Welcome Customer !

Membership

Help

Dongguan Haoen Testing Instrument Co., Ltd. (Wuhan Branch)
Custom manufacturer

Main Products:

ybzhan>Products

Salt spray corrosion testing machine for electroplated parts, salt spray testing chamber

NegotiableUpdate on 12/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Salt spray corrosion testing machine for electroplated parts is also called salt spray corrosion testing machine, salt spray testing machine, salt spray spray testing machine, salt spray testing chamber, small salt spray testing machine, salt spray corrosion testing chamber and 60 salt spray testing machine.
Product Details

Salt spray corrosion testing machine for electroplated partsPriceSalt spray corrosion testing machine for electroplated partsManufacturerbrand

1Technical Specifications

Specification and model: HE-YW-60/90/120/160/200

Capacity: 108 liters, 270 liters, 600 liters, 800 liters, 1200 liters

Inner box dimensions: 600 * 400 * 450, 900 * 600 * 500, 1200 * 1000 * 500, 1600 * 1000 * 500, 2000 * 1200 * 500 (MM)

Dimensions: 1070 * 600 * 1180, 1310 * 880 * 1280, 1900 * 1300 * 1400, 2300 * 1300 * 1400, 2700 * 1500 * 1500 (MM)

Salt bucket capacity: 15 liters, 25 liters, 40 liters, 40 liters, 40 liters

Laboratory temperature: RT~50 ℃

Pressure bucket temperature: RT~63 ℃

Heating rate: Laboratory temperature RT →+50 ℃ ≤ 40 min

Pressure bucket temperature RT →+63 ℃ ≤ 35 min

Relative humidity ≥ 85% HR

Temperature resolution: 0.1 ℃

Temperature deviation: ± 1 ℃

Temperature uniformity: 1 ℃

Temperature fluctuation: ± 0.5 ℃

Spray volume: 1~2mL/80cm ² 1hr (collect for at least 16 hours and take the average value)

Spray pressure: 1.00 ± 0.01kgf/cm ²

酸碱值 PH: 中性6.5~7.2 酸性3.0~3.3

Control time: 1S~9999H can be set arbitrarily

Neutral test method: (1) Laboratory: 35 ℃± 1 ℃ (2) Saturated air tank: 47 ℃± 1 ℃

Acid test method: (1) Laboratory: 50 ℃± 1 ℃ (2) Saturated air tank: 63 ℃± 1 ℃

2、 Characteristics

1. It has an automatic/manual water addition system, which can automatically replenish the water level when the water level is insufficient, and the test will not be interrupted.

2. The temperature controller uses digital display, and the PID control error is ± 01 ℃;

3. Double over temperature protection ensures safe use when the water level is insufficient.

4. The laboratory adopts steam direct heating method, with fast and uniform heating speed, reducing standby time

5. The precision glass nozzle is evenly dropped and diffused through the conical disperser of the spray tower with adjustable fog and fog volume, and naturally falls on the test card, ensuring that there is no blockage of crystal salt.

Similar Product Recommend