Fixed radiation dose alarm device

NegotiableUpdate on 01/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Fixed radiation dose alarm is a new type of continuous monitoring and alarm device for x - γ radiation. It adopts a specially designed preamplifier circuit, which has the characteristics of high sensitivity, easy operation, automatic display, and over threshold alarm. It can provide real-time x - γ radiation dose rate.
Product Details

Fixed radiation dose alarm is a new type of continuous monitoring and alarm device for x - γ radiation. It adopts a specially designed preamplifier circuit, which has the characteristics of high sensitivity, easy operation, automatic display, and over threshold alarm. It can provide real-time x - γ radiation dose rate.


FN-PMT5 plastic scintillator detector

Detector

3 * 2-inch plastic scintillator+PMT;

measurement range

10nGy/h-1mGy/h; (Optional 1nSv/h-5Sv/h)

response time

50ms

Update rate

1 time/second (average value within 1 second)

measurement error

≤±15%

Energy response

30Kev~7Mev

Usage environment

Temperature -10 ℃~+50 ℃, relative humidity (at 40 ℃) ≤ 98%

size

Host: 260 × 160 × 68mm (excluding base); Probe: φ 60 × 320 mm.

FN-GM10 GM detector

detector

Metal GM tube detector (energy compensation).

measurement range

0.01μSv/h~2500μSv/h。 (Optional higher range)

Sensitivity

1μSv/h>5CPS。

response time

1S (processed by algorithm).

measurement error

≤± 15%.

Energy response

48Kev~3Mev ≤±30%。

power supply

Municipal power 220V

Usage environment

Temperature -10 ℃~+50 ℃, relative humidity (at 40 ℃) ≤ 98%.

size

Host: 260 × 160 × 68mm (excluding base); Probe: 50 × 212 mm.

FN-6LiF type neutron detector

detector

6LiF scintillation neutron detector

measurement range

0.1μSv/h~100mSv/h

Energy response

0.025ev~14Mev

Count lifespan

infinite

sensitivity

0.7CPS/μSv/h

measurement error

≤± 15%.

Usage environment

Temperature -15 ℃~+60 ℃, relative humidity (at 40 ℃) ≤ 98%

size

Host: 260 × 160 × 68mm (excluding base); Probe: 120mm x 320mm

FN-3He type neutron detector

detector

3He proportional counter

measurement range

0.1μSv/h~100mSv/h

Energy response

0.025ev~16Mev

sensitivity

Approximately 1.4 CPS/μ Sv/h

Usage environment

Temperature -20 ℃~+50 ℃, relative humidity (at 40 ℃) ≤ 98%

measurement error

≤± 15%.

size

Host: 260 × 160 × 68mm (excluding base);

Spherical probe: φ 300mm × 250x242mm;

Cylindrical probe: φ 200 × 250mm.


638115530518502389350.png