Welcome Customer !

Membership

Help

Dongguan Yiyunda Lightning Protection Engineering Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Dongguan Yiyunda Lightning Protection Engineering Co., Ltd

  • E-mail

    info@eventu.cn

  • Phone

  • Address

    No. 8, Lane 8, Xinji Second Ring Road, Nancheng District, Dongguan City, Guangdong Province

Contact Now

Power lightning arrester V 25-B+C, V 25-B+C...+NPE

NegotiableUpdate on 08/29
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Power lightning arrester V25-B+C, V25-B+C...+NPE product description feature list V25-B+C advantages with marked terminals, easy installation can cope with frequent surge current impact B+C combined protector

Product Details

Power lightning arrester V 25-B+C, V 25-B+C...+NPE

Product description

Characteristic List V 25-B+C Advantages of use
Marked terminals, easy to install Can cope with frequent surge currents
B+C joint protector, applied in situations where the overall space of the building is small Install only one set of protectors inside the main distribution cabinet
Pluggable components After the protector module is damaged, it can be plugged and replaced with power on
Protector base with internal connections, 1 to 4 pieces of base and module numbers Easy to install
Thermal circuit breaker and window indicator device
Clear visibility of the working status of the protector
Protector with NPE spark gap module Widely applicable (suitable for TN, TT, and IT power grids),
Safer structure
V 25-B+C/NPE has reverse insertion protection Ensure simple and professional installation of the protector module

Function and application areas

The lightning surge protector V 25-B+C is a lightning protection equipotential connector designed according to the requirements of VDE 0185, Part 1 and Part 100. This device complies with the requirements of DIN VDE 0675, Part 6 (Draft 11.89) A1, A2 level B+C level protectors. In the installation of lightning protection in buildings, it ensures equipotential connection on power lines. When the power line is overhead and introduced into a building, the overhead line may introduce some direct lightning current. This protector can also be applied to the overhead power line introduced into such a building.

V 25-B+C/3+NPE (B+C grade) can be used for special surge protectors in TN-C-S, TN-S, TT, and IT systems. This protector is designed according to the latest requirements of DIN VDE 0100, Part 534/A1, allowing for simple and safe installation of paired protectors.

The high-performance surge protector OBO V 25-B+C has a special varistor circuit, which contains zinc oxide varistors with good nonlinear characteristics (а>30). Even if there is a high-energy surge in the circuit, the equipment can still receive maximum protection. Even when the surge current reaches 60 kA, the voltage of the protector is still below 1.5 kV. Therefore, the protector can withstand part of the lightning current from direct lightning strikes. In case of overload, the built-in thermal circuit breaker of the protector can disconnect the protector module from the main circuit, ensuring the normal operation of the power supply system. At the same time, the status display window changes from green to red.

The OBO surge protector V 25-B+C can not only withstand lightning currents with high current capacity, but also has the characteristic of low protection voltage, which can be used as a B+C combined protector.

install

The OBO V 25-B+C can be easily installed on a 35 mm rail inside any distribution box or switch box. The clever design between NPE protection module C 25-B+C/NPE and the base prevents the module from being inserted in reverse. This ensures the correct installation of the protector module.

Technical Specifications

B+C-class surge protector
model
V 25-B+C
150 280 385
Maximum continuous operating voltage UC AC
(Maximum allowable operating voltage) UC DC
150 V~
200 V~
280 V~
350V~
385 V~
505 V~
Lightning protection zone 0→2
Grade - According to DIN VDE 0675 Part 6 (Draft 11.89) A1, A2
- According to IEC 61643-1

B+C
Level I → Level II
Test Standard IEC 61643-1,prEN 61643-1,
E DIN VDE 0675-6:1989-11 and Part 6/A1
Test current according to DIN VDE 0675 Part 6 A1+A2
Nominal discharge current In (8/20)

30 kA
Overall maximum discharge current Imax (8/20)
V 25-B+C/1
V 25-B+C/2
V 25-B+C/3
V 25-B+C/4

60 kA
100 kA
150 kA
200 kA
Surge voltage test (10/350) (lightning current parameters set according to IEC 61312-1 (02.95))
Pulse current Iimp
Electricity Q
Unit energy W/R


8 kA
4 As
16 kJ/Ω


7 kA
3.5 As
12 kJ/Ω


7 kA
3.5 As
12 kJ/Ω
Voltage protection level Up at 1 kA (8/20)
Up at 5 kA (8/20)
In Up
≤450 V
≤500 V
≤600 V
≤650 V
≤700 V
≤900 V
≤1.0 kV
≤1.2 kV
≤1.5 kV
Response time TA <25 ns
Maximum backup fuse with short-circuit withstand capacity of 25 kA 60 A gl/gG
Cross sectional area of connecting wire 2.5-25 mm2 (multi strand flexible wire with protective sheath at the connection end)
2.5-35 mm2 (single strand, multi strand wire)
Installation location 35mm guide rail (compliant with EN 50022)
IP level IP 20
Temperature range υ -40 ℃ to+85 ℃
Module NPE
Nominal voltage UN
C 25-B+C/NPE
230 V/50-60 HZ
Insulation resistance Rins at 100V
Surge Voltage Test (10/350) - Lightning Parameters According to IEC 61312-1 (02.95)
Peak current Iimp
Electricity Q
Unit energy W/R
Nominal discharge current In (8/20)
Voltage protection level Up
Response time tA
Subsequent current IF under UC
Temperature range υ
>10 GΩ


25 kA
12.5 As
160 kJ/Ω
50 kA
<1.2 kV
<100 ns
100 Arms
-40 ℃ to+85 ℃
Reserved technical change rights