Welcome Customer !

Membership

Help

Shanghai Keyang Technology Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Shanghai Keyang Technology Co., Ltd

  • E-mail

    zhangbd@keyontechs.com

  • Phone

    18317143469

  • Address

    No. 7 Xinghao Road, Fengjing Industrial Park, Jinshan District, Shanghai

Contact Now

F series electromagnetic flowmeter

NegotiableUpdate on 01/05
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The F series electromagnetic flowmeter can measure the volumetric flow rate of general conductive liquids, strong corrosive liquids such as strong acids and alkalis, and uniform liquid-solid two-phase suspensions such as mud and slurry.
Product Details

F series electromagnetic flowmeter

The F series electromagnetic flowmeter consists of a sensor and a converter. It operates based on Faraday's law of electromagnetic induction and is used to measure the volumetric flow rate of conductive liquids with a conductivity greater than 5 μ S/cm. In addition to measuring the volumetric flow rate of general conductive liquids, it can also be used to measure the volumetric flow rate of strongly corrosive liquids such as strong acids and alkalis, as well as homogeneous liquid-solid two-phase suspensions such as mud and slurry. It is widely used in flow calculation in industrial sectors such as petroleum, chemical, metallurgical, textile, papermaking, environmental protection, food, municipal management, water conservancy construction, river dredging, and other fields.


Product performance:

Stable and reliable traffic

high precision

No pressure loss

Strong vibration resistance

Easy installation and debugging


F series electromagnetic flowmeterProduct Parameters:

Nominal meridian: DN15~DN1200

Electrode materials: 316L, Hb, Hc, Ti, Ta, Pt

Lining materials: chloroprene rubber, polyurethane PTFE、PFA、F46

Dielectric conductivity: ≥ 5 μ s/cm, softened water is 20 μ s/cm

Accuracy level: ± 0.5% RS~± 1.0% RS

Flow velocity range: 0.3m/s~12m/s

Environmental temperature: -20 ℃~+60 ℃

Medium temperature: A: ≤ 80 ℃; B≤120℃; C ≤ 180 ℃ (split PTFE lining)

Nominal pressure: 0.6MPa~4.0MPa (customized according to caliber or special requirements)

Protection level: IP65, IP67, IP68 (split)

Output signal: 4~20mA, frequency/pulse, alarm output

Communication output: RS485, RS232, MODBUS485, HART, PROFIBUS DP

Power supply voltage: 220AC, 24VDC

Installation form: integrated or split

Flange standards: National Standard, American Standard, Japanese Standard, German Standard

Shell and flange materials: standard stainless steel, carbon steel, etc