Product Introduction:
Anhui Zhongpu Technology Co., Ltd. welcomes you to browse our company website. If you are interested, please let us knowZhongpu Lightning ProtectionThere are questions or needs regarding the series of productsmore helpYou can consult through the service hotline:

IF3 copper lightning rod
The IF3 ionization type pre discharge lightning rod is based on the traditional lightning rod discharge principle, introducing the basic feature of "promoting ionization" as a pre discharge lightning rod, thereby achieving earlier lead discharge than ordinary lightning rods, expanding the protection radius, and improving the safety factor.
In the design process of lightning rods,The technicians of IF3 lightning rods are constantly researching for a goal of "reliability". It is precisely because of this persistent spirit that the IF3 lightning rod has won the trust of many esteemed users.
Characteristics of IF3 pre discharge lightning rod
1The fastest preemptive discharge time86μs, Priority is given to introducing mines into the ground, greatly increasing the protection radius.
2Lightning strikes are more accurate, reducing the probability of lightning strikes hitting non lightning rods.
3At the same installation height, the protection radius is several times larger than that of ordinary lightning rods.
4Pure physical structure lightning rod, with no electronic components inside, no aging, and maintenance free.
5The installation of IF3 pre discharge lightning rod is simple: it is lightweight and does not require the installation of coaxial shielded cables.
6Beautiful appearance, made of high-quality purple copper, with strong flow capacity. Can be applied to meet the needs of high-end users.
Design Description of IF3 Pre discharge Lightning Rod
Installation within ChinaThe IF3 pre discharge lightning rod must strictly comply with the mandatory provisions of the National Lightning Protection Standard of the People's Republic of China - "Code for Design of Lightning Protection of Buildings" (GB50057-94):
1. Determine the lightning protection category of the building based on the area, height, number of mine days, geographic environment correction factor, and building usage nature of the protected building.
2. Determine the selection of one or several IF3 pre discharge lightning rods based on the lightning protection category and building area.
3. The down conductor (lower conductor) should be electrically connected to the main steel reinforcement of the building, or two or more down conductors (lower conductors) should be made according to regulations.
4. The down conductor (lower conductor) should be equipped with a disconnect card and insulated for protection on the nearby ground.
5. The grounding body, grounding resistance, and lightning protection grounding network should be implemented in accordance with the requirements of lightning protection standard GB50057-94.
6. The IF3 pre discharge lightning rod has a warranty period of 20 years.