Welcome Customer !

Membership

Help

Hefei Ultra Pure Instrument Technology Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Hefei Ultra Pure Instrument Technology Co., Ltd

  • E-mail

    479991717@qq.com

  • Phone

    13865908184

  • Address

    No. 2-1203, Xiangxin Chuanggu Industrial Park, Economic Development Zone, Hefei City, Anhui Province

Contact Now

Pure water, ordinary water online pH electrode (sensor)

NegotiableUpdate on 11/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The pure water and ordinary water online pH electrode (sensor) adopts a circular large section Teflon diaphragm imported from Germany. Make the electrode ju have stable liquid contact potential and low resistance characteristics, and prevent blockage and pollution. Using low impedance sensitive glass film and salt ring imported from Germany, effectively eliminating various interferences, increasing ion reserves, fast impact, stability, and long lifespan. Introducing German reference process technology and Dortmund's solution formula. No need to replenish electrolyte. The electrode is suitable for measuring pure water with a conductivity of ≥ 0.1 μ S/cm. PH range 0-13, temperature range 0-80 ℃.

Product Details

5510Pure water electrode (sensor) series

1. Adopt the circular large section Teflon diaphragm imported from Germany. Make the electrode ju have stable liquid contact potential and low resistance characteristics, and prevent blockage and pollution.

2. Adopting low impedance sensitive glass film and salt ring imported from Germany, effectively eliminating various interferences, increasing ion reserves, fast impact, stability, and long lifespan.

3. Introduce German reference process technology and Dortmund's solution formula. No need to replenish electrolyte.

4. The electrode is suitable for measuring pure water with a conductivity of ≥ 0.1 μ S/cm.

5. pH range 0-13, temperature range 0-80 ℃. Pressure range ≤ 0.6Mpa. Zero potential PH=7.00.

6. The external dimensions of the electrode are between 12 and 120 or other sizes.

7. The electrode is mainly suitable for measuring the pH value of pure water treatment series in the thermal power industry.

5510GSTwo composite electrodes

The universal PG13.5 thread installation seal is used, and the outer tube material is glass, which can be directly matched with various pH meters at home and abroad. This electrode is a socket type cable connection.

5510GSTTriple composite electrode

Use universal PG13.5 thread installation seal. The temperature compensation resistor adopts Pt100 and Pt1000 thermistors (to be specified when ordering), and the appearance material is glass. It can be directly used in conjunction with various pH meters both domestically and internationally. This electrode is a socket type cable connection.

5510GFTwo composite electrodes

The universal PG13.5 thread installation seal is used, and the outer tube material is glass, which can be directly matched with various pH meters at home and abroad. This electrode is a fixed cable connection, and the length of the wire is according to the user's requirements.

5510GFTTwo composite electrodes

The universal PG13.5 thread installation seal is used, and the temperature compensation resistor adopts PT100, PT1000 or thermistor (to be specified when ordering). The outer tube material is glass. It can be directly used in conjunction with various pH meters both domestically and internationally. This electrode is a fixed cable connection. The length of the wire shall be in accordance with the user's requirements.

5510BKTriple composite electrode

Adopting a rotating card installation seal. The temperature compensation resistor adopts Pt100 and Pt1000 thermistors (to be specified when ordering), with a plastic outer tube and external dimensionsF26.7× 145.This electrode is a fixed cable connection. The length of the wire shall be in accordance with the user's requirements.

5510SKTriple composite electrode

Adopting a rotating card installation seal. The temperature compensation resistor adopts Pt100 and Pt1000 thermistors (to be specified when ordering), with a plastic outer tube and external dimensionsF26.7× 145.This electrode is a socket type cable connection.

5510BPTriple composite electrode

Use a middle nut to tighten and install the seal. The fixed cable connection and wire length shall be in accordance with the user's requirements. The temperature compensation resistor shall be Pt100 or Pt1000 thermistor (to be specified when ordering), with a plastic outer tube.

5110BNTTriple composite electrode:

Using 3/4NPT thread installation seal, fixing cable connection, plastic outer tube, external dimensions of Ø 26.7 × 168.4, wire length according to user requirements. The temperature compensation resistor adopts Pt100 and Pt1000 thermistors (to be specified when ordering). The installation methods include submerged and flow-through, and can be directly matched with various pH meters at home and abroad.

5110SCTwo composite electrodes:

This electrode is suitable for high purity water measurement (≤ 0.1 μ S/cm) or occasions where solid electrolyte gel filling is not suitable (such as high concentration organic solvent, viscous medium, etc.). Adopting universal PG13.5 thread installation seal, imported ceramic diaphragm, liquid KCL filling, can be connected to an external container with reverse pressure and liquid filling, socket type cable connection, and the outer pipe material is glass. It can be directly used in conjunction with various pH meters both domestically and internationally.

5520Ordinary water series

1. Adopt the circular large section Teflon diaphragm imported from Germany. Make the electrode ju have stable liquid contact potential and low resistance characteristics, and prevent blockage and pollution.

2. Introduce German reference process technology. Unique solution formula. Resistant to strong acids, strong alkalis, and no supplementary electrolyte. Electrode response is fast, stable, and has a long service life. Built in salt bridge can better prevent electrodes from being subjected to S2-CN-Plasma erosion.

3. The motor is mainly designed for pH measurement of general pure water, industrial water, and sewage.

4. pH range 0-14, temperature range 0-80 ℃, pressure range ≤ 0.6MPa, zero point pH=7.00

5. The external dimensions of the electrode range from 12 to 120, 150, 225, or other sizes.

5520GSTwo composite electrodes

Universal PG13.5 thread installation seal is used, with glass outer tube material and socket type cable connection. It can be directly used in conjunction with various pH meters both domestically and internationally.

5520GSTTriple composite electrode

Use universal PG13.5 thread installation seal. The temperature compensation resistor adopts Pt100 and Pt1000 thermistors (to be specified when ordering), and the appearance material is glass. It can be directly used in conjunction with various pH meters both domestically and internationally. This electrode is a socket type cable connection.

5520GFTwo composite electrodes

Universal PG13.5 thread installation seal is used, with glass outer tube material, fixed cable connection, and wire length according to user requirements. It can be directly used in conjunction with various pH meters both domestically and internationally.

5520GFTTriple composite electrode

Universal PG13.5 thread installation seal is used, and temperature compensation resistors are PT100, PT1000, or thermistor (to be specified when ordering). The outer tube material is glass. It can be directly used in conjunction with various pH meters both domestically and internationally. This electrode is a fixed cable connection. The length of the wire shall be in accordance with the user's requirements.

5520BNTwo composite electrodes

Install the seal using 3/4NPT pipe threads. Fixed cable connection. Plastic outer tube, with dimensions of Ø 26.7 × 168.4 and wire length according to user requirements. There are two installation methods: submerged and flow-through. It can be directly used in conjunction with various pH meters both domestically and internationally.

552OBNTTriple composite electrode

Install the seal using 3/4NPT pipe threads. Fixed cable connection. Plastic outer tube, with dimensions of Ø 26.7 × 168.4 and wire length according to user requirements. The temperature compensation resistor adopts Pt100 and Pt1000 thermistors (to be specified when ordering), and the installation methods include submerged and flow-through. It can be directly used in conjunction with various pH meters both domestically and internationally.

5530Hydrogen resistant acid series

1. Adopt the circular large section Teflon diaphragm imported from Germany. Make the electrode ju have stable liquid contact potential and low resistance characteristics, and prevent blockage and pollution.

2. Introduce German reference process technology. Unique solution formula. Resistant to strong acids, strong alkalis, and no supplementary electrolyte. The electrode affects the express. Stable and long service life. Using foreign plastic sensitive film, the internal resistance is extremely low (<0.1M Ω, thereby reducing the requirement for the input impedance of the secondary meter when clicked).

3. The motor is mainly designed for pH measurement in media containing hydrogen and acid.

4. pH range 0-13, temperature range 0-60 ℃, pressure range ≤ 0.6MPa, zero point pH=7.00

5. The external dimensions of the electrode are between 12 and 120, 150 or other sizes.

5530GSTwo composite electrodes

Universal PG13.5 thread installation seal is used, made of glass material. It can be directly used in conjunction with various pH meters both domestically and internationally.

5530GFTwo composite electrodes

Universal PG13.5 thread installation seal is used, with glass outer tube material, fixed cable connection, and wire length according to user requirements. It can be directly used in conjunction with various pH meters both domestically and internationally.

5530BNTwo composite electrodes

Using 3/4NPT thread installation seal, fixing cable connection, plastic outer tube, external dimensions of Ø 26.7 × 168.4 wire length according to user requirements. The installation methods include sinking and circulating, which can be directly matched with various pH meters at home and abroad.

5530BNTTriple composite electrode

Using 3 4NPI thread installation seal, fixing cable connection, plastic outer tube, external dimensions of Ø 26.7 × 168.4 wire length according to user requirements. The temperature compensation resistor adopts Pt100 and Pt1000 thermistors (to be specified when ordering). The installation methods include submerged and flow-through, and can be directly matched with various pH meters at home and abroad.