PVC J-edge sheathed thermocouple compensation wire

NegotiableUpdate on 12/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
PVC J-edge sheathed thermocouple compensation wire, this product is widely used in measurement departments such as petroleum, chemical, metallurgical, nuclear power plants, power plants, etc. for accurate operation, automation control, temperature measurement, and computer temperature measurement systems. It is equipped with compensation wires for thermocouples with division numbers of S, K, E, J, and T.
Product Details

PVC J-edge sheathed thermocouple compensation wire

Scope of application: This product is widely used in measurement departments such as petroleum, chemical, metallurgical, nuclear power plants, power plants, etc. for accurate operation of automation control, temperature measurement, and computer temperature measurement systems. It is equipped with supplementary wires for thermocouples with division numbers of S, K, E, J, and T.

Product features: According to different harsh environments, different material structures are used to achieve requirements such as fire resistance, oil resistance, acid resistance, alkali resistance, and corrosion resistance.

Main technical parameters

model
SC
KC
KC1
KX
EX
JX
TX
Positive J
red
red
red
red
red
red
red
Negative J
green
blue
Sea Blue
black
brown
purple
white
use
mark
Allow J and protective layer coloring
classification
ambition
Ordinary J
Accurate J
general use
G
(Black)
S (gray)
Heat resistant
H
(Black)
S(******)

PVC J-edge sheathed thermocouple compensation wireCompensate for the thermoelectric potential and allowable deviation of the wire

Thermoelectric potential (standard value)
Humidity of Thermal Power Grid Measurement Station (℃)

100℃
200℃

Thermoelectric potential (standard value)
tolerance
thermoelectric potential
tolerance

Ordinary J
Accurate J (S)
standard value
Ordinary J
Accurate J (S)

SC or RC
645
±60
±30
1440
±60
——
1000
(±5.0℃)
(±2.5℃)
(±5.0℃)
KCA
4095
±100
±60
8137
±100
±60
900
(±2.5℃)
(±1.5℃)
(±2.5℃)
(±1.5℃)
KCB
4095
±100
±60
8137
——
——
900
(±2.5℃)
(±1.5℃)
KX
4095
±100
±60
8137
±100
±60
900
(±2.5℃)
(±1.5℃)
(±2.5℃)
(±1.5℃)
NC
2774
±100
±60
5912
±100
±60
900
(±2.5℃)
(±1.5℃)
(±2.5℃)
(±1.5℃)
NK
2774
±100
±60
5912
±100
±60
900
(±2.5℃)
(±1.5℃)
(±2.5℃)
(±1.5℃)
EX
6317
±200
±120
13419
±200
±120
600
(±2.5℃)
(±1.5℃)
(±2.5℃)
(±1.5℃)
JX
5268
±140
±85
10777
±140
±85
500
(±2.5℃)
(±1.5℃)
(±2.5℃)
(±1.5℃)
TX
4277
±60
±30
9285
±90
±48
30
(±1.0℃)
(±0.5℃)
(±1.5℃)
(±0.8℃)

Compensation wire reciprocating resistance

Compensation wire model
Reciprocating resistance value Ω/m at 20 ℃ (not greater than the following values)
0.2mm2
0.5mm2
1.0mm2
1.5mm2
2.5mm2
SC or RC
0.25
0.1
0.05
0.03
0.02
KCA
3.5
1.4
0.7
0.47
0.28
KCB
2.6
1.04
0.52
0.35
0.21
KX
5.5
2.2
1.1
0.73
0.44
EX
6.25
2.5
1.25
0.83
0.5
JX
3.25
1.3
0.65
0.43
0.26
TX
2.6
1.04
0.52
0.35
0.21
NC
3.75
1.5
0.75
0.5
0.3
NK
7.15
2.86
1.43
0.95
0.57



Thermocouple division number
Compensation wire model
Compensation wire alloy wire M scale
S or R
SC or RC
Copper Copper Nickel 0.6
K
KC
Copper Copper Nickel 40
KX
Nickel chromium 10 nickel silicon 3
N
NC
Iron copper nickel
NX
Nickel chromium silicon nickel chromium magnesium
E
EX
Nickel chromium 10 Copper nickel 45
J
JX
Iron Copper Nickel 45
T
TX
Copper Copper Nickel 45
WRe3/WRe25
WReC
Iron copper nickel


Similar Product Recommend