Welcome Customer !

Membership

Help

Dongguan Yiyunda Lightning Protection Engineering Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Dongguan Yiyunda Lightning Protection Engineering Co., Ltd

  • E-mail

    info@eventu.cn

  • Phone

  • Address

    No. 8, Lane 8, Xinji Second Ring Road, Nancheng District, Dongguan City, Guangdong Province

Contact Now

Power lightning arrester V 20-C, V 20-C...+NPE

NegotiableUpdate on 08/29
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Power lightning arrester V20-C, V20-C

Product Details

Power lightning arrester V 20-C, V 20-C...+NPE

Product description

Characteristic V 20-C Advantages of use
Electric quantity metal oxide varistor Protectors can handle frequent actions and have a long lifespan
Pluggable components The protector module can be tested or replaced by plugging and unplugging with power on
The bases of 1 to 4 pieces have been connected Easy installation through labeled terminals
Thermal circuit breaker and window indicator device
Clear visibility of the working status of the protector
Protector with NPE spark gap module Scope of use (TN-C-S TN-S TT It), structurally safer
C 25-B+C/NPE has reverse insertion protection Simple and professional installation of protector module

Function and application areas

According to the requirements of DIN VDE 0675, Part 6 (Draft 11.89) A1, A2, surge protector V 20-C is a Class C surge protector. It protects electrical equipment from various voltage surges. We can provide different models ranging from single module to 4-module.

The model V 20-C/3+NPE (Class C) is a special surge protector used in TN-C-S, TN-S, TT, and IT systems. This protector is designed according to the new requirements of DIN VDE 0100, Part 534/A1, and achieves simple and safe installation.

V 20-C contains a zinc oxide varistor with high nonlinearity (α>30). This device has the advantages of short response time, low protection level, high flux, and long lifespan, especially when lightning surge passes through the protector, the subsequent current will not occur.

If the surge protector is damaged due to overload, the built-in circuit breaker will promptly activate, interrupting the connection with the power supply, and the color of the fault indication display window will change from green to red.

install

The V 20-C can be easily installed on a 35 mm rail inside any distribution box or switch box. The modules of the multi module protector are already connected by built-in grounding jumpers in the factory, so the protector only needs to be grounded (PE) once. The clever design between NPE protection module C 25-B+C/NPE and the base prevents the module from being inserted in reverse. This ensures the correct installation of the protector module.

Technical Specifications

surge protector
model
V 20-C
75 150 280 320 385 440 550
Maximum continuous operating voltage UC AC
(Maximum allowable operating voltage) UC DC
75 V~
100 V-
150 V~
200 V-
280 V~
350 V-
320 V~
420 V-
385 V~
505 V-
440 V~
585 V-
550 V~
745 V-
Lightning protection zone 0→2
Grade - According to DIN VDE 0675 Part 6 (Draft 11.89) A1, A2
- According to IEC 61643-1

C
grade ii
Test Standard IEC 61643-1,prEN 61643-1,
E DIN VDE 0675-6:1989-11 and Part 6/A1
Nominal discharge current In (8/20) 15 kA

20 kA

15 kA
Overall maximum discharge current Imax (8/20)
V 25-B+C/1
V 25-B+C/2
V 25-B+C/3
V 25-B+C/4

40 kA
75 kA
110 kA
150 kA
maximum discharge current
(Single module) Imax (8/20)

40 kA
voltage protection level
Up at 1 kA (8/20)
Up at 5 kA (8/20)
Up when in
≤300 V
≤350 V
≤500 V
≤500 V
≤650 V
≤800 V
≤900 V
≤1.1 kV
≤1.3kV
≤1.0 kV
≤1.3 kV
≤1.4kV
≤1.2 kV
≤1.5kV
≤1.7 kV
≤1.5 kV
≤1.8kV
≤2.0 kV
≤1.7 kV
≤2.1 kV
≤2.4 kV
Response time TA <25 ns
Maximum backup fuse with short-circuit withstand capacity of 25 kA 125 A gl/gG
Cross sectional area of connecting wire 2.5-25 mm2 (multi strand flexible wire with protective sheath at the connection end)
2.5-35 mm2 (single strand, multi strand wire)
Installation location 35mm guide rail (compliant with EN 50022)
IP level IP 20
Temperature range υ -40 ℃ to+85 ℃
Module NPE
Nominal voltage UC
C 25-B+C/NPE
230 V/50-60 HZ
Insulation resistance Rins at 100V
Surge Voltage Test (10/350) - Lightning Parameters According to IEC 61312-1 (02.95)
Peak current Iimp
Electricity Q
Unit energy W/R
Nominal discharge current In (8/20)
Voltage protection level Up
Response time tA
Subsequent current IF under UC
Temperature range υ
>10 GΩ


25 kA
12.5 As
160 kJ/Ω
50 kA
<1.2 kV
<100 ns
100 Arms
-40 ℃ to+85 ℃
Reserved technical change rights
structural diagram Size chart

1
V 20-C/4

2
3
V 20-C/3+NPE
4