Handheld ultrasonic flowmeterUFM-H
Accuracy ± 1% (achieve this accuracy first)
Display instantaneous flow rate, flow velocity, cumulative flow rate, signal status, etc. on the same screen with 4 lines of Chinese characters
Built in data logger that can record dates, cumulative traffic, signal status, working time, etc
OCT outputs positive and negative, net cumulative pulse signal and frequency signal
RS232 interface is used for network detection or exporting recorded data
Suitable for fluid measurement in pipelines of various sizes
Flow velocity measurement range (0.01 to ± 32m/s)
Suitable for measuring uniform, single, and stable liquids such as water, seawater, sewage, alcohol, various oils, etc
Suitable for steel, stainless steel, cast iron PVC、 Uniform and dense pipelines such as fiberglass reinforced plastic
The straight pipe section should meet the requirements of upstream 10D, downstream 5D, and 30D from the pump outlet
Built in nickel hydrogen rechargeable battery can work continuously for more than 10 hours
Small size (200 * 92 * 32mm), light weight (538 grams)
Handheld ultrasonic flowmeterUFM-H
·Measurement host
Accuracy: 1.0%
Repeatability: 0.2%
Maximum flow velocity: 32m/s
Measurement cycle: 500ms (2 times per second)
Measurement principle: Ultrasonic time difference principle, dual CPU parallel operation, 4-byte floating-point operation
Flow direction: forward and reverse flow are measured separately, and net flow can be measured
Display: 2 * 10 backlit Chinese character LCD display
Operation: 4 * 4 touch keyboard
Input: 5 channels of 4-20mA input with an accuracy of 0.1%, capable of inputting signals such as pressure, liquid level, temperature, etc
Output: Current signal: 4-20mA or 0-20mA, impedance 0-1k Ω, floating, accuracy 0.1%
Frequency signal: optional between 1 and 9999Hz (OCT output)
Pulse signal: positive, negative, net flow and heat accumulation pulses, relay and OCT output
Alarm signal: Relay and OCT output, with nearly 20 selectable source signals
Data interface: RS232 serial interface, optional RS485 or CAN bus mode
Other functions: Memory of daily, monthly, and yearly accumulated traffic, power on and off times, traffic and traffic management functions
Optional automatic or manual accumulation function, memory of daily work status
Programmable quantitative (batch) controller
Fault self diagnosis function
Network working methods, etc
Working power supply: AC220V, DC8-36V or AC7-30V
According to the site, our company's UPS-72 backup charging power supply can be selected,
When the power is cut off (AC220V), the flow meter works continuously for 72 hours and automatically charges after being powered on again
Power consumption: less than 2W
Working hours: continuous
Environmental temperature: -30 ℃~80 ℃ (please contact the manufacturer for requirements above this temperature range)
Environmental humidity: 85% RH without condensation
Protection level: IP65
Explosion proof grade: EXd Ⅱ BT4 (F2 type)
质 量: F1:2.5kg; F2:2.7kg; FN:2.5kg FS:1.5kg
Dimensions: F1/FN: 251 * 192 * 80mm; F2: 290 * 270 * 110mm; FS: 80 * 250 * 160mm;
·Sensors
External application type: Standard S1 type, suitable for pipe diameters ranging from DN15 to DN100mm
Standard M1 type, suitable for pipe diameters ranging from DN50 to DN700mm
If the pipeline conditions are good, larger diameters can also be measured
Standard L1 type, suitable for pipe diameters ranging from DN300 to DN6000mm
Insertion type: The material of the pipeline is not limited (for non-stop installation) and is suitable for pipes with a diameter of DN80 or above
Pipe section type: π - shaped pipe section type: suitable for pipe diameters of DN10-DN40, with a measurement accuracy of ± 0.5% for the entire machine
Standard pipe section type: suitable for pipe diameters of DN50-DN1000, with a measurement accuracy of ± 0.5% for the entire machine
Applicable temperature: External application type:<110 ℃ Other: -40 ℃~+160 ℃
Protection level: IP68 (can work in water immersion, water depth ≤ 3 meters)
·Fluid
Types: Uniform liquids that can transmit ultrasonic waves, such as water, food oil, gasoline, coal diesel, crude oil, alcohol, etc
Turbidity: ≤ 10000ppm, with low bubble content.
Humidity: -40 ℃~160 ℃ (recommended for long-term measurement with external sensors below 80 ℃)
·Pipeline
Pipe materials: steel, cast iron PVC、 All materials such as fiberglass, cement pipes, etc. are dense and allowed to have lining
Lining materials: epoxy asphalt, rubber, mortar, polypropylene, polystyrene, rubberwood, polytetrafluoroethylene, etc
Inner lining: 15mm~6000mm
Length of straight pipe section: upstream ≥ 10D, downstream ≥ 5D, distance from pump outlet ≥ 30D (D refers to pipe diameter)
【 Selection Tips 】
The following parameters need to be determined in detail when selecting: pipeline diameter, pipeline material, measuring medium, and process
Temperature, working pressure, installation method (external binding, insertion, pipeline), power supply (24V or 220V),
Output mode (4-20mA, pulse output or 485 communication), maximum flow rate (working state or standard state), whether required or not
explosion-proof