industrial production, and help improve overall production efficiency.

DC voltage monitoring device with multiple output circuit monitoring 485 communicationProduct selection:

直流电压监测装置 多出线回路监测 485通讯


DC voltage monitoring device with multiple output circuit monitoring 485 communicationTechnical Specifications

直流电压监测装置 多出线回路监测 485通讯

Overall dimensions:

直流电压监测装置 多出线回路监测 485通讯

One of the application scenarios

直流电压监测装置 多出线回路监测 485通讯





Application Scenario 2

直流电压监测装置 多出线回路监测 485通讯


直流电压监测装置 多出线回路监测 485通讯


Application Case of AMC16Z-FD DC Current Monitoring Device

  • data centerThe AMC16Z series DC precision distribution monitoring device can provide real-time monitoring of the full electrical parameters, input and output switches, and lightning protection status of the A+B incoming lines and 192 outgoing lines in the data center. The device is designed to be compact and highly integrated with the monitoring circuit. The alarm thresholds for all measurement channels can be set separately, and any out of limit event will immediately trigger the system's sound and light alarms. It can also be paired with an insulation detection module to detect the insulation status of the DC system bus and branch, helping data centers achieve efficient and safe power management.

  • rail transitOn subway trains, an AMC16Z-FAL module (similar in function to AMC16Z-FD) is installed on the top of each carriage, which can monitor the residual current of 4 air conditioning inlet distribution circuits and 8 air conditioning load currents. The data is transmitted to the data acquisition terminal at the front of the train through 485 communication. After the train arrives at the station, the data is summarized on the comprehensive monitoring platform. By monitoring these electrical parameters in real-time, the operating status of the air conditioning system can be determined, potential faults can be detected, and the normal operation of the air conditioning system can be ensured, providing passengers with a comfortable riding environment.

  • communication base stationCommunication base station equipment has a strong dependence on electricity. The AMC16Z-FJY intelligent DC distribution cabinet monitoring device (in the same series as AMC16Z-FD) can be used to monitor the insulation status of the DC power supply of communication base stations, improve equipment safety, and reduce the risk of downtime caused by power problems. The AMC16Z-FD DC current monitoring device can also be applied to communication base stations to monitor the current and other parameters of the DC power supply system in real time, ensuring the stable operation of base station equipment.