E-mail
2837710397@qq.com
-
Phone
18820326175
-
Address
No. 4 Hongbao Road, Dongcheng Street, Dongguan City, Guangdong Province
Dongguan Haoen Testing Instrument Co., Ltd. (Wuhan Branch)
2837710397@qq.com
18820326175
No. 4 Hongbao Road, Dongcheng Street, Dongguan City, Guangdong Province
LED luminous tube thermal shock boxPriceLED luminous tube thermal shock boxManufacturerbrand
1Technical Specifications:
Specification and model: HE-LR-50/80/100/150/252/480
Capacity: 50 liters, 80 liters, 100 liters, 150 liters, 252 liters, 480 liters
Inner box size (width * height * depth): 400 X350X360、500X400X400、500X500X400、600X500X500、700X600X600、800X800X750(MM)
Dimensions (width * height * depth): 1560 X1950X1400、1700X2070X1500、1700X2170X1500、1800X2270X1600、1900X2370X1700、2000X2570X1850(MM)
Test temperature range: S represents -40 ℃ to+150 ℃
W represents: -55 ℃ to+150 ℃
L represents: -65 ℃ to+150 ℃
Low temperature tank temperature range: -55 ℃~-10 ℃, -70 ℃~-10 ℃, -80 ℃~-10 ℃
High temperature tank temperature range:+60 ℃~+200 ℃, with an average heating rate of 5 ℃/MIN
Temperature fluctuation:±2.0℃
Temperature conversion time: 10 seconds
Temperature stabilization time: 5MIN, from room temperature to low temperature 5MIN, from room temperature to high temperature 5MIN
2、 Structural material:
1. Outer wall material: high-quality heat-resistant and cold resistant stainless steel plate (or color steel plate with electrostatic spraying)
2. Inner wall material: high-quality heat-resistant and cold resistant stainless steel plate
3. Box insulation material: rigid polyurethane foam+glass fiber
4.Adopting a multi blade centrifugal circulating fan, reinforced with high and low temperature resistant rotating blades made of aluminum alloy, to achieve forced convection.
5.Air supply method; Horizontal diffusion, vertical heat exchange, arc-shaped cycle.
IIIProgrammable touch screen controller
Adopting a large touch screen display, the screen operation is simple and the program editing is easy.
The controller operation interface is available in both Chinese and English, and the real-time operation curve can be displayed on the screen.
It has a capacity of 100 sets of programs, 1000 segments, and 999 loop steps, with a set Z-value of 99 hours and 59 minutes for each time segment.
After inputting the data and experimental conditions, the controller has a screen lock function to avoid manual touch and shutdown.
Equipped with P.I.D automatic calculation function, it can immediately correct temperature and humidity changes, making temperature and humidity control more accurate and stable.
Equipped with RS-232 or RS-485 communication interface, it can be programmed on a computer to monitor the testing process and perform functions such as power on/off. Optional configuration