E-mail
1085201916@qq.com
-
Phone
18455083610
-
Address
Chang'an Middle Road, Anle Community, Tongcheng Town, Tianchang City, Anhui Province
Anhui Kangtai Electric Co., Ltd
1085201916@qq.com
18455083610
Chang'an Middle Road, Anle Community, Tongcheng Town, Tianchang City, Anhui Province
1Industrial multi-point thermocoupleapplication
Multi point thermocouples are suitable for production sites where temperature gradients are not significant and multiple positions or locations need to be measured simultaneously. Widely used in large fertilizer synthesis towers, storage tanks, and other devices.
2. Main technical parameters of multi-point thermocouple
Electrical export: M27X2, NPT3/4
Hot sound time: ≤ 8S
Wire diameter: Φ 3
Protection level: IP65
3Industrial multi-point thermocoupleModel and Specifications
| Model number | Dividing number | Temperature measurement range ℃ | Temperature measurement points | Protective tube material |
| WRN-230D | K | 0-1000 | 2-12 | GH3030 |
| 0-800 | 1Ci18Ni9Ni | |||
| WRE-230D | E | 0-600 | 1Ci18Ni9Ni | |
| WRN-430D | K | 0-1000 | GH3030 | |
| 0-800 | 1Ci18Ni9Ni | |||
| WRE-430D | E | 0-600 | Ci18Ni9Ni |
1. Order thermocouple level I according to the agreement;
2. Order the remaining materials of the protective tube according to the agreement;
3. External protection tube users should bring their own
4. Installation fixed form
Fixed thread
| Temperature measurement points | M | D | H | h | SW | d |
| 2—6 | M27x2 | ¢40 | 28 | 5 | 32 | ¢20 |
| 7—12 | M33x2 | ¢48 | 33 | 5 | 36 | ¢34 |
Fixed flange
| Temperature measurement points | D | D1 | D2 | H | do | d |
| 2—6 | ¢105 | ¢75 | — | 5 | 32 | ¢20 |
| 7—12 | ¢115 | ¢85 | — | 5 | 36 | ¢34 |
5. Selection Notice
Model 1
2 division marks
3 Accuracy Levels
4 thermocouple points
5 Installation and fixing forms
6. Material of protective tube
7 Length or Insertion Depth
Example: Multi point thermocouple, K-type, 3 points. L grade, fixed thread M27X2, L1=1200, L2=1500, L3=2000, WRN-220D3I grade L1=1200, L2=1500, L3=2000, thread M27x2