Industrial multi-point thermocouple

NegotiableUpdate on 01/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Industrial multi-point thermocouples are suitable for production sites where temperature gradients are not significant and multiple positions or locations need to be measured simultaneously. Widely used in large fertilizer synthesis towers, storage tanks, and other devices.
Product Details

1Industrial multi-point thermocoupleapplication

Multi point thermocouples are suitable for production sites where temperature gradients are not significant and multiple positions or locations need to be measured simultaneously. Widely used in large fertilizer synthesis towers, storage tanks, and other devices.

2. Main technical parameters of multi-point thermocouple

Electrical export: M27X2, NPT3/4

Hot sound time: ≤ 8S

Wire diameter: Φ 3

Protection level: IP65

3Industrial multi-point thermocoupleModel and Specifications

Model number Dividing number Temperature measurement range ℃ Temperature measurement points Protective tube material
WRN-230D K 0-1000 2-12 GH3030
0-800 1Ci18Ni9Ni
WRE-230D E 0-600 1Ci18Ni9Ni
WRN-430D K 0-1000 GH3030
0-800 1Ci18Ni9Ni
WRE-430D E 0-600 Ci18Ni9Ni

1. Order thermocouple level I according to the agreement;

2. Order the remaining materials of the protective tube according to the agreement;

3. External protection tube users should bring their own

4. Installation fixed form

Fixed thread

Temperature measurement points M D H h SW d
2—6 M27x2 ¢40 28 5 32 ¢20
7—12 M33x2 ¢48 33 5 36 ¢34

Fixed flange

Temperature measurement points D D1 D2 H do d
2—6 ¢105 ¢75 5 32 ¢20
7—12 ¢115 ¢85 5 36 ¢34

5. Selection Notice

Model 1

2 division marks

3 Accuracy Levels

4 thermocouple points

5 Installation and fixing forms

6. Material of protective tube

7 Length or Insertion Depth

Example: Multi point thermocouple, K-type, 3 points. L grade, fixed thread M27X2, L1=1200, L2=1500, L3=2000, WRN-220D3I grade L1=1200, L2=1500, L3=2000, thread M27x2