Overview

The BSD series intelligent electromagnetic flowmeter is an electromagnetic induction flow meter composed of sensors and intelligent signal converters. It can measure the volumetric flow rate of various conductive liquids, including highly corrosive liquids such as acids, alkalis, salts, pulp, slurry, wastewater, seawater, and solid-liquid two-phase liquids. This product is mainly used in industries such as petrochemicals, steel, electricity, metallurgy, textiles, food, pharmaceuticals, papermaking, as well as in municipal environmental protection, water conservancy, and other fields. $r $n is recruiting agents and OEMs from all over the world!

Product Details

Features:
  High precision, good stability, and not affected by changes in the temperature, pressure, density, viscosity, and conductivity of the measured liquid.
  The sensor has a simple structure, no throttling device, no blockage, and is suitable for measuring liquids containing solid particles, fibers, and suspended solids.
  There are multiple options for liquid contact materials, which can be used for measuring various corrosive liquids.
  It can be installed horizontally, vertically, or diagonally, as long as the measuring tube is filled with liquid and free of bubbles.
  Wide measurement range, range ratio1001The range can be modified.
  On site zero calibration is possible without affecting measurement accuracy.
  Low power consumption, less than7W.
  On site LCD displays instantaneous flow rate, cumulative flow rate, flow percentage, fluid flow rate, and fault alarm.
  The Chinese menu allows for parameter viewing and modification according to prompts, and the four button functions are set by the software at any time, making it easy to learn.
  Fault self diagnosis can achieve air traffic control judgment alarm, excitation fault alarm, over range alarm, and output signal fault alarm.
  It can accumulate forward traffic, reverse traffic, and bidirectional traffic difference.
  Automatic conversion of measurement units and decimal places.
  High explosion-proof grade, explosion-proof markExdiaiaqCT6.
  Multiple signal output options420mA01kHzTheHARTTheRS485Wait.
  Customizable unlined electromagnetic flowmeter.
  One click restore factory parameter settings.

Technical Specifications:
sensor part
Applicable pipe diameter:DN15DN1000Other calibers are non-standard and can be customized according to user requirements.
Material of inner lining of measuring tube:F46(Perfluoroethylene propylene, polytetrafluoroethylene),P0(Polyalkanes),PUR(Polyurethane)
Electrode material:316LTheHcHastelloy alloyc)TheHbHastelloy alloyb)TheTi(Titanium)Ta(Tantalum)
Work pressureDN15DN80Caliber:4.0MPa(Standard)
DN100DN150Caliber:1.6MPa(Standard)
DN200DN1000Caliber:1.0MPa(Standard)
Exceeding the above pressure standards is non-standard and can be customized according to user requirements.
Fluid temperature:P0Lining:-2080PURLining:050  
F46Lining:-40130(Wide temperature type)130180(High temperature type)
Process connection flange: The flange standard in this book isGB/T91192000Other standard flanges can also be customized according to user requirements.
Grounding ring material:304321316TheHcTheTiTheCu  
Converter section
Measurement range: flow velocity0.110m/sFlow rate of each caliber=cross-sectional area of the pipe×flow velocity
Accuracy level:0.3Level0.5Grade (flow rate)≥0.5m/s),1.0Grade (flow rate<0.5m/s),2.0Grade (flow rate<0.2m/s
Conductivity:>5μs/cm
Output signal:420mADC, load≤750Ω
0
1000HzPulse output, active24V,>10mA
RS485
HART
Working power supply:220VAC±10%50Hz±1Hz24VDC±10%
Power consumption:<7W
Explosion proof grade:ExdiaiaqCT6ExdiaiaqBT4
Shell protection: integrated:IP65Split type: SensorIP68ConverterIP65
Ambient temperature-2560(Explosion proof type to)50
ambient humidity:≤85%RH20When)
Electrical interface size:M20×1.51/2NPT(Outer diameter of cable)Φ6Φ10