Temperature range: ambient temperature plus7 ° C to 60 ° C
Humidity range: up to95% relative humidity
optionalO ₂ adjustment range: 0.2-20 Vol. -% O ₂ or 10-95 Vol. -% O ₂ (version O, GO)
pass throughAutomatic sterilization with hot air at 180 ° C
Humidification system for culture dishes with condensation protection
With the Venturi effectCO ₂ mixed gas nozzle
Can be sterilized with hot air using infrared technologyCO ₂ sensor
pass throughDisplay on LCD color monitor
Lockable door handle
Made of safety glassSealed inner door made of ESG
Seamless deep drawn inner cavity made of stainless steel
Made of stainless steel3 perforated shelves
Stackable devices using stacking adapters
Fault diagnosis system using optical and sound alarms
Computer interface: Ethernet
Internal measurement value recording andUSB interface
Zero voltage alarm contact
| name | CB220-230V¹ | CB220-230V-G¹ | CB220-230V-O¹ | CB220-230V-GO¹ | CB220UL-120V¹ | CB220UL-120V-G¹ | CB220UL-120V-O¹ | CB220UL-120V-GO¹ |
| Choose a model | standard | Equipped with a 6-piece detachable inner door | With O ₂ adjustment | Equipped with O ₂ adjustment and 6-piece detachable inner door | standard | Equipped with a 6-piece detachable inner door | With O ₂ adjustment | Equipped with O ₂ adjustment and 6-piece detachable inner door |
| Item code | 9040-0096 | 9040-0108 | 9040-0098 | 9040-0110 | 9040-0097 | 9040-0109 | 9040-0099 | 9040-0111 |
| measure | ||||||||
| Internal volume [L] | 210 | 210 | 210 | 210 | 210 | 210 | 210 | 210 |
| Net weight of equipment (unloaded) [kg] | 121 | 129 | 125 | 132 | 121 | 129 | 125 | 132 |
| Total load [kg] | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 |
| Load per partition [kg] | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
| The dimensions of the casing do not include additional components and connectors | ||||||||
| Net weight width [mm] | 740 | 740 | 740 | 740 | 740 | 740 | 740 | 740 |
| Net weight at height [mm] | 1070 | 1070 | 1070 | 1070 | 1070 | 1070 | 1070 | 1070 |
| Depth net weight [mm] | 715 | 715 | 715 | 715 | 715 | 715 | 715 | 715 |
| Wall to side distance [mm] | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
| Wall distance from rear [mm] | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 |
| Internal dimensions | ||||||||
| Width [mm] | 560 | 560 | 560 | 560 | 560 | 560 | 560 | 560 |
| Height [mm] | 750 | 750 | 750 | 750 | 750 | 750 | 750 | 750 |
| Depth [mm] | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 |
| The number of doors | ||||||||
| Inner door | 1 | 6 | 1 | 6 | 1 | 6 | 1 | 6 |
| Outer door | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
| Data related to the environment | ||||||||
| Energy consumption at 37 ° C [Wh/h] | 120 | 120 | 120 | 120 | 120 | 120 | 120 | 120 |
| firmware | ||||||||
| Number of partitions (hours/) | 3/8 | 3/3 | 3/8 | 3/3 | 3/8 | 3/3 | 3/8 | 3/3 |
| Temperature performance data | ||||||||
| The temperature range exceeds the indoor temperature by 7 ° C to [° C] | 60 | 60 | 60 | 60 | 60 | 60 | 60 | 60 |
| The temperature deviation is 37 ° C [± K] | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 |
| Temperature fluctuation at 37 ° C [± K] | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 |
| The recovery time after opening the door in 30 seconds is 37 ° C [min] | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 |
| Climate performance data | ||||||||
| Humidity range [% relative humidity] | 90…95 | 90…95 | 90…95 | 90…95 | 90…95 | 90…95 | 90…95 | 90…95 |
| CO ₂ data | ||||||||
| CO ₂ range [Vol. -% CO ₂] | 0…20 | 0…20 | 0…20 | 0…20 | 0…20 | 0…20 | 0…20 | 0…20 |
| CO ₂ measurement technology | IR | IR | IR | IR | IR | IR | IR | IR |
| The recovery time of CO ₂ 30 seconds after opening the door is 5 vol. -% CO ₂ [min] | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 |
| Electric data | ||||||||
| Rated voltage [V] | 200…240 | 200…240 | 200…240 | 200…240 | 100…120 | 100…120 | 100…120 | 100…120 |
| Power frequency [Hz] | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
| Rated power [kW] | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 |
| Equipment safety device [A] | 10 | 10 | 10 | 10 | 16 | 16 | 16 | 16 |
| Phase (rated voltage) | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ |
| O ₂ Data | ||||||||
| Standard O ₂ adjustment range: O ₂ range [Vol. -% O ₂] | - | - | 0.2…20 | 0.2…20 | - | - | 0.2…20 | 0.2…20 |
| Optional O ₂ adjustment range: O ₂ range [Vol. -% O ₂] | - | - | 10…95 | 10…95 | - | - | 10…95 | 10…95 |
| The recovery time after opening the door in 30 seconds is 5 vol. -% O ₂ [min] | - | - | 18 | 18 | - | - | 18 | 18 |
1. All technical data is only applicable toStandard specification unloaded equipment under ambient temperature of 22 ± 3 ° C and ± 10% power supply voltage fluctuation. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. We reserve the right to make technical changes.