E-mail
1095143601@qq.com
-
Phone
18936740760
-
Address
No. 358 Shenhua Avenue, Jinhu County Industrial Park
Jiangsu Hengke Measurement and Control Instrument Co., Ltd
1095143601@qq.com
18936740760
No. 358 Shenhua Avenue, Jinhu County Industrial Park
The EJA510E/530E pressure and pressure transmitter is suitable for measuring the pressure of liquids, gases, or vapors and converting it into a 4-20mA DC current signal output. It has functions such as fast response, remote setting, and self diagnosis.
The EJA-E series supports BRAN, HART/HART (1-5V) low power consumption, and FOUNDATION ™ Fieldbus or PROFIBUS PA communication protocol.
Specifications
| EJA510E/EJA530E pressure and pressure transmitters | |||||
| A membrane box | B membrane box | C membrane box | D membrane box | ||
| measurement range | 100~200kPa | -0.1~2MPa | -0.1~10MPa | -0.1~50MPa | |
| (-14.5~29psi) | (-14.5~290psi) | (-14.5~1450psi) | (-14.5~7200psi) | ||
| Measurement range | 10~200kPa | 0.1~2MPa | 0.5~10MPa | 5~50MPa | |
| (1.45~29psi) | (14.5~290psi) | (72.5~1450psi) | (720~7200psi) | ||
| precision | ±0.055% | ±0.055% | ±0.055% | ±0.055% | |
| Protection level | IP66/IP67,NEMA 4X | ||||
| Explosion proof specifications | NEPSI , FM,CENELEC ATEX,CSA,IECEx | ||||
| output signal | 4-20mA DC, BRAIN, HART/HART (1-5V DC) low power consumption, FOUNDATION ™ Fieldbus or PROFIBUS PA two-wire digital communication | ||||
| power supply | BRAN and HART: 10.5~42V DC (regular and explosion-proof) 10.5~32V DC (with lightning arrester) 10.5~30V DC (intrinsic safety, n-type, non flammable) Digital communication (BRAN and HART: small 16.6V DC) HART (1-5V): 9~28V DC | ||||
| Fieldbus: 9~32V DC (Intrinsic Safety Entity Mode: 9~24V DC, Intrinsic Safety FISCO Mode: 9~17.5V DC) | |||||
| ambient temperature | -40~85℃ (-40~185℉) (普通型) | ||||
| -30~80 ℃ (-22~176 ℉) (internal display table) | |||||
| process temperature | -40~120℃ (-40~248℉) (普通型) | ||||
| High overvoltage | 4MPa | 4MPa | 20MPa | 60MPa | |
| (580psi) | (580psi) | (8700psi) | (8700psi) | ||
| install | Direct installation/2-inch pipe installation | ||||
| Material of liquid receiving components | bellows | Hastelloy C-276 | |||
| Process connector | SUS316L, 哈氏合金C-276 | ||||
| shell |
Cast aluminum alloy, corrosion-resistant cast aluminum alloy, ASTM CF-8M stainless steel |
||||