Welcome Customer !

Membership

Help

Dongguan Yiyunda Lightning Protection Engineering Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Dongguan Yiyunda Lightning Protection Engineering Co., Ltd

  • E-mail

    info@eventu.cn

  • Phone

  • Address

    No. 8, Lane 8, Xinji Second Ring Road, Nancheng District, Dongguan City, Guangdong Province

Contact Now

SD and ASP series data dedicated line surge protectors

NegotiableUpdate on 10/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

SD and ASP series data dedicated line surge protectors Product description Performance SD

Product Details

SD and ASP series data dedicated line surge protectors


Product description
Performance SD, ASP data dedicated line surge protector Advantages of use
Standard Interface (SD Series) Quick and easy installation
The metal interface has been grounded (SD series) No need to install additional grounding wires
Unscrew crimping port (ASP series) Quick and professional installation

Function and application areas

SD series: The SD series lightning arrester is used to protect communication devices with Class D interfaces (such as computers, communication buses, etc.). The internal bidirectional diode quickly responds to overvoltage and limits it to a harmless level.

ASP series: mainly used as surge protectors in two-wire or four wire communication series, with internal fast box diodes to ensure that connected devices are not affected by surges.

install

Sd series: Connect the surge protector of the corresponding interface directly in series with the interface of the protected device.

ASP series: It does not require screw fastening and can be directly installed in series on the protected equipment. The protected wire is pressed directly into the connection hole, and the grounding of the protector is as short as possible. The grounding wire is directly connected to the protective grounding of the protected equipment.

Technical Specifications

Sd interface surge protector SD09-
V24/9
SD15-
V24/15
SD25-
V24/25
SD09-
V11/9
SD15-
V11/15
Working voltage UN
Action voltage UC
LPZ area

Maximum discharge current Imax
Response time tA
parasitic capacitance
12V
18V
2→3
Pin1-9
340A
<10 ns
<30 pF
(>40 M Porter)
12V
18V
2→3
Pin1-15
340A
<10 ns
<30 pF
(>40 M Porter)
12V
18V
2→3
Pin1-25
340A
<10 ns
<30 pF
(>40 M Porter)
6V
7.5V
2→3
Pin1-9
750A
<10 ns
<30 pF
(>40 M Porter)
6V
7.5V
2→3
Pin1-15
750A
<10 ns
<30 pF
(>40 M Porter)

Sd interface surge protector SD25-
V11/25
SD09-T SD15E SD36-
C/MF
SD25-
Parallel
Working voltage UN
Action voltage UC
LPZ area

Maximum discharge current Imax
Response time tA
parasitic capacitance
6V
7.5V
2→3
Pin1-25
750A
<10 ns
<30 pF
(>40 M Porter)
12V
18V
2→3
Pin1-9
340A
<10 ns
<30 pF
(>40 M Porter)
5V/12V
7.5v/18V
2→3
Pin1-15
750A
<10 ns
<30 pF
(>40 M Porter)
6V
7.5V
2→3
Pin1-36
750A
<10 ns
<30 pF
(>40 M Porter)
6V
7.5V
2→3
Pin1-25
750A
<10 ns
<30 pF
(>40 M Porter)

ASP interface surge protector ASP-V24T/4
ASP-V11EI/4
ASP-Tele/2
Working voltage UN
Action voltage UC
LPZ area
Number of protection cores
Maximum discharge current Imax
Response time tA
parasitic capacitance
12V
18V
2→3
4
340A
<10 ns
<40 pF
6V
7.5V
2→3
4
750A
<10 ns
<40 pF
110V
240V
2→3
2
250A
<10 ns
<40 pF