KFD2-STC5-1.2O Beckhoff isolatorPower the HART smart transmitter and transmit the measurement signal to the safe or hazardous area. The active current signal is transmitted to the safe area. Its characteristics are as follows:
1. Single channel;
2. 2-channel isolated output;
3. Electromagnetic compatibility meets NAMUR NE21;
4. According to IEC61508, the safety level can reach SIL2.
KFD2-STC5-1.2O Beckhoff isolatorIts main function is to distribute power for 2-wire intelligent transmitters, andKFD2-STC5-1.2O Beckhoff isolatorTransmitting analog signals. The HART communication overlaid on a 4-20mA current allows for bidirectional transmission.
Brief Function Table of Common Models of Beijiafu Isolators
| On site signal type | model | System side application instructions |
| AI,4-20mA, 2-wire intelligent (or non intelligent) transmitter | KFD2-STC4-EX2 |
Dual channel, active 4-20mA signal input DCS/PLC. Intelligent communication frequency 0-7.5kHz, supporting HART and Brain. |
| AI,4-20mA, 2 or 3-wire intelligent (or non intelligent) transmitter | KFD2-STC4-EX1 |
Single channel, active 4-20mA signal input DCS/PLC. Intelligent communication frequency 0-7.5kHz, supporting HART and Brain. |
| KFD2-STC4-EX1.2O |
Single channel, one in two out signal input DCS/PLC. Intelligent communication frequency 0-7.5kHz, supporting HART and Brain. |
|
|
AO,4-20mA, HART intelligent electrical converter or electrical valve positioner |
KFD2-SCD2-EX2.LK | Dual channel, DCS/PLC output 4-20mA signal, compatible with non intelligent instruments. LED displays circuit faults and outputs fault information through the power rail. |
| KFD2-SCD-EX1.LK |
Single channel, DCS/PLC output 4-20mA signal. LED display circuit malfunction. |
|
| AO,4-20mA, Electrical converter or electrical valve positioner | KFD2-CD-EX1.32 | Single channel, DCS/PLC output 4-20mA signal. |
| Thermocouples: B, E, J, K, L, N, R, S, T types. Thermistor: Pt100, Ni100, 2 or 3 or 4-wire system. Special thermocouples and thermistors for other users. | KFD2-UT2-EX1 |
Single channel, active 4-20mA signal input DCS/PLC. Please order the cold junction compensator K-CJC when using thermocouples; PC configuration, optional PW-PK-KE configuration software package. |
| KFD2-UT2-EX2 | Dual channel, other as above. | |
|
DI, NAMUR type switch signal or dry contact signal. (The isolation barriers in this column are monitored by on-site lines and fault alarms are implemented through the power module.) |
KFD2-SR2-EX2.W | Dual channel, relay dry contact signal input DCS/PLC. |
| KFD2-SR2-EX1.W | Single channel, relay dry contact signal input DCS/PLC. | |
| KFD2-SR2-EX1.W.LB | Single channel, one in two out, 2-channel relay dry contact signal input DCS/PLC. |
|
DO, Most ASCO, Burkert, Crouzet, Parker Lucifer, KV Automation, Samson solenoid valves Herion 2001~2002、 2050 solenoid valve |
KFD2-SL2-EX2.B | Dual channel, DCS/PLC output 24V/?3mA logic signal or dry contact signal, without on-site line monitoring. |
| KFD2-SL2-EX1.B | Single channel, DCS/PLC output 24V/?3mA logic signal or dry contact signal, without on-site line monitoring. | |
| PI, NAMUR type frequency signal or dry contact frequency signal. Speed sensors, flow meters, etc. | KFD2-ST2-EX1.LB | Single channel, 0-24V/?5kHzFrequency signal input DCS/PLC, on-site line monitoring. |
| KFD2-UFC-EX1.D | Single channel, 0.001Hz-5kHz frequency. Send 1 passive frequency signal of 0-24V, 1 active 4-20mA signal with adjustable range, and 2 relay alarm signals to input into DCS/PLC. On site line monitoring. | |
| PI, 0-12V active voltage frequency | KFD2-VR-EX1.18 | Single channel, 4kHz/0-12V active voltage frequency input DCS/PLC. |