putting-into-type liquid level meterIt is based on the principle that the measured liquid static pressure is proportional to the height of the liquid, using the piezoresistive effect of diffused silicon or ceramic sensitive elements to convert static pressure into electrical signals. After temperature compensation and linear correction, it is converted into a 4-20mADC standard current signal output. The sensor part of the SC-500 series static pressure input level gauge can be directly inserted into the liquid, and the transmitter part can be fixed with flanges or brackets, making installation and use extremely convenient.
Measurement range of the input static pressure level gauge: 0.3-100m (optional by the user) Accuracy: 0.2, 0.5, 1.0 levels Working temperature: -20~80 ℃ Output signal: 2-wire 4-20mADC Power supply voltage: standard 24VDC (12-36VDC) Non sensitive area: ≤± 1.0% FS Load capacity: 0-600 Ω Relative temperature of input type liquid level gauge: ≤ 85% Protection level: IP68 Explosion proof mark: Exia Ⅱ CT4-6
Characteristics of Input Liquid Level Gauge
Good stability and high accuracy
Selection of Input Liquid Level Gauge
Type spectrum Remarks
Input type static pressure level gauge Class quality
1
Cable type
2
Rod type (sensor installed at the bottom, directly in contact with liquid medium)
3
Anti-corrosion type
4
Pressure rod type (sensor installed on the upper part, not in direct contact with the medium) Process connection form T
Bracket installation N
Flange installation DN40 PN1.0 Y
Special Agreement Sensor connection material
1
304
Rod style
2
316
3
316L
4
Nitrile rubber and polyvinyl chloride composite Cable type
5
Polytetrafluoroethylene (polypropylene flange) Explosion proof method O
Not explosion-proof E
Intrinsic safety explosion-proof Exia Ⅱ CT6 Display mode O
Without on-site instructions Z
Equipped with ammeter indication (0-100% scale) X
Equipped with LCD digital display Weight distribution situation O
No need for counterweight W
Need to balance weight
-□
Installation height (mm)
-□
Measurement height (mm)
-□
Density of the tested medium (g/cm3)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||