E-mail
ahzpsd@163.com
- Phone
-
Address
7th Floor, Building C1, Innovation Industrial Park, No. 800 Wangjiang West Road, Hefei City
Anhui Zhongpu Lightning Protection Technology Co., Ltd
ahzpsd@163.com
7th Floor, Building C1, Innovation Industrial Park, No. 800 Wangjiang West Road, Hefei City
Product Introduction:
Anhui Zhongpu Technology Co., Ltd. welcomes you to browse our company website. If you are interested, please let us knowZhongpu Lightning ProtectionThere are questions or needs regarding the series of productsmore helpYou can consult through the service hotline:

Detailed introduction:
To ensure safe and reasonable use for usersThe PDC series active early discharge lightning rod hereby makes the following commitments regarding related services:
1 Every project should be thoroughly and carefully reviewed, discussed, and designed.
2 Provide reasonable suggestions based on the actual situation of the user and submit the plan.
3. Efficient and fast service.
4. Continuously follow up on the actual installation situation.
5. Submit the completion report.
6. Tracking service.
product mix
1. Central collection pole
2. Reflector
3. Trigger device
4. Exciter
5. Exciter fixing plate
6The exciter, reflector, and central collection rod are insulated.
7The reflector and central collection mark have good electrical connection with the earth.
8The exciter base is made of synthetic resin and is suitable for any corrosive environment.
Product Features
There are four types of PDC early discharge lightning rods (as shown in the table below), all made of stainless steel material, corresponding to different protection ranges, and each model has different performance characteristics.
The advantages include:
Non electronic, long lifespan
100% discharge rate
High protection level
Can ensure electrical continuity and functional continuity after repeated lightning strikes and discharges
Capable of early discharge function
The quality of protection will not change after lightning strikes
No electronic system will be damaged by surge impact
Selection of models with different protection radii
Fully active interception lightning system
When there is lightning, it will activate itself
beautiful appearance
Safe and reliable
No maintenance required
Active early discharge lightning rodWorking principle of PDC series:
The PDC series lightning rod mainly absorbs and stores energy from the natural electric field through the exciter EXCITERS. The reflector Reflector and lightning rod tip have good electrical connection with the ground and are in an equipotential state. So usually, there is an electric field strength between the exciter and the emitter. Before a lightning flash occurs, the electric field strength increases rapidly, and the potential difference between the exciter and the reactor is roughly equivalent to the potential between the thunderstorm and the ground. The rapid increase in voltage drop between them will cause ignition at the tip and ionize the air around the tip, forming a tip discharge phenomenon.
Central collection rod and exciter of lightning rodThe rapid increase in electric field between ExcitERS causes ionization of the air at the tip, which can be discharged in a very short and accurate time. Due to the presence of a large number of electric ions, the natural Corona effect is reduced, creating an expected upward discharge channel that can quickly/safely intercept lightning and safely release it to the ground.
Calculation formula for the protection radius of PDC active early discharge lightning rod
set upIf the start preemptive time of IPDC is Δ T, then the preemptive distance of the upstream leader Δ L=V * Δ T
according toThe calculation method provided by NFC-17-102 standard calculates the protection radius Rp according to the following formula:
The distance of D electric shock depends on the level of the protected building. For Class I, II, and III protected objects, the D values are 20m, 45m, and 60m, respectively.
H is the height from the top of the lightning rod to the protected plane.
Δ T is calculated and evaluated through testing, as shown in the table above
V=106m/s
ΔL=V*ΔT
Note: Currently, there are no testing and acceptance standards for early discharge lightning rods in China. Please follow the height radius of the lightning rod(Calculation of relevant standards in GB50057 "Code for Design of Lightning Protection of Buildings".
Technical Parameter
|
model
|
Early discharge time △ T
|
|
Needle height
|
weight
|
Number of needle wing tips
|
Number of needle tips
|
|
|
TG-PDC3.3
|
25 microseconds
|
|
663mm
|
3.9Kg
|
3 pieces
|
9 pieces
|
|
|
TG-PDC4.3
|
34 microseconds
|
|
723mm
|
5.2Kg
|
4 pieces
|
16 pieces
|
|
|
TG-PDC5.3
|
43 microseconds
|
|
723mm
|
6.3Kg
|
5 pieces
|
25 pieces
|
|
|
TG-PDC6.3
|
50 microseconds
|
|
753mm
|
8.9Kg
|
6 pieces
|
36 pieces
|