E-mail
zhangbd@keyontechs.com
-
Phone
18317143469
-
Address
No. 7 Xinghao Road, Fengjing Industrial Park, Jinshan District, Shanghai
Shanghai Keyang Technology Co., Ltd
zhangbd@keyontechs.com
18317143469
No. 7 Xinghao Road, Fengjing Industrial Park, Jinshan District, Shanghai
KMS traffic metering boxIt is an on-site display and accumulation unit for flow measurement, which can be combined with various flow transmitters and sensors to form a high-precision flow measurement system.
Product performance:
Suitable for measuring steam, gas, natural gas, and liquids
Automatically perform density compensation, Reynolds number compensation, and coefficient of expansion compensation
Equipped with functions such as small traffic billing, stop gas judgment, over plan consumption billing, power outage recording, and paperless recording, meeting the needs of trade settlement measurement
Can automatically save 65536 sets of the latest historical data, and automatically draw historical curves such as flow rate, temperature, pressure, etc
Intelligent fault-tolerant function - when temperature and pressure compensation measurement signals are abnormal, the corresponding manual set values are automatically used for compensation calculation
There are no adjustable devices such as potentiometers or coded switches inside the instrument, thereby improving its vibration resistance, stability, and reliability
Specially designed WDT circuit, power on reset circuit, and power-off data protection circuit ensure that the instrument operates normally when powered on and that power-off data is not lost. Power outage data protection does not require backup batteries, with a protection time of 10 years
High definition Chinese and character display of all key parameters, with screen saver function to extend screen lifespan
Set the data recall function to record all modifications made to the set data after factory settings, and display them on the query screen
Backup power function, automatic system switching, instrument can work normally for 72 hours after power failure
KMS flowmeterProduct parameters for measuring boxes:
Measure the flow input signal
Analog flow signal (AI1): 4~20mA DC
Frequency flow signal (f) frequency: 1~10000 Hz
Measurement of pressure input signal (AI2): 4~20mA DC
Measure temperature input signal
Thermistor Pt 100 division, thermocouple K, E division, etc
Current: 4~20mA DC
basic error
Frequency signal input: ± 0.1% of the reading value
Temperature signal input: ± 0.3 ℃ (when t ≤ 300 ℃)
± 0.1% of the reading value (when t>300 ℃)
Current and voltage input: ± 0.1% of full range
Current output: ± 0.1% of full scale
Compensated flow display: ± 0.1% of full range
communication
Communication interface: RS-485 or RS-232 serial interface (optoelectronic isolation)
Communication speed: 9600, 4800, 2400, or 1200 baud rate
Transmission media: GPRS, RS485, fiber optic, etc
Display capability
Display with 3.5 "320 × 240 graphic dot matrix high-definition, 65K true color TFT
Display all key parameters in Chinese and characters on a single screen
Accumulated flow and heat display: up to 8 digits
Display of parameters such as instantaneous flow rate, instantaneous heat, fluid temperature, fluid pressure, etc.: up to 6 digits
Display temperature with one decimal place. When displaying instantaneous flow and pressure, the decimal place is determined by the set data