E-mail
jsmichao@sina.com
-
Phone
18852469957
-
Address
Baoying County, Yangzhou City, Jiangsu Province
Jiangsu Mi Chao Power Equipment Co., Ltd
jsmichao@sina.com
18852469957
Baoying County, Yangzhou City, Jiangsu Province
1Multi functional calibratorKey Features:
1. It can semi automatically or manually inspect the basic errors of various power frequency meters (voltmeter, ammeter, power meter, frequency meter, power factor meter, phase meter) in the power system, as well as the changes caused by factors such as voltage, current, waveform, and power factor.
The power supply section can generate distortion waves with harmonics ranging from 2nd to 31st, and the number, order, amplitude, and phase of harmonics on the fundamental wave can be programmed.
The working frequency band of the 3 power amplifiers is 40Hz-1kHz, with good linearity. The current amplifier is a constant current source, and the voltage amplifier is a constant voltage source. Due to its lightweight, this device is more suitable for on-site verification.
4 has a USB interface. Through the upper computer software (optional), this device can be controlled by a computer for automatic or manual inspection, and the results can be processed and managed.
5. Equipped with a large capacity non-volatile memory, it can store 300 pieces of raw data from the tested instruments for reference and uploading.
6. The electricity meter can be calibrated by detecting the load point or selecting the point according to the electricity meter.
IIMulti functional calibratorTechnical Indicators:
1. AC voltage range of 50V, 100V, 200V, 400V, 600V, with a maximum output capacity of 20VA;
2 AC current ranges of 0.5A, 1A, 2.5A, 5A, 10A, 20A with a maximum output capacity of 20VA;
3. AC voltage and current regulation range: 0-130% FS, regulation fineness: 5 × 10-5;
4. Accuracy of AC voltage and current at power frequency of 0.05% FS;
5 active power (50V~400V) with an accuracy of 0.05% FS;
6 reactive power (50V~400V) accuracy 0.1% FS;
The phase accuracy of 7 currents for the same phase voltage is 0.050;
The frequency adjustment range is 45-65Hz, the adjustment fineness is 0.001Hz, and the accuracy of the setting value is 0.01Hz;
9-phase adjustment range 0~359.990, adjustment fineness 0.010;
The power factor adjustment range is 0 to ± 1, and the adjustment fineness is 0.0001; Accuracy of setting value 0.0005;
10 AC voltage and current output waveform distortion ≤ 0.3%;
11. AC voltage, current, and power output stability ≤ 0.01% FS/60s;
12 harmonics 2-31 times, amplitude 0-40%, phase fineness of each harmonic 0.010 · N (N is the harmonic order);
13 DC voltage range: 75V, 75V, 150V, 300V, 500V, 1000V, with a maximum output capacity of 20W;
14 DC current ranges of 0.5A, 1A, 2.5A, 5A, 10A, 20A with a maximum output capacity of 20W;
15 DC voltage and current regulation range 0-120% FS (1000V range 0-105% FS), regulation fineness 5 × 10-5;
16 DC voltage and current output stability ≤ 0.01% FS/60s (peak to peak);
17 DC voltage setting accuracy of 0.05% FS;
18 DC current setting accuracy of 0.1% FS;
19 DC 75mV output (load ≥ 5 Ω) with an accuracy of 0.1% FS;
The comprehensive error of the 20 meter measurement (50V~400V) is 0.05% (pulse output: three-phase rated value=6Hz);
21 working power supply single-phase 220V ± 10%, 50Hz ± 5%;
The operating environment temperature is 200C ± 100C, and the relative humidity is ≤ 85% RH;