Magnetic flap level gauge manufacturerIt uses a magnetic float as the measuring element and a magnetic steel driven flip column display, without the need for energy. Suitable for various environments ranging from low temperature to high temperature, vacuum to high pressure, etc. It is an ideal liquid level measurement product for industries such as petroleum and chemical. The magnetic replica level gauge is equipped with upper and lower limit switch outputs, which can achieve remote alarm and limit control. The magnetic replica level gauge is equipped with a transmitter, which can achieve remote indication, detection, and control of liquid level. According to the different installation positions of the container, two forms are provided: side mounted and top mounted. Provide stainless steel andABSTwo materials of engineering plastics; of whichABSEspecially suitable for corrosive media such as acids and alkalis.
Magnetic flap level gauge manufacturerStructural features:
lBasic type
According to the principle of buoyancy, the float in the measuring tube moves up and down with the rise and fall of the liquid level. The permanent magnetic steel inside the float drives the red and white flip columns to flip through magnetic coupling 180 When the liquid level rises, the flip column changes from white to red, and when it falls, it changes from red to white, thereby indicating the liquid level.
lUpper and lower limit switch output
By using a magnetic float to move with the liquid level, the reed switch installed at the set position of the liquid level gauge riser is activated to achieveON-OFFControl or alarm.
lElectric remote transmission
Install a transmitter on the magnetic replica level gauge. The transmitter consists of two parts: a sensor and a converter. It moves up and down through a magnetic float and uses magnetic coupling to sequentially move the measuring components inside the conduit, obtaining changes in resistance signals and converting them into0~10mAperhaps4~20mAThe standard current signal output is used to connect with digital display instruments or computers for remote display.
Main technical parameters of magnetic flap level gauge manufacturer:
|
Installation form and content
|
Side mounted
|
Top mounted
|
|
Installation spacing
(Measurement range)
|
500,800,1100,1400,1700,2000,2500, 3000,3500,4000,4500,5000,5500,6000
|
500,800,1100,1400,1700,2000,2500,3000
|
|
Working pressure
|
0.6,1.6,2.5,4.0MPa
|
0.6,1.6,2.5MPa
|
|
Medium density
|
≥0.5g/cm 3
|
≥0.76g/cm 3
|
|
Connecting flange
|
stainless steel
|
flange20-40(D N 20 P N 4.0)
(GB9119-88)
|
flange200-25(D N 200 P N 2.5)
(GB9119-88)
|
|
ABS
|
flange20-10(D N 20 P N 1.0) (GB9119-88)
|
flange200-6(D N 200 P N 0.6)
(GB9119-88)
|
|
Main material
|
ABS(Work pressure)0.6MPa)1Cr18Ni9T
|
|
medium temperature
|
-40 ℃~100℃ (ABS: -40℃~80℃ )
|
|
ambient temperature
|
-40 ℃~+70℃
|
|
Indication error
|
±10mm
|
|
Viscosity
|
≤1st(10 - 4 m/s)
|
|
Upper and lower limit switch output
|
1. Control sensitivity: 10mm 2.Output contact capacity: AC220V2A 3.Contact life: 5×10 4
|
|
Continuous electric remote transmission
display
|
4~20mA
1. accuracy:±1.5%
2. Output Load: 750
3. output signal: 0~10mAoutput, 220VACpower supply
4~20mAoutput, 24VDCtwo-wire system
4. Explosion proof featuresiaⅡCT4Intrinsically Safe
|
The composition of the magnetic flap level gauge manufacturer is as follows:
|
|
Magnetic replica liquid level gauge
|
|
|
code
|
Installation method
|
|
1
|
Side mounted
|
|
2
|
Top mounted
|
|
|
code
|
Material
|
|
1
|
ABS
|
|
2
|
1Cr18Ni9Ti
|
|
|
code
|
nominal pressure
|
|
1
|
0.6MPa (only applicable when the main material is ABS)
|
|
2
|
1.6MPa
|
|
3
|
2.5MPa
|
|
4
|
2.5MPa
|
|
|
code
|
type
|
|
1
|
Basic type
|
|
2
|
Equipped with upper and lower limit switch outputs
|
|
3
|
Live remote transmission (0~10mA output, 220V, AC)
|
|
4
|
Live remote transmission (4-20mA output, 24V, DC)
|
|
5
|
Equipped with intrinsic safety explosion-proof remote transmission (4-20mA output, 24V, DC)
|
|
|
|
Installation spacing (measurement range)
|
|
|
L1
|
Installation depth (top mounted) (0~4000mm optional)
|
|
|
Medium density
|
g/cm3
|
|
AKLT- 1 1 1 1 L= □ L= □ p= □
|
|