Features:
■High precision, good stability, and not affected by changes in the temperature, pressure, density, viscosity, and conductivity of the measured liquid.
■The sensor has a simple structure, no throttling device, no blockage, and is suitable for measuring liquids containing solid particles, fibers, and suspended solids.
■There are multiple options for liquid contact materials, which can be used for measuring various corrosive liquids.
■It can be installed horizontally, vertically, or diagonally, as long as the measuring tube is filled with liquid and free of bubbles.
■Wide measurement range, range ratio100∶1The range can be modified.
■On site zero calibration is possible without affecting measurement accuracy.
■Low power consumption, less than7W.
■On site LCD displays instantaneous flow rate, cumulative flow rate, flow percentage, fluid flow rate, and fault alarm.
■The Chinese menu allows for parameter viewing and modification according to prompts, and the four button functions are set by the software at any time, making it easy to learn.
■Fault self diagnosis can achieve air traffic control judgment alarm, excitation fault alarm, over range alarm, and output signal fault alarm.
■It can accumulate forward traffic, reverse traffic, and bidirectional traffic difference.
■Automatic conversion of measurement units and decimal places.
■High explosion-proof grade, explosion-proof markExd(ia)iaqⅡCT6.
■Multiple signal output options4~20mA、0~1kHzTheHARTTheRS485Wait.
■Customizable unlined electromagnetic flowmeter.
■One click restore factory parameter settings.
Technical Specifications:
■Sensor section
□Applicable pipe diameter:DN15~DN1000Other calibers are non-standard and can be customized according to user requirements.
□Material of inner lining of measuring tube:F46(Perfluoroethylene propylene, polytetrafluoroethylene),P0(Polyalkanes),PUR(Polyurethane)
□Electrode material:316LTheHcHastelloy alloyc)TheHbHastelloy alloyb)TheTi(Titanium)Ta(Tantalum)
□working pressure:DN15~DN80Caliber:4.0MPa(Standard)
DN100~DN150Caliber:1.6MPa(Standard)
DN200~DN1000Caliber:1.0MPa(Standard)
Exceeding the above pressure standards is non-standard and can be customized according to user requirements.
□Fluid temperature:P0Lining:-20℃~80℃;PURLining:0~50℃
F46Lining:-40℃~130℃(Wide temperature type)130℃~180℃(High temperature type)
□Process connection flange: The flange standard in this book isGB/T9119-2000Other standard flanges can also be customized according to user requirements.
□Grounding ring material:304、321、316TheHcTheTiTheCu
■Converter section
□Measurement range: flow velocity0.1~10m/sFlow rate of each caliber=cross-sectional area of the pipe×flow velocity
□Accuracy level:0.3Level0.5Grade (flow rate)≥0.5m/s),1.0Grade (flow rate<0.5m/s),2.0Grade (flow rate<0.2m/s)
□Conductivity:>5μs/cm
□Output signal:4~20mADC, load≤750Ω
0~1000HzPulse output, active24V,>10mA
RS485
HART
□Working power supply:220VAC±10%,50Hz±1Hz;24VDC±10%
□Power consumption:<7W
□Explosion proof grade:Exd(ia)iaqⅡCT6,Exd(ia)iaqⅡBT4
□Shell protection: integrated:IP65Split type: SensorIP68ConverterIP65
□Ambient temperature-25℃~60℃(Explosion proof type to)50℃)
□ambient humidity:≤85%RH(20℃When)
□Electrical interface size:M20×1.5,1/2NPT(Outer diameter of cable)Φ6~Φ10)