The Merck air microbiological detection system is an economical, compact, and portable MAS-100 EcoMAS-100 air microbiological detection system based on the Anderson impact principle (1958), with an impact speed of 20m/s, equivalent to Anderson impact level 6. The suction device inside the instrument sucks in air through a porous cover (sampling head) and impacts it onto a 90mm culture dish or a 60mm contact dish, capturing microorganisms in the air onto the agar medium. After taking out the culture dish and culturing it under suitable conditions, count the bacterial colonies.
Product Details

Domestic free dedicated line For more information, please visit the website of Shenzhen Fiteli Technology Co., Ltd!

Merck Air Microbial Detection System economy compact and portable

MAS-100 Eco

Merck Millipore

Merck Millipore is the life sciences division of Merck Group in Germany. To provide a wide range of high-performance products, services, and professional collaborations for the field of life sciences. From a professional perspective and collaboration in the fields of new science and engineering, Merck Millipore is one of the top three global partners in life science research and development. Merck Millipore will become a strategic partner for customers in the life science field, helping them enhance their capabilities in life sciences. Merck Millipore is headquartered in Billerica, Massachusetts, USA.

MAS-100The air microbial detection system is based on Anderson's impact principle(1958)Impact velocity20m/sEquivalent to Anderson impact level6Grade. The suction device inside the instrument sucks in air through a porous cover (sampling head) and impacts it90mmCulture dish or60mmMicroorganisms in the air are exposed to the disc upon contactcaptureOn agar medium. Remove the culture dish and cultivate it under suitable conditions
Afterwards, count the bacterial colonies.

MAS-100comply withISO 14698-1/2Standard, the standard speed is100L/min.

Sampling accuracy

The volume of sampled air can be affected by various reasons, such as the volume of culture medium poured into the culture dish, pressure and temperature factors in the environment
Changes in air density, sampling heads of different specifications.

MAS-100The air microbiological detection system is currently one of the * * * sampling instruments on the market,MAS-100Series(MAS-100 EcoExcluding those with * * air flow sensors. During the entire sampling process, the flow sensor transmits signals to the motor by monitoring changes in real-time air flow values, and controls the volume of inhaled air by adjusting the motor speed to ensure a stable sampling speed100L/min.

parameter

MAS-100 Ecoparameter

High (excluding handle)

14cm

diameter

11cm

High (including handle)

18cm

weight

1.4kg

material

Anodized aluminum

Sampling head diameter

10cm

Nominal airflow velocity

100L/min +4.0%

Standard sampling volume

10.20.50.100.200.500L

Sampling volume setting range

1-1000L

rechargeable battery

2NiMH rechargeable batteries,1.2V

electric motor

6V

display screen

Alphanumeric LCD display,2*8byte

battery life

Real time clock 10year

CEcertification

EN 50081-1:1992+EN 50082-1:1997

EN 50081-2:1993+EN 50082-2:1995+prEN50082-2:1996

Power supply

100-240V,50-60KHz

output

5V DC/500mA


MAS-100 EcoyesMAS-100The economic selection in the series of products is mainly applied in the food and beverage industry and related industries.. It is based on the Anderson impact method principle, using a high-performance suction device to extract air through a porous cover (sampling head), allowing microorganisms in the airflow to collide and adhere to the surface of the agar medium in a standard culture dish. After completing the sampling period, place the culture dish under suitable conditions and determine the total number of bacterial colonies. Different bacterial colonies can also be detected by changing the type of culture medium.

MAS-100 Ecostrictly in accordance withISO14698-12003 Standard design, sampling speed100L±4%The diameter of the culture dish used is90-100mmIts suction flow rate is per minute100 Raise. Each collection cycle can collect multiple data points2000 Rising air. This performance enables sampling to be conducted under strict requirements for monitoring sterile and clean rooms. The impact velocity (the speed at which microorganisms in the air collide with the surface of agar) is approximately11rice/Seconds, equivalent toAndersenSampler's5 Level, can guarantee>1 Micro particles are collected. There is no significant difference in the collection rate of microorganisms between this air sampling system and other methods.



advantage
Small and compact design
The battery can be a general commercially available battery
The handle can also serve as a bracket, allowing for the adjustment of sampling angles
portable


Technical Specifications
Sampling speed 100 rise/divide±4%
The fully loaded operation time of the rechargeable battery is about2 Hours, disposable battery operation time is about5 hour
Anodized aluminum shell
The sampling head can be wet and hot, and the body can be wiped with a cleaning agent**
Use a digital calibratorDA-100Verification, convenient and accurate


software part
5
A preset volume, within11000 riseAdjustable between any options
Easy to operate
Real time date and time
Battery level reminder function

Specially designed for detecting microbial content in compressed gases, with explosion-proof design

Domestic free dedicated line For more information, please visit the website of Shenzhen Fiteli Technology Co., Ltd!