1) The flow temperature method heat metering system is a household metering system that uses flow coefficient and temperature coefficient as the basis for user thermal energy allocation
2) The implementation process is to transform the existing vertical single tube sequential heating system into an adjustable single tube crossover system with a temperature collector installed at the inlet of the three-way balance regulating valve. Install three-way balance regulating valves and temperature collectors on each radiator branch pipe to measure the water supply temperature of the riser. Install one three-way balance regulating valve and one temperature collector on each non bottom radiator to measure the supply water temperature of the riser. The supply water temperature measured on the next floor is the return water temperature of the previous floor. Install one three-way balance regulating valve and one temperature collector on each supply pipe and one temperature collector on each return pipe for the bottom radiator. Install floor relays on each floor, which collect temperature data from temperature collectors wirelessly. Install collection calculators in each building to collect data from the building's general table and floor relays, perform heat allocation measurement for residents in the community, and upload the data to the monitoring center
The flow temperature method introduces temperature and flow rate into heat distribution measurement technology, using the temperature difference of the heat medium and the flow rate of the fixed flow rate of the heating system in the building to introduce them into the heat distribution measurement technology. The concept of relatively stable proportion between the temperature difference of the heat medium and the fixed flow rate of the heating system in the building is used to allocate heat energy based on the temperature difference and flow rate ratio of each calculation unit, and the total heat energy is calculated and distributed by household. The system obtains the flow ratio of each household/riser through a temperature collector, and the collection calculator calculates the thermal energy sharing coefficient of each household based on their inlet and outlet water temperature data and corresponding flow ratio data. Then, based on the measured thermal energy value in the main table, the actual thermal energy consumption of each household is finally calculated.