Welcome Customer !

Membership

Help

Dexon Instruments (Huai'an) Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Dexon Instruments (Huai'an) Co., Ltd

  • E-mail

    25291658@qq.com

  • Phone

    13951262528

  • Address

    No. 258-8 Huancheng West Road, Jinhu County Economic Development Zone, Huai'an City, Jiangsu Province

Contact Now

DKS-UHZ Basic Series Magnetic Flip Plate Liquid Level Gauge

NegotiableUpdate on 09/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The on-site display magnetic flap level gauge has the advantages of intuitive and eye-catching display, no need for power supply, easy and reliable installation, low maintenance, and low maintenance costs. It is a replacement product for glass tube and glass plate level gauges. It can be widely used for liquid level detection of tanks, tanks, and containers in industries such as petroleum, chemical, power station, pharmaceutical, metallurgical, shipbuilding, and water/sewage treatment.

Product Details

  • DKS-UHZBasic seriesMagnetic flap level gaugeIt is a multifunctional integrated instrument. It transmits the liquid level changes to the on-site indicator to indicate the actual height of the liquid level. And equipped with liquid level alarm and liquid level remote transmission device. The liquid level alarm can achieve upper and lower limit control of liquid level, limit alarm, and accident interlocking. The liquid level remote transmission device can linearly convert liquid level changes into direct current420mADCThe current signal enables remote liquid level indication, detection, control, and recording. The liquid level gauge has explosion-proof and intrinsic safety protection performance. The whole machine is made of corrosion-resistant materials. So it has corrosion resistance and explosion-proof functions.

    Features:
    Simple structure and easy installation Complete detection functions Large measurement range Indicating novel and intuitive readings Corrosion resistant and explosion-proof

    Structural principle:
    The liquid level gauge consists of three parts: basic type, on-site indication, liquid level alarm, and liquid level remote transmission device. The basic type is developed based on Archimedes' theorem that magnetic floats generate buoyancy in liquids and the properties of magnetic steel that repel each other in the same direction and attract each other in the opposite direction. According to the above principle, the linear change in liquid level is transmitted to the on-site indicator through magnetism, with the liquid level being red and the gas phase being white. The liquid level alarm uses magnetic float material and a contactless alarm switch to activate the converter relay contacts according to the given liquid level value, thereby achieving the purpose of liquid level control. The alarm switch is installed at the required control position of the liquid level, and the converter is installed in the control room. The liquid level remote transmission device uses magnetic materials to linearly convert the changes in liquid level into direct current420MAThe current signal is transmitted to the secondary instrument for remote transmission, measurement, control, and recording of liquid level.


  • Basic type

    measurement range

    H500 800 1100 1400 1700 2000 2500 3000 4000 5000 6000......10000 
              010000MMUsers can freely choose from within

    Indication accuracy

    +-5mm

    Medium density

    0.45g/cm3

    Poor medium density and quality

    0.15g/cm3

    Operating Temperature

    196~120Celsius degree120~300Celsius(high-temperature type)

    medium viscosity

    1ST(10-4square meter/S

    flange connection

    1PN254.0MPWhen, the flange isJB/T82.2~94DN25PN4.0Movable convex flange.
    2PN6.310.016.0MPaThe flange isT82.2~94DN25Fixed flange.
    3PVCMaterial flangeJB/T82.1~94PN1.0MPa,DN20.
    Other flange standards(asHGJGBANSIWaiting for standards)Please specify between the design department and the user.

    liquid level alarm

    output format

    CONTACT CAPACITY

    working life

    Alarm accuracy

    power supply

    ambient temperature

    Three normally open and three normally closed switch signals

    220VAC 2A

    >10The fifth power of

    +-5mm

    24VDC 220VAC 50HZ

    -40~60Celsius

    Liquid level remote transmission device

    Remote transmission range

    0~10000mm(Choose arbitrarily)

    Long distance transmission

    3Km

    precision

    +-10.0mm

    load resistor

    250An(Excluding wire resistance200An)

    backlash

    +-10.0mm

    power supply

    24V.DC220V.AC50HZ

    output signal

    4~20mADC

    ambient temperature

    -40~60Celsius

    BOutlet connector

    internal threadM201.5