Product Introduction:
Adopting fully automatic voltage rise (fall), the leakage current of each test sample is automatically read out, and the entire process is fully automated. The test data is automatically printed, effectively solving the irregular testing methods in the past, simplifying the testing procedures, and improving the testing speed. More reliable identification of leakage current, power frequency withstand voltage and other parameters of insulated boots (gloves). It ensures the safety of experimental workers and is an ideal insulated boot (glove) equipment.
Features:
1The instrument can be used simultaneously8Test with only insulated boots or gloves and measure the leakage current of each sample.
2The insulation shoe test adopts a dry test method with small steel balls placed inside, which breaks away from the traditional practice of pouring water into the shoe for testing and making it difficult to dry after the test is completed.
3The measurement of voltage and current adopts real-time comparison of high and low voltage corresponding to each other to ensure the accuracy of the measured voltage and current values.
4The high and low voltage are separated, and the leakage current is transmitted back to the control box using anti-interference wireless transmission technology, greatly protecting personal safety.
5Each test sample has a breaking mechanism. When any one of the circuits breaks down or exceeds the set leakage current value, the test sample will automatically detach from the test without affecting the testing of other samples.
6The instrument adopts a large screen LCD Chinese character display, which displays a large amount of information. One screen simultaneously displays the test voltage8High voltage leakage current, perpetual calendar, timing time and other parameters, as well as Chinese character prompts.
7Using a high-precision stepper motor to control the voltage regulator's boosting process, the voltage withstand test is fully automated. After the start of the experiment, the instrument automatically closes and boosts the voltage at the required speed according to the national standard. When the predetermined voltage is reached, the timer starts and the test voltage is maintained. When the timer reaches, the voltage automatically drops, and when it reaches zero, the power is automatically turned off, indicating the end of the experiment. At the same time, the leakage current of each test sample is displayed, and the test results are automatically saved.
8 The insulation boot test has a metal grounding tray, and the insulation glove test has a container for easy operation.
9The transformation ratio of the test transformer can be freely set and can be matched with the customer's existing transformer.
10It has overcurrent protection function.
11The test data can be compared withPCMachine connected, directly output test report, report format can be set according to customer requirements.
Technical Specifications:
1. Input voltage:AC220V/50Hz
2. Capacity:3kVA
3. High voltage:0~30kV
4. High voltage current:0~100mA
5. Test quantity: Each time6only
6Measurement data: can display and print the voltage value of each test sample; Leakage current value
7Overcurrent protection; Overvoltage protection; Customize time, voltage, and leakage current values
8LCD display, fully Chinese menu operation, with printing
9Measurement accuracy: Voltage±2%(±3One word) current±2%(±3One word)
Maintenance and upkeep:
1After using the device, the water in the sink should be drained completely.
2If not used for a long time, the inside and outside of the sink should be kept dry, and the electrode rod and insulation rod should be free of moisture.
3Before use, the insulation resistance of the insulation rod should be measured, and if necessary, the withstand voltage value should not be lower than when tested with high voltage20KV.