uFlexible combination of voltage and current output Type with standard4phase voltage3The phase current output can be easily combined for various types of protection tests. Each phase voltage can output120VCan output three currents in parallel120A, 第4phase voltageUxAs a multifunctional voltage item, it can be set as4plant3U0Or check the voltage of the same period, or output any voltage value.
uConvenient standalone operation The device panel is equipped with a trackball mouse, an optimized keyboard, and a large screenTFTLCD display, built-in all ChineseWindowsPlatform operation software. Ready to use upon startup, easy and fast to operate.
uDual operation mode In addition to standalone operation, the device can also be connected to an external laptop or desktop computer for operation, with the same functionality and truly complete dual operation mode.
uNew high fidelity linear power amplifier The output end has always insisted on using high fidelity and high reliability modular linear amplifiers instead of switch mode amplifiers. It will not cause high or medium frequency interference on the test site, and ensures smooth waveform accuracy from high current to low current throughout the entire process.
uHigh performance host outputPartially adoptedDSPControl, fast computation speed, strong real-time digital signal processing capability, wide transmission bandwidth, high-resolution controlD/Atransformation. The output waveform has high accuracy, low distortion, and good linearity. The device adopts a large number of advanced technologies and precision component materials, and has undergone specialized structural design, resulting in small size, light weight, comprehensive functions, easy portability, and can work immediately after startup. Flow testing is very convenient.
uPowerful software functionality It can complete various large-scale complex verification tasks with high degree of automation, conveniently test and scan various protection settings, perform fault playback, store test data in real time, display vector graphics, and print reports online.
uHaving independenceDedicated DC power output The device is equipped with one channel110Vand220VDedicated adjustable DC power output.
uComplete interface The device panel comes with a built-in keyboard and mouse, which can be operated independently or externally through the keyboard and mouse interface;Also comes with twoUSBMouth andRS232The mouth can communicate with computers and other external devices.
uPerfect self-protection function The heat dissipation structure design is reasonable, the hardware protection measures are reliable and complete, and it has functions such as power soft start, software self diagnosis of faults, and output locking.
uLightweight, compact, highly integrated single machine and integrated structure Adopting a large number of high-tech and carefully designed ultra light and small structures, the whole machineextremelyCompact and lightweight.
AC current output
output accuracy 0.2level
Phase current output (effective value) 0~40A
Triple current output (effective value) 0~120A
Long term allowable operating value (effective value) of phase current 10A
Maximum output power of phase current 450VA
Maximum output power at maximum output of triple current 900VA
Allowable working time at maximum output of triple current 10s
Frequency range (fundamental wave) 0~1000Hz
harmonic order 0~20 time
DC current output
output accuracy 0.5level
current output 0~±10A /Each phase,0~±30A /Three and one
Maximum output load voltage 20V
AC voltage output
output accuracy 0.2level
Phase voltage output (effective value) 0~120V
Line voltage output (effective value) 0~240V
phase voltage/Line voltage output power80VA / 100VA
Frequency range (fundamental wave) 0~1000Hz
harmonic order 0~20time
DC voltage output
output accuracy 0.5level
Phase voltage output amplitude 0~±160V
Line voltage output amplitude 0~±320V
phase voltage/Line voltage output power 70VA / 140VA
Measurement of switch quantity and time
Remarks |
||
Discrete input |
8road |
Empty contact point: 1~20mA,24V Potential contact connection:“0”:0~+6V; “1”:+11 V~+250V |
Switching output |
4to |
DC:220V/0.2A;AC:220V/0.5A |
Time measurement |
measurement range0.1ms~9999s measurementprecision0.1mS |
|