The German MRU/Mingyou OMS420 integrated online monitoring system for oxygen concentration and combustion efficiency is based on the ZrO2 measurement principle. It can choose to measure the concentration of incompletely burned combustibles with a Coe sensor, forming a complete online monitoring system for combustion efficiency. The measurement unit is installed outside the flue, and the flue gas is introduced into the measurement unit through a reverse flow pipe. The original flue gas returns to the flue. The online zirconia oxygen analyzer is divided into integrated, remote display, high temperature, etc.
Online zirconia oxygen analyzer OMS420-R
The OMS420 integrated online monitoring system for oxygen concentration and combustion efficiency, manufactured by MRU/Mingyou Company in Germany, is based on the ZrO2 measurement principle. It can be equipped with a Coe sensor to measure the concentration of incompletely burned combustibles, forming a complete online monitoring system for combustion efficiency. The measurement unit is installed outside the flue, and the flue gas is introduced into the measurement unit through a reverse flow pipe. The original flue gas returns to the flue.
The integrated online monitoring system for oxygen concentration and combustion efficiency can choose between timed automatic calibration function and automatic soot blowing function.
characteristic
Compact and sturdy structure
The transmitter can be replaced on-site without the need to remove the sampling probe from the flue
Real concentration measurement in wet state, which can be converted into dry state data
Automatic soot blowing function can be selected
Optional online automatic calibration or manual calibration function
No need for reference oxygen
High precision, long lifespan
Technical Parameter
★ Measurement parameters: oxygen concentration and combustible material concentration in flue gas
★ Measurement range: Oxygen O2: 0-25%
Combustible concentration: 0-1000ppm COe (option)
★ Accuracy: ± 0.2% O2 or ± 5% reading, take the larger value
± 50ppm COe or ± 20% reading, take the larger value
★ Repeatability: not greater than ± 1% FS
★ Preheating time: 30 minutes
★ Response time:<10s
★ Service life: greater than 5 years
★ Analog output: Two channels of 4-20 mA, users can set the corresponding range
★ Digital output: RS485 (Modbus protocol)
★ Power supply: 18-24 VDC, 90-100W; 100-240VAC (OMS420RT model)
★ Calibration air interface: threaded connection, can connect 6/4 mm pipes, calibration can be done manually or automatically through the pneumatic unit PU420
★ Anti blowing air path interface: quick connector, 8mm pipe, requires connection of 6-8 bar compressed air
★ Working environment temperature (electronic part): -20 ℃ ---+60 ℃
★ Protection level: IP 65
System structure form
OMS420 type:
★ Display and ZrO2 sensorIntegrated
★ 24VDC power supply
★ Guide pipe with installation flange
★ Optional: Backblowing, COe sensor, and PU420 pneumatic unit
OMS420RT type:
On site ZrO2 sensor,remote indication
★ Guide pipe with installation flange
★ 100-240VAC power supply 10m connecting cable
★ Optional: Backblowing, COe sensor, and PU420 pneumatic unit
OMS420HT type for high temperature use:
On site ZrO2 sensor,remote indication
★ 100-240VAC power supply
★ 10m connecting cable
★ Install flange with sprayer and ceramic guide pipe
★ Optional: Backblowing, COe sensor, and PU420 pneumatic unit
Option: PU420 Pneumatic Unit
The PU420 pneumatic unit is installed near the detector (5m) and connected to OMS420N through special cables and pneumatic pipelines. Clean air and cylinder gas are automatically or manually connected to the calibration interface. The entire calibration process does not require the detector to be removed from the flue.
Online residual oxygen analyzer, online oxygen detector, online oxygen analyzer, online zirconia oxygen analyzer, oxygen monitoring system
Wuhan Service Center