Welcome Customer !

Membership

Help

Shenzhen Fiteli Technology Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Microbial detection system for water quality

NegotiableUpdate on 05/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The Fitlylab Water microbiological testing system has been certified by ISO/TR13843:2000 Water Quality Standard - Microbial Certification Method and accredited by the authoritative ISO 16140:2003 "Microbiology of Food and Animal Feed" alternative method. It meets the internal certification of ISO/IEC 17025:2005 standard. The Fitlylab Water Microbial Detection System consists of MBS-MR host, laptop, Fitlylab Chinese operating software, VL microbial detection bottle, water filtration system, etc. It can quickly and quantitatively detect the total number of bacterial colonies, total coliforms (coliforms), Escherichia coli (Escherichia coli), heat-resistant coliforms (fecal coliforms), Pseudomonas aeruginosa (Pseudomonas aeruginosa), Salmonella, Staphylococcus aureus, Enterococcus (Streptococcus faecalis) in water quality. One machine can simultaneously detect multiple items and samples.. Fool type, no pre-treatment required for samples, direct sample testing, complete, fast, accurate, no need for laboratory or professional personnel for safe operation, and the instrument automatically generates reports.
Product Details

Fitlylab-WaterWater quality microbiological detection system, throughISO/TR13843: 2000Water Quality StandardsMicrobial authentication method certification,

Through authoritative certificationISO 161402003“Microbiology of Food and Animal FeedCertification of substitute law,comply withISO/IEC 17025:2005Standard internal certification.


Fitlylab-WaterMicrobial detection system for water qualityfromMBS-MRHost, laptop, FitlylabChinese operating software,VLMicrobial detection bottle, water quality filtration system, etc


Can quickly and quantitatively detect the total number of bacterial colonies and total coliform bacteria in water quality(coliform bacteria)Escherichia coli (Escherichia coli), heat-resistant coliform bacteria group(Fecal coliform microbiota)Pseudomonas aeruginosa (Pseudomonas aeruginosa), Salmonella, Staphylococcus aureus, Enterococcus (Streptococcus faecalis), one machine can simultaneously detect multiple items and samples.. Fool type, no pre-treatment required for samples, direct sample testing, complete, fast, accurate, no need for laboratory or professional personnel for safe operation, and the instrument automatically generates reports. For samples with small requirements, simply add the water sample to the testing bottle. For samples with large quantities, use the membrane filtration method and throw the filtered membrane into the matching testing bottle.Fitlylab-WaterThe rapid detection system for water quality microorganisms is developed by the Institute of Physics at the University of Rome and the Italian Institute of Nuclear Physics(INFN)Jointly developed with the Institute of Biology at the Third University of Rome. It is the crystallization of high-tech technology that replaces traditional microbial detection methods.Through authoritative certificationISO 161402003“Microbiology of Food and Animal FeedCertification of substitute law,comply withISO/IEC 17025:2005Standard internal certification, passedISO/TR13843:two thousandWater Quality Standards

Microbial authentication method certification.Detectable items:Total bacterial count, total coliform group(coliform bacteria)Escherichia coli (Escherichia coli), heat-resistant coliform bacteria group(Fecal coliform microbiota)


Pseudomonas aeruginosa (Pseudomonas aeruginosa), Salmonella, Staphylococcus aureus, Enterococcus (Streptococcus faecalis)The detection steps can be summarized


Complete the following 4 steps: 1 Dissolve the reagent in sterile water, 2 Add samples, 3 put them into the machine for testing and obtain a report, 4





After testing, detect bottle killingFor small water sample sizes, add directly1ML

Put the water sample into the detection bottle

For samples with a large volume of water samples, another membrane filtration method is used for sampling:Water sample quantity100ML




1


Use a disposable needle filter for the inside, and after filtering, remove the filter membrane and place it in a testing bottleA large amount of water sample(100ML



Filter with a dedicated filtration system and then throw the filter membrane into the detection bottleFitlylab-WaterRapid detection system for water quality microorganisms

1Features:water qualityTotal bacterial count, total coliform group(coliform bacteria)Escherichia coli (Escherichia coli), heat-resistant coliform bacteria group(Fecal coliform microbiota)

Quantitative detection of Pseudomonas aeruginosa, Salmonella, Staphylococcus aureus, Enterococcus (Streptococcus faecalis), and other bacteria;2: MBSBrick technology includes dish culture method (special medium) and enzyme method(β -Glucosidase)**

3Combining the advantages of techniques such as antigen search and gene search;2Detection speed: It is the speed of traditional inspection methods10

4Double; Can detect solid, liquid, surface, paste, and slurry samples

58.Each detection position is independently operated to meet the needs of detecting different samples and microorganisms

6Each detection bit is independent, reusable, and can automatically select and control the temperature of the inspection item;

7Simultaneous detection of three light waves (blue, green, red);1Sensitivity up to detectableTarget microorganisms, namely1CFU,High specificity99.999%

8The sample detection operation is simple, and most samples can be directly added1gor1m

9The sample does not require pre-treatment;No need for human supervision, automatically generate detection reports and store them in the database, or choose to create reports as neededPDF

10Save format separately;

11The detection bottle is a closed type detection, and all detection processes are harmless to the human body and can be used in general environments; Qualitative analysis of qualified values can be set according to customer requirements, or it can be done as is without restrictions

12Quantitative analysis of samples;The detection bottle comes with its own****Function: After testing, the detection bottle has been tested

13Afterwards, it can be disposed of safely and harmlessly according to the laboratory's standard waste disposal procedures;The operating software has been upgraded toFitlylab

14Chinese version, customers who purchase can receive long-term free updates; Three simple operation steps, foolproof, no need for professional operators

15The instrument is portable and can be used for testing anytime, anywhere100%

16Quantitative analysis;: Through authoritative certificationISO 161402003“Microbiology of Food and Animal Feed replaceCertification of Law,comply withISO/IEC 17025:2005Internal certification of standards (general requirements for testing and calibration laboratory capabilities);passISO/TR13843: 2000Water Quality Standards