HRM metal float flowmeter(Also known as metal rotor flowmeter)It is a variable area flow meter based on float position measurement. The nitrogen flow meter adopts a fully metallic structure and modular concept design, due to its small volumeSimple structure, reliable operation, high accuracy, and easy maintenance,Therefore, nitrogen flow meters are widely used in various industries for flow measurement and process control of small flow rates, low flow rates, and various harsh medium conditions in complex and harsh environments.
There are multiple measurement forms available for users to choose from based on different occasions and user needs; According to the output form, there are local indication type, remote transmission output type, and control alarm type; According to explosion-proof requirements, there are three types: ordinary type, intrinsic safety type, and isolated explosion-proof type;There are also varieties such as corrosion-resistant, jacket type, damping type, etc. Widely used in the measurement and automatic control of liquid and gas flow in departments such as national defense, chemical industry, petroleum, metallurgy, power, environmental protection, medicine, and light industry.
2、 Structure and working principle
Composed of two parts:
²Sensors - measuring tubes and floats;
²Signal transmitter - indicator;
HRM metal float flowmeterThere are four types of liquid contact materials for sensors: stainless steel, Hastelloy, titanium, and stainless steel lined with PTFE; Users can choose different contact materials based on different process pressures and corrosive requirements of the medium to meet the pressure resistance and anti-corrosion needs of the process.
The measurement of flow is completed by the transmitter inside the indicator, which couples the magnetic steel to sense the change in float position to indicate the flow and transmit the signal remotely. When the measured medium flows through the measuring tube from bottom to top, the float is balanced by the vertical upward pushing force of gravity, buoyancy, and fluid flow velocity. The float is relatively stationary at a certain position, which varies with the ring area of the float and the cone tube, as well as the fluid flow velocity. The position of the float corresponds to the flow rate of the measured medium.
3、 Technical parameters
The main technical parameters are as follows:
1. measurement range: Water(20℃)(2.5~150000)L/h;
Air (0.1013 MPa, 20 ℃) (0.07-2000) m3/h。
2. accuracy classLevel 1.5(Special Type 1.0).
3. turndown ratio: 10:1(Special type 20:1).
4. work pressure: DN15~50,4.0 MPa(Special type 25MPa);
DN80~150,1.6MPa(Special type 16MPa).
Clamp type pressure rating: 1.6MPa
5. medium temperature-80 ℃~220 ℃ (F46 flowmeter with lining 0 ℃~85 ℃), high temperature type 300 ℃.
6. Environmental temperature: -40 ℃ to+120 ℃ (electric remote transmission type ≤ 65 ℃)
7. Medium viscosity: DN15<5mPa · s; DN25~150<250mPa·s。
8. LCD display instantaneous flow display numerical range: 0-50000
Accumulated traffic display value range: 0~99999999
9. Output standard signal: two-wire 4-20mA/HART protocol.
Alarm signal: open collector, MAX100Ma@30VDC Internal impedance 100W
10. Power supply standard type: 24VDC (10.8VDC~36VDC)
Communication type: 220VAC (85-265VAC)
Battery type: 3.6@4AH Nickel-metal hydride battery
11. Electrical interface M20 × 1.5 PG11、1/2”NPT
12. connection methodFlange connection, threaded connection, etc;
The flange adopts GB/T9119.8-10 standard, or according to customer requirements.
13. total length:Standard type: 250mm (except for other installation methods).
14. Measurement tube material: ordinary 304SS, corrosion-resistant 304SS lined with PTFE, 316L, 316L lined with PTFE, etc.
15. Explosion-proof ratingEX intrinsic safety explosion-proof mark Exib Ⅱ CT3-6; Ed explosion-proof mark Exd Ⅱ BT3-6 (round head).
4 flow range
The flow range of nitrogen flowmeter is shown in Table 1
Table 1
|
Corrosion resistant diameter DN(mm) |
Ordinary diameter DN(mm) |
Flow range |
The biggest pressure loss |
||
|
Air m3/h 20℃ 0.101325 MPa |
Water L/h at 20 ℃ |
Air (kPa) |
Water (kPa) |
||
15 |
15 |
0.07~0.7 |
2.5~25 |
7.1 |
6.5 |
0.11~1.1 |
4.0~40 |
7.2 |
6.5 |
||
0.18~1.8 |
6.0~60 |
7.3 |
6.6 |
||
0.28~2.8 |
10~100 |
7.5 |
6.6 |
||
0.40~4.0 |
16~160 |
8.0 |
6.8 |
||
0.70~7.0 |
25~250 |
10.8 |
7.2 |
||
1.00~10 |
40~400 |
10 |
8.6 |
||
25 |
1.60~16 |
60~600 |
14 |
11.1 |
|
25 |
3.00~30 |
100~1000 |
7.7 |
7 |
|
4.50~45 |
160~1600 |
8.8 |
8 |
||
7.00~70 |
250~2500 |
12 |
10.8 |
||
50 |
11~110 |
400~4000 |
19 |
15.8 |
|
50 |
18~180 |
600~6000 |
8.6 |
8.1 |
|
25~250 |
1000~10000 |
10.4 |
11 |
||
80 |
40~400 |
1600~16000 |
15.6 |
17 |
|
80 |
75~750 |
2500~25000 |
8.1 |
||
100 |
100~1000 |
4000~40000 |
9.5 |
||
100 |
150~1500 |
6000~60000 |
10 |
||
150 |
125 |
8000~80000 |
|||
10000~100000 |
|||||
150 |