PT100 thermistor manufacturer

NegotiableUpdate on 01/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
PT100 thermistor manufacturers generally refer to the ability of the protective tube to withstand static external pressure without breaking at room temperature, and the experimental pressure is generally 1.5 times the nominal pressure. In fact, the allowable nominal pressure is not only related to the material, diameter, and wall thickness of the protective tube, but also to its structural form, installation method, insertion depth, as well as the flow rate and type of the measured medium.
Product Details

PT100 thermistor manufacturer

Armored thermal resistance pt100-WZPK-163S pt100-WZPK-164S pt100-WZPK-165S pt100-WZPK-166S pt100-WZPK2-165SA pt100-WZPK2-166SA pt100-WZPK-263S pt100-WZPK-264S pt100-WZPK-265S pt100-WZPK-266S pt100-WZPK2-265SA pt100-WZPK2-266SA
pt100-WZPK-363S pt100-WZPK-364S pt100-WZPK-365S pt100-WZPK-366S pt100-WZPK2-365SA pt100-WZPK2366SA pt100

PT100 thermistor manufacturer model description:

W

Z

P

K

Specifications

Content





-

1


No fixed device

2


Fixed card sleeve thread

3


Movable card sleeve thread

4


Fixed card sleeve flange

5


Movable card sleeve flange

Installation fixed form

0


Simplified form

2


Splash proof type

3


waterproof type

6


socket-type

7


Wire type with connecting wires

Form of junction box

(Free end form)

3


φ3

4


φ4

5


φ5

6


φ6

diameter

Introducing components



Design Serial Number


W

Z

P

K

-

S

A



Main technical indicators

分度号 Pt100:*Ro=100±0.06Ω

B-class Ro=100 ± 0.12 Ω

Range specifications

Model number

graduation mark

Temperature measurement range ℃

accuracy class

Allowable deviation △ t ℃

WZPK

Pt100

-200~500

*

± (0.15 or+0.002 | t |)

Grade B

± (0.3 or+0.005 | t |)


Note: In the formula,'t 'represents the measured temperature value of the temperature sensing element

Nominal Pressure

Generally refers to the ability of the protective tube to withstand static external pressure without rupture at room temperature, and the experimental pressure is generally 1.5 times the nominal pressure. In fact, the allowable nominal pressure is not only related to the material, diameter, and wall thickness of the protective tube, but also to its structural form, installation method, insertion depth, as well as the flow rate and type of the measured medium.

Thermal response time

When there is a step change in temperature, the time required for the output of the thermal resistor to change to 50% of the step change is called the thermal response time, represented by t0.5.

Thermal resistance insulation resistance:

The experimental voltage for insulation resistance at room temperature can take any value from 10 to 100V DC, the ambient temperature should be within the range of 15 to 35 ℃, and the relative humidity should not exceed 80%; The insulation value at room temperature should not be less than 100M Ω.

Thermal resistance allows current to pass through

Measure the maximum current through an armored platinum resistor, which should not exceed 5mA.

Classification types of armored platinum resistors

Outer diameter of armored thermistor (d)


Standard dimensions for installing fixed devices

φ6

φ5

φ4

φ4

φ3

M

M16×1.5

M12×1.5

S

22

19


WZPK2-366SA Armored Thermistor

Outer diameter of armored thermistor (d)


Standard dimensions for installing fixed devices

φ6


φ4

φ4

φ3

D

φ60

φ50

Do

φ42

φ36

D1

φ24

φ20

do

φ9

φ7

S

22

19










Model

Simple terminal

Socket terminal

, length diameter division mark

model

graduation mark

Temperature measurement range ℃

accuracy class

Thermal response time T0.5S

Diameter mm

Length Lmm

Install fixed devices

WZPK-163S

Pt100

-200~500

*

or

Grade B

≤3

φ3

Single length: 100

150

200

250

300

400

500

750

1000




Double branch length:

100

150

200

250

300

400

500


No fixed device

WZPK-164S

≤5

φ4

WZPK-165S

≤8

φ5

WZPK-166S

≤12

φ6

WZPK2-165SA

≤8

φ5

WZPK2-166SA

≤12

φ6

WZPK-263S

≤3

φ3

Fixed card sleeve bolt

WZPK-264S

≤5

φ4

WZPK-265S

≤8

φ5

WZPK-266S

≤12

φ6

WZPK2-265SA

≤8

φ5

WZPK2-266SA

≤12

φ6

WZPK-363S

≤3

φ3

Movable card sleeve bolt

WZPK-364S

≤5

φ4

WZPK-365S

≤8

φ5

WZPK-366S

≤12

φ6

WZPK2-365SA

≤8

φ5

WZPK2366SA

≤12

φ6

WZPK-463S

≤3

φ3

Fixed card sleeve flange

WZPK-464S

≤5

φ4

WZPK-465S

≤8

φ5

WZPK-466S

≤12

φ6

WZPK2-465SA

≤8

φ5

WZPK2466SA

≤12

φ6

WZPK-563S

≤3

φ3

Transportable card sleeve flange

WZPK-564S

≤5

φ4

WZPK-565S

≤8

φ5

WZPK-566S

≤12

φ6

WZPK2-565SA

≤8

φ5

WZPK2566SA

≤12

φ6


Note: 1) Material of protective tube and fixing device: 1Cr18Ni9Ti stainless steel.

2) Double support only produces B-grade products

3) The double branch is a three wire lead system.