Welcome Customer !

Membership

Help

Huai'an Pruda Testing Equipment Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Linear cooling test chamber, rapid temperature change test chamber, rapid cooling

NegotiableUpdate on 03/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Introduction to Linear Cooling Test Box/Rapid Cooling Test Box/Rapid Temperature Change Box System This series of environmental test boxes can provide a simulated environment for users to inspect and test electronic and electrical components, spare parts, or related industry experimental departments, providing necessary conditions for the accuracy and consistency (repeatability) of test data
Product Details

Introduction to Linear Cooling Test Chamber/Rapid Cooling Test Chamber/Rapid Temperature Change Chamber System
This series of environmental experiment boxes can provide a simulated environment for users to inspect and test electronic and electrical components, spare parts, or experimental departments in related industries, providing essential conditions for the accuracy and consistency (repeatability) of test data. This product has simple operational performance and reliable equipment performance, the most advanced and convenient measuring device, temperature controller, and adopts advanced Chinese LCD display screen touch screen. It can perform various complex program settings, and the program settings adopt dialogue mode, making the operation simple and fast. It can achieve automatic operation of the refrigeration machine, maximize automation, reduce the working time of operators, and can automatically start, stop, and operate at any time. The work of each system (fan, refrigeration, heating) is centrally controlled by the touch screen human-machine interface. The overall assembly is carried out at the customer's end, with convenient transportation and placement, and on-site debugging and acceptance are carried out at the customer's end to ensure the performance of use at the customer's end; High degree of structural integration, short assembly and debugging time on the client side; Scientific air circulation design ensures uniform indoor temperature and avoids any dead corners; A complete safety protection device avoids any potential safety hazards and ensures the long-term reliability of the equipment; Each product is customized according to customer requirements, ensuring the efficiency and energy saving of the equipment.
Linear cooling test chamber/Linear cooling test chamber/Rapid temperature change chamberHeating system
1. Heating is achieved through the use of heating tubes, and solid-state relays are employed for the execution components.
Control system for ultra-low temperature test chamber
1. Setting method: Touch, click
2. Display mode: Color LCD touch screen with Chinese display
3. Setting and display resolution: temperature (0.1 ℃); Time (1 minute)
4. Graphic display: Fully display the set program curve.
5. Set parameter storage time: After fully charged, data can be saved for 5 years.
6. Number of programs: 1-10 (maximum 10 programs).
7. Program segments: 1 to 64 segments per program; Can run by group connection.
8. It can automatically prompt users to correctly set temperature, humidity, and time parameters.
9. There is a dedicated maintenance interface for debugging and maintaining equipment with program running and maintenance functions.
10. It has the function of waiting for program execution.
11. It has program skip function.
12. It has a program stop function.
13. It has a power-off recovery function.
14. It has the function of locking the running interface. Recording function: It can record curves and experimental data within 100 days, and can query the temperature situation at every moment within 100 days in detail. It can be exported using USB 2.0 and printed on a PC to generate data reports (equivalent to the function of a paperless recorder). It also has a self check function for startup faults.
15. Computer monitoring system: The control system can achieve data transmission and monitoring functions through the computer Ethernet communication interface. Note: Free software upgrades will be provided in the future
Linear cooling test chamber/Linear cooling test chamber/Rapid temperature change chamber refrigeration system
1. System concept: This type of laboratory adopts industry-leading temperature balance technology (cooling without heating), which balances temperature control through energy regulation technology without the need for additional heating during cooling and low-temperature balance. Energy regulation technology, also known as PID control, regulates refrigerant flow by adjusting the mass of refrigerant entering the evaporator per unit time to achieve precise control of refrigeration power and temperature in the laboratory.
Compared to the previous "balanced temperature control method" of heating and cooling at the same time, the energy consumption is very high. The application of this technology can minimize customers' operating costs and extend the lifespan of compressors to the greatest extent possible. It can save users a considerable amount of electricity expenses during the product lifecycle (depending on the actual frequency of use by customers)
3. Refrigeration hardware: using "Taikang" fully enclosed compressor.
4. Refrigerant: Environmentally friendly refrigerants R404a and R23 are used.
5. Refrigeration evaporator: A corrugated fin refrigeration evaporator is used, located in the air duct interlayer at one end of the test chamber, and is forced to ventilate by a blower motor for rapid heat exchange.
6. Auxiliary components: Other auxiliary components in the refrigeration system of this test chamber, such as solenoid valves, filters, etc., are also imported by our company; If using electromagnetic valves, bypass valves, etc. from Italian CASTEL, other accessories are also selected from well-known domestic brands of refrigeration accessories.
7. Low temperature pipeline: High quality oxygen free copper pipes and nitrogen filled welding are used for low-temperature pipelines (traditional methods use ordinary copper pipes, and direct welding methods can easily cause oxides to form on the inner wall of the copper pipes, causing blockages in the refrigeration system and preventing or slowing down the cooling of the test chamber)
There is a condensate drain tray at the bottom of the refrigeration system and it is discharged outside the box.
8. Vibration reduction: Adopt compressor rubber pads or spring vibration reduction measures; The refrigeration system pipeline adopts the method of adding R and elbows to avoid the deformation of copper pipes caused by vibration and temperature changes, which may cause the refrigeration system pipeline to rupture.
9. Noise reduction: Special wave shaped sound-absorbing sponge is used for sound absorption.
Linear cooling test chamber/Linear cooling test chamber/Rapid temperature change chamber air duct system
To ensure a high uniformity index, the test chamber is equipped with an internal circulating air supply system and a dedicated air duct. Inside the air duct interlayer at one end of the studio, there are devices such as heaters, refrigeration evaporators, and fans distributed. Multiple fans are used to circulate the air inside the box. When the fans are running, the air in the working chamber is sucked into the air duct from the bottom, heated/cooled, and uniformly blown out. The air exchanged with the test sample in the working chamber is then sucked into the air duct and repeatedly circulated to meet the temperature setting requirements.
Specification of rapid temperature and humidity test chamber

model TCK50 TCK-100 TCK-150
Studio Size 350*450*320 450*550*405 500*600*500
model TCK-225 TCK-400 TCK-1000
Studio Size 500*750*600 600*850*800 1000*1000*1000
■ Performance
system Balanced Temperature and Humidity Control System (BTHC)
temperature range -70℃-60℃-40℃-20℃~+100℃+150℃
Humidity range 20~98%RH
temperature fluctuation ±0.5℃
Temperature deviation When the temperature is between 100 ℃ and+150 ℃, it should be within the range of ± 1.5 ℃
temperature fluctuation ±2.5%RH
Degree uniformity ±3.0%RH(>75%RH) ±5.0%RH(≤75%RH)
heating up time ≥2~3℃/min
Cooling time 1℃/min/3℃/min/5℃/min/10℃/min/
■ Composition
Housing material Texture treated stainless steel (SUS304) or high-quality cold-rolled steel plate with electrostatic spraying
Inner box material Stainless steel plate (SUS304)
Thermal insulation material High density polyurethane foam+glass fiber
Observation window Internal embedded glass for heating
cable hole Inner diameter Φ 50
heater Nickel chromium alloy electric heater
humidifier Stainless steel double set heating tube
Mixing blower sirocco fan
motor Condenser type
Caster wheels 4 movable casters with brakes
■ Refrigeration system
refrigeration machine European and American fully enclosed rotary compressor
refrigerant Environmentally friendly refrigerant R404+R23
condenser finned-tube evaporator
Cooling method Mechanical compression single-stage cascade refrigeration (air-cooled condenser)
■ Control system
Temperature and humidity controller Imported temperature and humidity controller
Operation interface Digital tube display
operation Fixed value operation
Setting method Touch or button type
resolution Temperature: ± 0.1 ℃ Humidity: ± 1% RH
sensor PT100 thermistor
control mode pid control
Communication function (R232 communication can control temperature and humidity through computer)
Fu Fu Function Alarm display function, power outage protection function, upper limit temperature alarm function, timing function (automatic start and stop), diagnostic function, curve recording display function
■ Water supply
Water supply method Pump lifting
Filler Convenient rear mounted water inlet
Water storage tank Concealed stainless steel fixed water storage tank (approximately 15 liters)
■ Safety devices
Humidifier dry burning protection, independent protection, water protection, compressor overload, overheating, overcurrent protection, refrigerant high voltage protection switch, current circuit breaker, leakage protection
Environmental temperature for use +5~+35℃
power supply AC380 ± 10% V 50 ± 0.5Hz three-phase four wire+grounding wire (AC220V can also be selected, please specify when ordering)
■ Attachment
1 cable hole (50) cover, 2 sets of grid openings, 2 safety pipes, 1 overflow water pipe, 1 set of product manual
■ Optional accessories
Recorder RS485 or RS232 communication interface, software